메뉴 건너뛰기




Volumn 9, Issue 3, 2006, Pages 263-266

The effect of performance feedback on cardiorespiratory fitness field tests

Author keywords

Agreement; Field test; Shuttle run test; Square shuttle test; Verbal cues

Indexed keywords

ACCURACY; ADULT; ANALYSIS OF VARIANCE; ARTICLE; AUDITORY STIMULATION; CARDIOPULMONARY FUNCTION; CONTROLLED STUDY; CORRELATION ANALYSIS; EXERCISE TEST; FEEDBACK SYSTEM; HUMAN; MALE; NORMAL HUMAN; OXYGEN CONSUMPTION; PHYSICAL PERFORMANCE; PREDICTION; TREADMILL EXERCISE;

EID: 33744521745     PISSN: 14402440     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jsams.2006.03.027     Document Type: Article
Times cited : (16)

References (6)
  • 2
    • 16244418095 scopus 로고    scopus 로고
    • Enhancing specificity in proxy-design for the assessment of bioenergetics
    • Flouris A.D., Koutedakis Y., Nevill A., et al. Enhancing specificity in proxy-design for the assessment of bioenergetics. J Sci Med Sport 7 (2004) 197-204
    • (2004) J Sci Med Sport , vol.7 , pp. 197-204
    • Flouris, A.D.1    Koutedakis, Y.2    Nevill, A.3
  • 3
    • 0024635623 scopus 로고
    • Validity of the 20 m shuttle run test with 1 min stages to predict maximal oxygen uptake in adults
    • Léger L., and Gadoury C. Validity of the 20 m shuttle run test with 1 min stages to predict maximal oxygen uptake in adults. Can J Sport Sci 14 (1989) 21-26
    • (1989) Can J Sport Sci , vol.14 , pp. 21-26
    • Léger, L.1    Gadoury, C.2
  • 4
    • 0033047413 scopus 로고    scopus 로고
    • A modified incremental shuttle run test for the determination of peak shuttle running speed and the prediction of maximal oxygen uptake
    • Wilkinson D., Fallowfield J., and Myers S. A modified incremental shuttle run test for the determination of peak shuttle running speed and the prediction of maximal oxygen uptake. J Sports Sci 17 (1999) 413-419
    • (1999) J Sports Sci , vol.17 , pp. 413-419
    • Wilkinson, D.1    Fallowfield, J.2    Myers, S.3
  • 5
    • 0030697403 scopus 로고    scopus 로고
    • Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science
    • Nevill A.M., and Atkinson G. Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science. Br J Sports Med 31 (1997) 314-318
    • (1997) Br J Sports Med , vol.31 , pp. 314-318
    • Nevill, A.M.1    Atkinson, G.2
  • 6
    • 0026039735 scopus 로고
    • Factors influencing assessment of maximal heart rate
    • Ingier F. Factors influencing assessment of maximal heart rate. Scand J Med Sci Sports 1 (1991) 134-140
    • (1991) Scand J Med Sci Sports , vol.1 , pp. 134-140
    • Ingier, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.