메뉴 건너뛰기




Volumn 35, Issue 4, 2006, Pages 398-405

Mechanical evaluation of pin and tension-band wire factors in an olecranon osteotomy model

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ANIMAL DISEASE; ARTICLE; AUDIOVISUAL EQUIPMENT; BIOMECHANICS; DOG; EVALUATION; HUMERUS FRACTURE; INJURY; INSTRUMENTATION; KIRSCHNER WIRE; OSTEOSYNTHESIS; OSTEOTOMY; TENSILE STRENGTH;

EID: 33744495757     PISSN: 01613499     EISSN: 1532950X     Source Type: Journal    
DOI: 10.1111/j.1532-950X.2006.00164.x     Document Type: Article
Times cited : (16)

References (33)
  • 1
    • 0022308950 scopus 로고
    • Complication of tension-band wiring of olecranon fractures
    • Macko D Szabo RM : Complication of tension-band wiring of olecranon fractures. J Bone Joint Surg Am 67 : 1396 1401, 1985
    • (1985) J Bone Joint Surg Am , vol.67 , pp. 1396-1401
    • MacKo, D.1    Szabo, R.M.2
  • 2
    • 0023110649 scopus 로고
    • Intra-articular distal humerus fracture in adults
    • Henley MB : Intra-articular distal humerus fracture in adults. Orthop Clin North Am 18 : 11 23, 1987
    • (1987) Orthop Clin North Am , vol.18 , pp. 11-23
    • Henley, M.B.1
  • 3
    • 0023514940 scopus 로고
    • Displaced olecranon fractures in adults. Clinical evaluation
    • Murphy DF Greene WB Dameron TB Jr.. : Displaced olecranon fractures in adults. Clinical evaluation. Clin Orthop 224 : 215 223, 1987
    • (1987) Clin Orthop , vol.224 , pp. 215-223
    • Murphy, D.F.1    Greene, W.B.2    Dameron Jr., T.B.3
  • 4
    • 0026467239 scopus 로고
    • Olecranon fractures. a clinical and radiographic comparison of tension band wiring and plate fixation
    • Hume MC Wiss DA : Olecranon fractures. A clinical and radiographic comparison of tension band wiring and plate fixation. Clin Orthop 285 : 229 235, 1992
    • (1992) Clin Orthop , vol.285 , pp. 229-235
    • Hume, M.C.1    Wiss, D.A.2
  • 5
    • 0024115578 scopus 로고
    • A combined tension band and lag screw technique for fixation of olecranon osteotomies
    • Palmer RH Aron DN Chambers JN : A combined tension band and lag screw technique for fixation of olecranon osteotomies. Vet Surg 17 : 328 332, 1988
    • (1988) Vet Surg , vol.17 , pp. 328-332
    • Palmer, R.H.1    Aron, D.N.2    Chambers, J.N.3
  • 6
    • 0036304503 scopus 로고    scopus 로고
    • Complication rate and factors affecting outcome of olecranon osteotomies repaired with pin and tension-band fixation in dogs
    • Halling KB Lewis DD Cross AR, et al : Complication rate and factors affecting outcome of olecranon osteotomies repaired with pin and tension-band fixation in dogs. Can Vet J 43 : 528 534, 2002
    • (2002) Can Vet J , vol.43 , pp. 528-534
    • Halling, K.B.1    Lewis, D.D.2    Cross, A.R.3
  • 7
    • 0021958564 scopus 로고
    • Methods of fixation of olecranon fractures. An experimental mechanical study
    • Fyfe IS Mossad MM Holdsworth BJ : Methods of fixation of olecranon fractures. An experimental mechanical study. J Bone Joint Surg Br 67 : 367 372, 1985
    • (1985) J Bone Joint Surg Br , vol.67 , pp. 367-372
    • Fyfe, I.S.1    Mossad, M.M.2    Holdsworth, B.J.3
  • 8
    • 0024467791 scopus 로고
    • Analysis of mechanical factors affecting fixation of olecranon fractures
    • Horner SR Sadasivan KK Lipka JM, et al : Analysis of mechanical factors affecting fixation of olecranon fractures. Orthopedics 12 : 1469 1472, 1989
    • (1989) Orthopedics , vol.12 , pp. 1469-1472
    • Horner, S.R.1    Sadasivan, K.K.2    Lipka, J.M.3
  • 9
    • 0038333636 scopus 로고    scopus 로고
    • Cyclic loading of olecranon fracture fixation constructs
    • Hutchinson DT Horwitz DS Ha G, et al : Cyclic loading of olecranon fracture fixation constructs. J Bone Joint Surg Am 85 : 831 837, 2003
    • (2003) J Bone Joint Surg Am , vol.85 , pp. 831-837
    • Hutchinson, D.T.1    Horwitz, D.S.2    Ha, G.3
  • 10
    • 0030278265 scopus 로고    scopus 로고
    • Biomechanical analysis of tension band fixation for olecranon fracture treatment
    • Kozin SH Berglund LJ Cooney WP, et al : Biomechanical analysis of tension band fixation for olecranon fracture treatment. J Shoulder Elbow Surg 5 : 442 448, 1996
