메뉴 건너뛰기




Volumn 15, Issue 1, 2006, Pages 24-34

Attachment systems for implant retained overdentures: A literature review

Author keywords

Ball attachments; Bars; Clips; Implant retained overdentures; Magnets

Indexed keywords

DENTURE; HUMAN; MECHANICAL STRESS; OSTEOLYSIS; PATIENT SATISFACTION; PERIODONTAL DISEASE; REVIEW; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TREATMENT OUTCOME;

EID: 33646847004     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.id.0000202419.21665.36     Document Type: Review
Times cited : (218)

References (73)
  • 1
    • 0036654483 scopus 로고    scopus 로고
    • The McGill consensus statement on overdentures. Mandibular two-implant overdentures as the first choice standard of care for edentulous patients
    • Feine JS, Carlsson GE, Awad MA, et al. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as the first choice standard of care for edentulous patients. Gerodontology. 2002;19:3-4.
    • (2002) Gerodontology , vol.19 , pp. 3-4
    • Feine, J.S.1    Carlsson, G.E.2    Awad, M.A.3
  • 2
    • 0141608943 scopus 로고    scopus 로고
    • Annual review of selected dental literature: Report of the committee on scientific investigation of the American Academy of Restorative Dentistry
    • Allen EP, Bayne SC, Brodine AH, et al. Annual review of selected dental literature: Report of the committee on scientific investigation of the American Academy of Restorative Dentistry. J Prosthet Dent. 2003;90:50-80.
    • (2003) J Prosthet Dent. , vol.90 , pp. 50-80
    • Allen, E.P.1    Bayne, S.C.2    Brodine, A.H.3
  • 3
    • 0024031111 scopus 로고
    • A retrospective multicenter evaluation of osseointegrated implants supporting overdentures
    • Engquist B, Bergendal T, Kallus T, et al. A retrospective multicenter evaluation of osseointegrated implants supporting overdentures. Int J Oral Maxillofac Implants. 1988:3:129-134.
    • (1988) Int J Oral Maxillofac Implants , vol.3 , pp. 129-134
    • Engquist, B.1    Bergendal, T.2    Kallus, T.3
  • 4
    • 0031992011 scopus 로고    scopus 로고
    • Rigidly splinted implants in the resorbed maxilla to retain a hinging overdenture: A series of clinical reports for up to 4 years
    • Naert I, Gizani S, van Steenberghe D. Rigidly splinted implants in the resorbed maxilla to retain a hinging overdenture: A series of clinical reports for up to 4 years. J Prosthet Dent. 1998:79:156-164.
    • (1998) J Prosthet Dent , vol.79 , pp. 156-164
    • Naert, I.1    Gizani, S.2    Van Steenberghe, D.3
  • 5
    • 0032017010 scopus 로고    scopus 로고
    • Implant-supported overdentures: A longitudinal prospective study
    • Bergendahl T, Engquist B. Implant-supported overdentures: A longitudinal prospective study. Int J Oral Maxillofac Implants. 1998:13:253-262.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 253-262
    • Bergendahl, T.1    Engquist, B.2
  • 6
    • 0034157335 scopus 로고    scopus 로고
    • Implant-supported mandibular overdentures retained with ball or bar attachments: A randomized prospective 5-year study
    • Gotfredsen K, Holm B. Implant-supported mandibular overdentures retained with ball or bar attachments: A randomized prospective 5-year study. Int J Prosthodont. 2000;13:125-130.
    • (2000) Int J Prosthodont , vol.13 , pp. 125-130
    • Gotfredsen, K.1    Holm, B.2
  • 7
    • 0029448731 scopus 로고
    • The incomprehensible success of the implant stabilized overdenture in the edentulous mandible: A literature review on transfer of chewing forces to bone surrounding implants
    • Chao YL, Meijer HJA, Van dort RP, et al. The incomprehensible success of the implant stabilized overdenture in the edentulous mandible: A literature review on transfer of chewing forces to bone surrounding implants. Eur J Prosthodont Restor Dent. 1995;3:255-261.
    • (1995) Eur J Prosthodont Restor Dent , vol.3 , pp. 255-261
