메뉴 건너뛰기




Volumn 5, Issue 27, 2004, Pages 33-43

Preliminary in-vivo evaluation of convex array synthetic aperture imaging

Author keywords

Clinical evaluation; Image comparison; Medical ultrasound; Synthetic aperture imaging

Indexed keywords

COMPUTER SIMULATION; DATA ACQUISITION; ESTIMATION; IMAGE QUALITY; IMAGING TECHNIQUES; MEDICAL IMAGING; OPTICAL RESOLVING POWER; SCANNING; SIGNAL TO NOISE RATIO; THREE DIMENSIONAL; ULTRASONIC TRANSDUCERS; ULTRASONICS;

EID: 12144250692     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.535084     Document Type: Conference Paper
Times cited : (12)

References (14)
  • 2
    • 0036996095 scopus 로고    scopus 로고
    • Experimental study of convex coded synthetic transmit aperture imaging
    • K. L. Gammelmark and J. A. Jensen, "Experimental study of convex coded synthetic transmit aperture imaging," in Proc. IEEE Ultrason. Symp., pp. 1573-1576, 2002.
    • (2002) Proc. IEEE Ultrason. Symp. , pp. 1573-1576
    • Gammelmark, K.L.1    Jensen, J.A.2
  • 3
    • 85047688862 scopus 로고    scopus 로고
    • Multielement synthetic transmit aperture imaging using temporal encoding
    • K. L. Gammelmark and J. A. Jensen, "Multielement synthetic transmit aperture imaging using temporal encoding," IEEE Trans. Med. Imag. 22(4), pp. 552-563, 2003.
    • (2003) IEEE Trans. Med. Imag. , vol.22 , Issue.4 , pp. 552-563
    • Gammelmark, K.L.1    Jensen, J.A.2
  • 4
    • 0026868890 scopus 로고
    • Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging
    • M. O'Donnell and L. J. Thomas, "Efficient synthetic aperture imaging from a circular aperture with possible application to catheter-based imaging," IEEE Trans. Ultrason., Ferroelec., Freq. Contr. 39, pp. 366-380, 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelec., Freq. Contr. , vol.39 , pp. 366-380
    • O'Donnell, M.1    Thomas, L.J.2
  • 5
    • 0033294969 scopus 로고    scopus 로고
    • An effective coded excitation scheme based on a predistorted FM signal and an optimized digital filter
    • T. X. Misaridis and J. A. Jensen, "An effective coded excitation scheme based on a predistorted FM signal and an optimized digital filter," in Proc. IEEE Ultrason. Symp., 2, pp. 1589-1593, 1999.
    • (1999) Proc. IEEE Ultrason. Symp. , vol.2 , pp. 1589-1593
    • Misaridis, T.X.1    Jensen, J.A.2
  • 7
    • 0003978799 scopus 로고    scopus 로고
    • Information for manufacturers seeking marketing clearance of diagnostic ultrasound systems and transducers
    • Center for Devices and Radiological Health, United States Food and Drug Administration
    • PDA, "Information for manufacturers seeking marketing clearance of diagnostic ultrasound systems and transducers," tech. rep., Center for Devices and Radiological Health, United States Food and Drug Administration, 1997.
    • (1997) Tech. Rep.
  • 8
    • 0003955854 scopus 로고    scopus 로고
    • Acoustic output measurement standard for diagnostic ultrasound equipment
    • American Institute of Ultrasound in Medicine & National Electrical Manufacturers Association, May
    • AIUM, "Acoustic output measurement standard for diagnostic ultrasound equipment," tech. rep., American Institute of Ultrasound in Medicine & National Electrical Manufacturers Association, May 1998.
    • (1998) Tech. Rep.
  • 9
    • 0037972744 scopus 로고    scopus 로고
    • Clinical evaluation of chirp-coded excitation in medical ultrasound
    • M. H. Pedersen, T. X. Misaridis, and J. A. Jensen, "Clinical evaluation of chirp-coded excitation in medical ultrasound," Ultrasound Med. Biol. 29(6), pp. 895-905, 2003.
    • (2003) Ultrasound Med. Biol. , vol.29 , Issue.6 , pp. 895-905
    • Pedersen, M.H.1    Misaridis, T.X.2    Jensen, J.A.3
  • 11
    • 4143057975 scopus 로고    scopus 로고
    • Duplex synthetic aperture imaging with tissue motion compensation
    • K. L. Gammelmark and J. A. Jensen, "Duplex synthetic aperture imaging with tissue motion compensation," in Proc. IEEE Ultrason. Symp., pp. 1569-1573, 2003.
    • (2003) Proc. IEEE Ultrason. Symp. , pp. 1569-1573
    • Gammelmark, K.L.1    Jensen, J.A.2
  • 12
    • 4143114898 scopus 로고    scopus 로고
    • Further development of synthetic aperture real-time 3d scanning with a rotating phased array
    • S. I. Nikolov, B. Tomov, F. Gran, R. Dufait, and J. A. Jensen, "Further development of synthetic aperture real-time 3d scanning with a rotating phased array," in Proc. IEEE Ultrason. Symp., pp. 1899-1902, 2003.
    • (2003) Proc. IEEE Ultrason. Symp. , pp. 1899-1902
    • Nikolov, S.I.1    Tomov, B.2    Gran, F.3    Dufait, R.4    Jensen, J.A.5
  • 13
    • 0032636279 scopus 로고    scopus 로고
    • Theoretical assessment of a synthetic aperture beamformer for real-time 3-D imaging
    • C. R. Hazard and G. R. Lockwood, "Theoretical assessment of a synthetic aperture beamformer for real-time 3-D imaging," IEEE Trans. Ultrason., Ferroelec., Freq. Contr. 46, pp. 972-980, 1999.
    • (1999) IEEE Trans. Ultrason., Ferroelec., Freq. Contr. , vol.46 , pp. 972-980
    • Hazard, C.R.1    Lockwood, G.R.2
  • 14
    • 4143142414 scopus 로고    scopus 로고
    • A method for real-time three-dimensional vector velocity imaging
    • J. A. Jensen and S. I. Nikolov, "A method for real-time three-dimensional vector velocity imaging," in Proc. IEEE Ultrason. Symp., pp. 1582-1585, 2003.
    • (2003) Proc. IEEE Ultrason. Symp. , pp. 1582-1585
    • Jensen, J.A.1    Nikolov, S.I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.