    • (1996) J Shoulder Elbow Surg , vol.5 , pp. 442-448
    • Kozin, S.H.1    Berglund, L.J.2    Cooney, W.P.3
  • 11
    • 1642406116 scopus 로고    scopus 로고
    • Biomechanical evaluation of intramedullary nail versus tension band fixation for transverse olecranon fractures
    • Molloy S Jasper LE Elliott DS, et al : Biomechanical evaluation of intramedullary nail versus tension band fixation for transverse olecranon fractures. J Orthop Trauma 18 : 170 174, 2004
    • (2004) J Orthop Trauma , vol.18 , pp. 170-174
    • Molloy, S.1    Jasper, L.E.2    Elliott, D.S.3
  • 12
    • 0034237449 scopus 로고    scopus 로고
    • K-wire position in tension band wiring of the olecranon - A comparison of two techniques
    • Mullett JH Shannon F Noel J, et al : K-wire position in tension band wiring of the olecranon - a comparison of two techniques. Injury 31 : 427 431, 2000
    • (2000) Injury , vol.31 , pp. 427-431
    • Mullett, J.H.1    Shannon, F.2    Noel, J.3
  • 13
    • 0023473070 scopus 로고
    • Displaced olecranon fractures in adults. Biomechanical analysis of fixation methods
    • Murphy DF Greene WB Gilbert JA, et al : Displaced olecranon fractures in adults. Biomechanical analysis of fixation methods. Clin Orthop 224 : 210 214, 1987
    • (1987) Clin Orthop , vol.224 , pp. 210-214
    • Murphy, D.F.1    Greene, W.B.2    Gilbert, J.A.3
  • 14
    • 0031024872 scopus 로고    scopus 로고
    • Biomechanical evaluation of tension band placement for the repair of olecranon fractures
    • Paremain GP Novak VP Jinnah RH, et al : Biomechanical evaluation of tension band placement for the repair of olecranon fractures. Clin Orthop 335 : 325 330, 1997
    • (1997) Clin Orthop , vol.335 , pp. 325-330
    • Paremain, G.P.1    Novak, V.P.2    Jinnah, R.H.3
  • 15
    • 0030454261 scopus 로고    scopus 로고
    • Fixation stability of olecranon osteotomies
    • Petraco DM Koval KJ Kummer FJ, et al : Fixation stability of olecranon osteotomies. Clin Orthop 333 : 181 185, 1996
    • (1996) Clin Orthop , vol.333 , pp. 181-185
    • Petraco, D.M.1    Koval, K.J.2    Kummer, F.J.3
  • 16
    • 0031267131 scopus 로고    scopus 로고
    • Biomechanical comparison of fixation methods in transverse olecranon fractures: A cadaveric study
    • Prayson MJ Williams JL Marshall MP, et al : Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study. J Orthop Trauma 11 : 565 572, 1997
    • (1997) J Orthop Trauma , vol.11 , pp. 565-572
    • Prayson, M.J.1    Williams, J.L.2    Marshall, M.P.3
  • 17
    • 0038715575 scopus 로고    scopus 로고
    • Posterior olecranon plating: Biomechanical and clinical evaluation of a new operative technique
    • Tejwani NC Garnham IR Wolinsky PR, et al : Posterior olecranon plating: biomechanical and clinical evaluation of a new operative technique. Bull Hosp Joint Dis 61 : 27 31, 2002 2003
    • (2002) Bull Hosp Joint Dis , vol.61 , pp. 27-31
    • Tejwani, N.C.1    Garnham, I.R.2    Wolinsky, P.R.3
  • 18
    • 0033945691 scopus 로고    scopus 로고
    • Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture
    • Wu CC Tai CL Shih CH : Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture. J Trauma 48 : 1063 7, 2000
    • (2000) J Trauma , vol.48 , pp. 1063-7
    • Wu, C.C.1    Tai, C.L.2    Shih, C.H.3
  • 19
    • 0041384085 scopus 로고    scopus 로고
    • Biomechanical comparison of a circular external skeletal fixator construct to pin and tension band wire fixation for the stabilization of olecranon osteotomies in dogs: A cadaveric study
    • Halling KB Lewis DD Cross AR, et al : Biomechanical comparison of a circular external skeletal fixator construct to pin and tension band wire fixation for the stabilization of olecranon osteotomies in dogs: a cadaveric study. Vet Surg 32 : 324 335, 2003
    • (2003) Vet Surg , vol.32 , pp. 324-335
    • Halling, K.B.1    Lewis, D.D.2    Cross, A.R.3
  • 20
    • 0026572229 scopus 로고
    • Tension band wiring of olecranon fractures. a modification of the AO technique
    • Rowland SA Burkhart SS : Tension band wiring of olecranon fractures. A modification of the AO technique. Clin Orthop 277 : 238 242, 1992
    • (1992) Clin Orthop , vol.277 , pp. 238-242