    • Chao, Y.L.1    Meijer, H.J.A.2    Van Dort, R.P.3
  • 8
    • 0026161040 scopus 로고
    • Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report
    • Naert I, Quirynen M, Theuniers G, et al. Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report. J Prosthet Dent. 1991;65:671-680.
    • (1991) J Prosthet Dent , vol.65 , pp. 671-680
    • Naert, I.1    Quirynen, M.2    Theuniers, G.3
  • 9
    • 0028395085 scopus 로고
    • Implant-supported maxillary overdentures: Outcome in planned and emergency cases
    • Palmqvist S, Sondell K, Swartz B. Implant-supported maxillary overdentures: Outcome in planned and emergency cases. Int J Oral Maxillofac Implants. 1994; 9:184-190.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 184-190
    • Palmqvist, S.1    Sondell, K.2    Swartz, B.3
  • 10
    • 0347770679 scopus 로고    scopus 로고
    • Maxillary overdentures retained by splinted and unsplinted implants: A retrospective study
    • Närhi TO, Hevinga M, Voorsmit RACA, et al. Maxillary overdentures retained by splinted and unsplinted implants: A retrospective study. Int J Oral Maxillofac Implants. 2001;16:259-266.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 259-266
    • Närhi, T.O.1    Hevinga, M.2    Raca, V.3
  • 11
    • 0035259072 scopus 로고    scopus 로고
    • Implant-supported overdentures, a prevention of bone loss in edentulous mandibles? A 5-year follow-up study
    • Von Wowern N, Gotfredsen K. Implant-supported overdentures, a prevention of bone loss in edentulous mandibles? A 5-year follow-up study. Clin Oral Implants Res. 2001;12:19-25.
    • (2001) Clin Oral Implants Res. , vol.12 , pp. 19-25
    • Von Wowern, N.1    Gotfredsen, K.2
  • 12
    • 0033177408 scopus 로고    scopus 로고
    • Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI dental implant system
    • Wismeijer D, van Waas MA, Mulder J, et al. Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI dental implant system. Clin Oral Implants Res. 1999;10:297-306.
    • (1999) Clin Oral Implants Res. , vol.10 , pp. 297-306
    • Wismeijer, D.1    Van Waas, M.A.2    Mulder, J.3
  • 13
    • 0032083031 scopus 로고    scopus 로고
    • A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: Peri-implant outcome
    • Naert I, Gizani S, Vuylsteke M, et al. A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: Peri-implant outcome. Clin Oral Implants Res. 1998;9:170-177.
    • (1998) Clin Oral Implants Res. , vol.9 , pp. 170-177
    • Naert, I.1    Gizani, S.2    Vuylsteke, M.3
  • 14
    • 0033122044 scopus 로고    scopus 로고
    • Mandibular overdentures stabilized by Astra Tech implants with either Ball attachments or Magnets: 5 year results
    • Davis DM, Packer ME. Mandibular overdentures stabilized by Astra Tech implants with either Ball attachments or Magnets: 5 year results. Int J Prosthodont. 1999;12:222-229.
    • (1999) Int J Prosthodont , vol.12 , pp. 222-229
    • Davis, D.M.1    Packer, M.E.2
  • 15
    • 0036738803 scopus 로고    scopus 로고
    • Comparison of 2 retentive systems for implant-supported overdentures: Soft tissue management and evaluation of patient satisfaction
    • Karabuda C, Tosun T, Ermis E, et al. Comparison of 2 retentive systems for implant-supported overdentures: Soft tissue management and evaluation of patient satisfaction. J Periodontol. 2002;73:1067-1070.
    • (2002) J Periodontol. , vol.73 , pp. 1067-1070
    • Karabuda, C.1    Tosun, T.2    Ermis, E.3
  • 16
    • 0025657625 scopus 로고
    • Clinical evaluation of overdenture restorations supported by osseointegrated titanium implants: A retrospective study
    • Mericske-Stern R. Clinical evaluation of overdenture restorations supported by osseointegrated titanium implants: A retrospective study. J Oral Maxillofac Implants. 1990;5:375-383.
    • (1990) J Oral Maxillofac Implants , vol.5 , pp. 375-383
