Volumn 37, Issue 6, 2006, Pages 347-351

Validating new reagents: Roadmaps through the wilderness

Author keywords

[No Author keywords available]

Indexed keywords

REAGENT;

EID: 33744503665     PISSN: 00075027     EISSN: None     Source Type: Journal    
DOI: 10.1309/BRC6Y37NM3BU97WX     Document Type: Article
Times cited : (11)

References (13)
  • 1
    • 0031060088 scopus 로고    scopus 로고
    • Intrepretive criteria and quality control parameters for testing of susceptibilities of Haemophilus influenzae and Streptococcus pneumoniae to trimethoprim and trimethoprim-sulfamethoxazole
    • Fuchs PC, Barry AL, Brown SD, et al. Intrepretive criteria and quality control parameters for testing of susceptibilities of Haemophilus influenzae and Streptococcus pneumoniae to trimethoprim and trimethoprim-sulfamethoxazole. J Clin Microbiol. 1997;35:125-131.
    • (1997) J Clin Microbiol , vol.35 , pp. 125-131
    • Fuchs, P.C.1    Barry, A.L.2    Brown, S.D.3
  • 2
    • 0026018072 scopus 로고
    • Warning: Simplate II, lack of standardization in standardized bleeding time devices-reply: Lot-to-lot variation in ejection force has been rectified
    • Houdijk WP. Warning: Simplate II, lack of standardization in standardized bleeding time devices-reply: Lot-to-lot variation in ejection force has been rectified. Thromb Haemost. 1991;66:625-626.
    • (1991) Thromb Haemost , vol.66 , pp. 625-626
    • Houdijk, W.P.1
  • 3
    • 0026247989 scopus 로고
    • COULTER lyse S III diff: Reagent lot gives erroneous results
    • Anonymous. COULTER lyse S III diff: Reagent lot gives erroneous results. Health Devices. 1991;20:445-446.
    • (1991) Health Devices , vol.20 , pp. 445-446
  • 4
    • 0026465473 scopus 로고
    • Between-lot/between-instrument variations of the Abbott IMx method for prostate-specific antigen
    • Carey RN, Frye RM, Cook JD, et al. Between-lot/between-instrument variations of the Abbott IMx method for prostate-specific antigen. Clin Chem. 1992;38:2341-2343.
    • (1992) Clin Chem , vol.38 , pp. 2341-2343
    • Carey, R.N.1    Frye, R.M.2    Cook, J.D.3
  • 5
    • 0028884909 scopus 로고
    • Variation in measurement of prostate-specific antigen: Importance of method and lot variability
    • Wener MH, Daum PR, Brawer MK. Variation in measurement of prostate-specific antigen: importance of method and lot variability. Clin Chem. 1995;41:1730-1737.
    • (1995) Clin Chem , vol.41 , pp. 1730-1737
    • Wener, M.H.1    Daum, P.R.2    Brawer, M.K.3
  • 6
    • 2142696591 scopus 로고    scopus 로고
    • Lot-to-lot variation in anti-hepatitis C signal-to-cutoff ratio
    • Dufour DR. Lot-to-lot variation in anti-hepatitis C signal-to-cutoff ratio. Clin Chem. 2004;50:958-960.
    • (2004) Clin Chem , vol.50 , pp. 958-960
    • Dufour, D.R.1
  • 7
    • 0027336930 scopus 로고
    • Assessment of the Abbott IMx assay system for the measurement of human chorionic gonadotropin levels in the treatment of ectopic pregnancy
    • Goodman DB, Bulley M, Hendricks M, et al. Assessment of the Abbott IMx assay system for the measurement of human chorionic gonadotropin levels in the treatment of ectopic pregnancy. Arch Pathol Lab Med. 1993;117:701-703.
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 701-703
    • Goodman, D.B.1    Bulley, M.2    Hendricks, M.3
  • 9
    • 84942966558 scopus 로고
    • Multicentre evaluation of a non-wipe system for the rapid determination of total cholesterol in capillary blood. Accutrend cholesterol on Accutrend GC
    • Gottschling HD, Reuter W, Ronquist G, et al. Multicentre evaluation of a non-wipe system for the rapid determination of total cholesterol in capillary blood. Accutrend cholesterol on Accutrend GC. Eur J Clin Chem Clin Biochem. 1995;33:373-381.
    • (1995) Eur J Clin Chem Clin Biochem , vol.33 , pp. 373-381
    • Gottschling, H.D.1    Reuter, W.2    Ronquist, G.3
  • 10
    • 0023749701 scopus 로고
    • Use of the Reflotron system for cholesterol assay in capillary blood, venous blood, and serum-evaluation of accuracy and lot-to-lot reagent comparability
    • Boerma GJ, Gelderland J, van Gorp I, et al. Use of the Reflotron system for cholesterol assay in capillary blood, venous blood, and serum-evaluation of accuracy and lot-to-lot reagent comparability. Clin Chem. 1988;34:2117-2119.
    • (1988) Clin Chem , vol.34 , pp. 2117-2119
    • Boerma, G.J.1    Gelderland, J.2    Van Gorp, I.3
  • 11
    • 0025279617 scopus 로고
    • The significance of matrix effects on the measurement of lactate dehydrogenase (LD) activity using Kodak dry slide technology in the Ontario Laboratory Proficiency Testing Program
    • Hill SA, Heathcote JC, McQueen MJ. The significance of matrix effects on the measurement of lactate dehydrogenase (LD) activity using Kodak dry slide technology in the Ontario Laboratory Proficiency Testing Program. Clin Biochem. 1990;23:179-181.
    • (1990) Clin Biochem , vol.23 , pp. 179-181
    • Hill, S.A.1    Heathcote, J.C.2    McQueen, M.J.3
  • 12
    • 10144241516 scopus 로고
    • Federal Register Friday February 28
    • Department of Health & Human Services Health Care Financing Administration Public Health Service 42 CFR Part 405, et al. Clinical Laboratory Improvement Amendments of 1988; final rule. Federal Register Friday February 28, 1992.
    • (1992) Clinical Laboratory Improvement Amendments of 1988; Final Rule
  • 13
    • 0033369894 scopus 로고    scopus 로고
    • Current databases on biologic variation: Pros, cons and progress
    • Ricos C, Alvarez V, Cava F, et al. Current databases on biologic variation: pros, cons and progress. Scand J Clin Lab Invest. 1999;59:491-500. (updated in http://www.westgard.com/biodatabase1.htm)
    • (1999) Scand J Clin Lab Invest , vol.59 , pp. 491-500
    • Ricos, C.1    Alvarez, V.2    Cava, F.3