    • Rowland, S.A.1    Burkhart, S.S.2
  • 21
    • 0027988796 scopus 로고
    • Tension band wiring of olecranon fractures: A modification of the AO technique
    • Roe SC : Tension band wiring of olecranon fractures: a modification of the AO technique. Clin Orthop 308 : 284 28, 1994
    • (1994) Clin Orthop , vol.308 , pp. 284-28
    • Roe, S.C.1
  • 22
    • 34250403766 scopus 로고
    • Theory of traction. Determination of the optimal arrangement of metal in the dorsal traction of an olecranon fracture
    • Labitzke R : Theory of traction. Determination of the optimal arrangement of metal in the dorsal traction of an olecranon fracture. Arch Orthop Unfallchir 81 : 179 192, 1975
    • (1975) Arch Orthop Unfallchir , vol.81 , pp. 179-192
    • Labitzke, R.1
  • 23
    • 0018958967 scopus 로고
    • Technic and results of lateral tension-band wiring of patella and olecranon-fractures
    • Labitzke R Towfigh H : Technic and results of lateral tension-band wiring of patella and olecranon-fractures. Unfallheilkunde 83 : 450 456, 1980
    • (1980) Unfallheilkunde , vol.83 , pp. 450-456
    • Labitzke, R.1    Towfigh, H.2
  • 25
    • 0028985722 scopus 로고
    • Traditional versus alternative olecranon osteotomy. Historical review and biomechanical analysis of several techniques
    • Voor MJ Sugita S Seligson D : Traditional versus alternative olecranon osteotomy. Historical review and biomechanical analysis of several techniques. Am J Orthop Feb Suppl 24 : 17 26, 1995
    • (1995) Am J Orthop Feb Suppl , vol.24 , pp. 17-26
    • Voor, M.J.1    Sugita, S.2    Seligson, D.3
  • 26
    • 1542512293 scopus 로고    scopus 로고
    • A mechanical comparison of veterinary linear external fixation systems
    • White DT Bronson DG Welch RD : A mechanical comparison of veterinary linear external fixation systems. Vet Surg 32 : 507 514, 2003
    • (2003) Vet Surg , vol.32 , pp. 507-514
    • White, D.T.1    Bronson, D.G.2    Welch, R.D.3
  • 27
    • 0036654099 scopus 로고    scopus 로고
    • Are circular external fixators weakened by the use of hemispheric washers?
    • Marcellin-Little DJ Roe SC Rovesti GL, et al : Are circular external fixators weakened by the use of hemispheric washers? Vet Surg 31 : 367 374, 2002
    • (2002) Vet Surg , vol.31 , pp. 367-374
    • Marcellin-Little, D.J.1    Roe, S.C.2    Rovesti, G.L.3
  • 28
    • 33744494341 scopus 로고    scopus 로고
    • McMaster-Carr Supply Catalog. Document 8573KAC. [Catalog Web site]. Available at:
    • McMaster-Carr Supply Catalog. Document 8573KAC. [Catalog Web site]. Available at :
  • 29
    • 33744491587 scopus 로고    scopus 로고
    • Tribiological behavior of titanium sliding against bone
    • Mischler S Pax G : Tribiological behavior of titanium sliding against bone. Eur Cells Mat 3 (Suppl) : 28 29, 2002
    • (2002) Eur Cells Mat , vol.3 , pp. 28-29
    • Mischler, S.1    Pax, G.2
  • 30
    • 0033878656 scopus 로고    scopus 로고
    • Functional outcome after open supracondylar fractures of the humerus. the effect of the surgical approach
    • McKee MD Kim J Kebaish K, et al : Functional outcome after open supracondylar fractures of the humerus. The effect of the surgical approach. J Bone Joint Surg Br 82 : 646 651, 2000
    • (2000) J Bone Joint Surg Br , vol.82 , pp. 646-651
    • McKee, M.D.1    Kim, J.2    Kebaish, K.3
  • 31
    • 0036854433 scopus 로고    scopus 로고
    • Evolution of the internal fixation of long bone fractures. the scientific basis of biological internal fixation: Choosing a new balance between stability and biology
    • Perren SM : Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84 : 1093 1110, 2002
    • (2002) J Bone Joint Surg Br , vol.84 , pp. 1093-1110
    • Perren, S.M.1
  • 32
    • 0031182037 scopus 로고    scopus 로고
    • Mechanical characteristics and comparisons of cerclage wires: Introduction of the double-wrap and loop/twist tying methods
    • Roe SC : Mechanical characteristics and comparisons of cerclage wires: introduction of the double-wrap and loop/twist tying methods. Vet Surg 26 : 310 316, 1997
    • (1997) Vet Surg , vol.26 , pp. 310-316
    • Roe, S.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.