    • Mericske-Stern, R.1
  • 17
    • 0345898780 scopus 로고
    • A comparative evaluation of some outcome measures of implant systems and suprastructures types in mandibular implant overdenture treatment
    • Cune MS, de Putter C. A comparative evaluation of some outcome measures of implant systems and suprastructures types in mandibular implant overdenture treatment. J Oral Maxillofac Implants. 1994; 9:548-555
    • (1994) J Oral Maxillofac Implants , vol.9 , pp. 548-555
    • Cune, M.S.1    De Putter, C.2
  • 18
    • 0029175466 scopus 로고
    • The effects of prefabricated bar design on the success of overdentures stabilized by implants
    • Wright PS, Watson RM, Heath MR. The effects of prefabricated bar design on the success of overdentures stabilized by implants. J Oral Maxillofac Implants. 1995; 10:79-87.
    • (1995) J Oral Maxillofac Implants
    • Wright, P.S.1    Watson, R.M.2    Heath, M.R.3
  • 19
    • 0032109199 scopus 로고    scopus 로고
    • Treatment concept for mandibular overdentures supported by endosseous implants: A literature review
    • Batenburg RHK, Meijer HJA, Raghoebar GM, et al. Treatment concept for mandibular overdentures supported by endosseous implants: A literature review. J Oral Maxillofac Implants. 1998; 13:539-545.
    • (1998) J Oral Maxillofac Implants , vol.13 , pp. 539-545
    • Batenburg, R.H.K.1    Meijer, H.J.A.2    Raghoebar, G.M.3
  • 20
    • 0035315834 scopus 로고    scopus 로고
    • Inter-abutment and peri-abutment mucosal enlargement with mandibular implant overdentures
    • Payne GT, Solomons YF, Tawse-Smith A, et al. Inter-abutment and peri-abutment mucosal enlargement with mandibular implant overdentures. Clin Oral Implants Res. 2001;12:179-187.
    • (2001) Clin Oral Implants Res. , vol.12 , pp. 179-187
    • Payne, G.T.1    Solomons, Y.F.2    Tawse-Smith, A.3
  • 21
    • 0035656476 scopus 로고    scopus 로고
    • Retention of maxillary implant overdenture bars of different designs
    • Williams BH, Ochiai KT, Hojo S, et al. Retention of maxillary implant overdenture bars of different designs. J Prosthet Dent. 2001;86:603-607.
    • (2001) J Prosthet Dent , vol.86 , pp. 603-607
    • Williams, B.H.1    Ochiai, K.T.2    Hojo, S.3
  • 22
    • 0031088933 scopus 로고    scopus 로고
    • Retention of ERA direct overdenture attachments before and after fatigue loading
    • Gamborena JI, Hazelton LR, Nabadalung D, et al. Retention of ERA direct overdenture attachments before and after fatigue loading. Int J Prosthodont. 1997;10:123-130.
    • (1997) Int J Prosthodont , vol.10 , pp. 123-130
    • Gamborena, J.I.1    Hazelton, L.R.2    Nabadalung, D.3
  • 23
    • 0029642214 scopus 로고
    • Prosthetic management of the atrophic mandible using endosseous implants and overdentures: A six year review
    • Chan MFWY, Johnston C, Howell RA, et al. Prosthetic management of the atrophic mandible using endosseous implants and overdentures: A six year review. Br Dent J. 1995;179:329-337.
    • (1995) Br Dent J. , vol.179 , pp. 329-337
    • Mfwy, C.1    Johnston, C.2    Howell, R.A.3
  • 24
    • 0028434828 scopus 로고
    • A comparative prospective study of splinted and unsplinted Brånemark implants in mandibular overdenture therapy. A preliminary report
    • Naert I, Quirynen M, Hooghe M, et al. A comparative prospective study of splinted and unsplinted Brånemark implants in mandibular overdenture therapy. A preliminary report. J Prosthet Dent. 1994;71:486-492.
    • (1994) J Prosthet Dent , vol.71 , pp. 486-492
    • Naert, I.1    Quirynen, M.2    Hooghe, M.3
  • 25
    • 0031086172 scopus 로고    scopus 로고
    • Comparison of retention and release periods for implant overdenture attachments
    • Petropoulos VC, Smith W, Kousvelari E. Comparison of retention and release periods for implant overdenture attachments. J Oral Maxillofac Implants. 1997;12:176-185.
