메뉴 건너뛰기




Volumn 53, Issue 5, 2006, Pages 900-911

Frequency division transmission imaging and synthetic aperture reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

EXCITATION WAVEFORMS; FREQUENCY MODULATED SIGNALS; MATCHED FILTER; PENETRATION DEPTH; SYNTHETIC TRANSMIT APERTURE (STA);

EID: 33744769108     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2006.1632681     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 0019902876 scopus 로고
    • A real-time synthetic aperture digital acoustic imaging system
    • P. Alais and A. F. Metherell, Eds.
    • S. Bennett, D. K. Peterson, D. Corl, and G. S. Kino, "A real-time synthetic aperture digital acoustic imaging system," in Proc. 10th Int. Symp. Acoust. Imag., vol. 10, P. Alais and A. F. Metherell, Eds. 1982, pp. 669-692.
    • (1982) Proc. 10th Int. Symp. Acoust. Imag. , vol.10 , pp. 669-692
    • Bennett, S.1    Peterson, D.K.2    Corl, D.3    Kino, G.S.4
  • 4
    • 0026866582 scopus 로고
    • Coded excitation system for improving the penetration of real-time phased-array imaging systems
    • M. O'Donnell, "Coded excitation system for improving the penetration of real-time phased-array imaging systems," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, pp. 341-351, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.39 , pp. 341-351
    • O'Donnell, M.1
  • 6
    • 0034579635 scopus 로고    scopus 로고
    • Clinical use and evaluation of coded excitation in B-mode images
    • T. X. Misaridis, M. H. Pedersen, and J. A. Jensen, "Clinical use and evaluation of coded excitation in B-mode images," in Proc. IEEE Ultrason. Symp., 2000, pp. 1689-1693.
    • (2000) Proc. IEEE Ultrason. Symp. , pp. 1689-1693
    • Misaridis, T.X.1    Pedersen, M.H.2    Jensen, J.A.3
  • 7
    • 0033294969 scopus 로고    scopus 로고
    • An effective coded excitation scheme based on a predistorted FM signal and an optimized digital filter
    • T. X. Misaridis and J. A. Jensen, "An effective coded excitation scheme based on a predistorted FM signal and an optimized digital filter," in Proc. IEEE Ultrason. Symp., 1999, pp. 1589-1593.
    • (1999) Proc. IEEE Ultrason. Symp. , pp. 1589-1593
    • Misaridis, T.X.1    Jensen, J.A.2
  • 8
    • 0003607019 scopus 로고    scopus 로고
    • Ph.D. dissertation, Ørsted·DTU, Technical University of Denmark, Lyngby, Denmark
    • T. Misaridis, "Ultrasound imaging using coded signals," Ph.D. dissertation, Ørsted·DTU, Technical University of Denmark, Lyngby, Denmark, 2001.
    • (2001) Ultrasound Imaging Using Coded Signals
    • Misaridis, T.1
  • 9
    • 0026868890 scopus 로고
    • Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging
    • M. O'Donnell and L. J. Thomas, "Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, pp. 366-380, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.39 , pp. 366-380
    • O'Donnell, M.1    Thomas, L.J.2
  • 11
    • 0030196861 scopus 로고    scopus 로고
    • A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics
    • C. Passmann and H. Ermert, "A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, pp. 545-552, 1996.
    • (1996) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.43 , pp. 545-552
    • Passmann, C.1    Ermert, H.2
  • 13
    • 0036032882 scopus 로고    scopus 로고
    • Multi-element synthetic transmit aperture imaging using temporal encoding
    • K. L. Gammelmark and J. A. Jensen, "Multi-element synthetic transmit aperture imaging using temporal encoding," in Proc. SPIE: Prog. Biomed. Opt. Imag., 2002, vol. 3, pp. 25-36.
    • (2002) Proc. SPIE: Prog. Biomed. Opt. Imag. , vol.3 , pp. 25-36
    • Gammelmark, K.L.1    Jensen, J.A.2
  • 14
    • 85047688862 scopus 로고    scopus 로고
    • Multielement synthetic transmit aperture imaging using temporal encoding
    • K. L. Gammelmark and J. A. Jensen, "Multielement synthetic transmit aperture imaging using temporal encoding," IEEE Trans. Med. Imag., vol. 22, no. 4, pp. 552-563, 2003.
    • (2003) IEEE Trans. Med. Imag. , vol.22 , Issue.4 , pp. 552-563
    • Gammelmark, K.L.1    Jensen, J.A.2
  • 17
    • 0036566653 scopus 로고    scopus 로고
    • Space-time encoding for high frame rate ultrasound imaging
    • T. Misaridis and J. A. Jensen, "Space-time encoding for high frame rate ultrasound imaging," Ultrasonics, vol. 40, pp. 593-597, 2002.
    • (2002) Ultrasonics , vol.40 , pp. 593-597
    • Misaridis, T.1    Jensen, J.A.2
  • 18
    • 84980029307 scopus 로고    scopus 로고
    • Synthetic transmit aperture using orthogonal golay coded excitation
    • R. Y. Chiao and L. J. Thomas, "Synthetic transmit aperture using orthogonal golay coded excitation," in Proc. IEEE Ultrason. Symp., 2000, pp. 1469-1472.
    • Proc. IEEE Ultrason. Symp. , vol.2000 , pp. 1469-1472
    • Chiao, R.Y.1    Thomas, L.J.2
  • 20
    • 0026838720 scopus 로고
    • Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
    • J. A. Jensen and N. B. Svendsen, "Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, pp. 262-267, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.39 , pp. 262-267
    • Jensen, J.A.1    Svendsen, N.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.