    • (1997) J Oral Maxillofac Implants , vol.12 , pp. 176-185
    • Petropoulos, V.C.1    Smith, W.2    Kousvelari, E.3
  • 27
    • 0036835004 scopus 로고    scopus 로고
    • Magnetic retention in prosthetic dentistry
    • Walmsley AD. Magnetic retention in prosthetic dentistry. Dent Update. 2002; 29:428-433.
    • (2002) Dent Update , vol.29 , pp. 428-433
    • Walmsley, A.D.1
  • 28
    • 0030144187 scopus 로고    scopus 로고
    • The effect of simulated function on the retention of bar-clip retained removable prostheses
    • Breeding LC, Dixon DL, Schmitt S. The effect of simulated function on the retention of bar-clip retained removable prostheses. J Prosthet Dent. 1996;75: 570-573.
    • (1996) J Prosthet Dent , vol.75 , pp. 570-573
    • Breeding, L.C.1    Dixon, D.L.2    Schmitt, S.3
  • 29
    • 0032198815 scopus 로고    scopus 로고
    • Photoelastic stress patterns produced by implant -Retained overdentures
    • Kenney R, Richards MW. Photoelastic stress patterns produced by implant -Retained overdentures. J Prosthet Dent. 1998;80:559-564.
    • (1998) J Prosthet Dent , vol.80 , pp. 559-564
    • Kenney, R.1    Richards, M.W.2
  • 30
    • 0038488565 scopus 로고    scopus 로고
    • In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: Comparison of load transfer and denture stability
    • Tokuhisa M, Matsushita Y, Koyano K. In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: Comparison of load transfer and denture stability. Int J Prosthodont. 2003;16:128-134.
    • (2003) Int J Prosthodont , vol.16 , pp. 128-134
    • Tokuhisa, M.1    Matsushita, Y.2    Koyano, K.3
  • 31
    • 0030337833 scopus 로고    scopus 로고
    • Effects of overdenture retention designs and implant orientations on load transfer characteristics
    • Federick DR, Caputo AA. Effects of overdenture retention designs and implant orientations on load transfer characteristics. J Prosthet Dent. 1996;76:624-632.
    • (1996) J Prosthet Dent , vol.76 , pp. 624-632
    • Federick, D.R.1    Caputo, A.A.2
  • 32
    • 0032060144 scopus 로고    scopus 로고
    • Mandibular implant-retained overdenture: Finite element analysis of two anchorage systems
    • Menicucci G, Lorenzetti M, Pera P, et al. Mandibular implant-retained overdenture: Finite element analysis of two anchorage systems. J Oral Maxillofac Implants. 1998;13:369376.
    • (1998) J Oral Maxillofac Implants , vol.13 , pp. 369376
    • Menicucci, G.1    Lorenzetti, M.2    Pera, P.3
  • 33
    • 0027620595 scopus 로고
    • A three dimensional finite- Element analysis of bone around dental implants in an edentulous human mandible
    • Meijer HJA, Starmans FJM, Steen WHA, et al. A three dimensional finite- element analysis of bone around dental implants in an edentulous human mandible. Arch Oral Biol. 1993;38:491-496.
    • (1993) Arch Oral Biol. , vol.38 , pp. 491-496
    • Meijer, H.J.A.1    Starmans, F.J.M.2    Steen, W.H.A.3
  • 34
    • 0028433413 scopus 로고
    • A three dimensional finite- Element study on two versus four implants in an edentulous mandible
    • Meijer HJA, Starmans FJM, Steen WHA, et al. A three dimensional finite- element study on two versus four implants in an edentulous mandible. Int J Prosthodont. 1994;7:271-279.
    • (1994) Int J Prosthodont , vol.7 , pp. 271-279
    • Meijer, H.J.A.1    Starmans, F.J.M.2    Steen, W.H.A.3
  • 35
    • 0026892027 scopus 로고
    • Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible
    • Meijer HJA, Kuiper JH, Starmans FJM, et al. Stress distribution around dental implants: Influence of superstructure, length of implants, and height of mandible. J Prosthet Dent. 1992;68:96-102.
    • (1992) J Prosthet Dent , vol.68 , pp. 96-102
    • Meijer, H.J.A.1    Kuiper, J.H.2    Starmans, F.J.M.3
  • 36
    • 0032201305 scopus 로고    scopus 로고
    • Mandibular implant-retained overdenture: A clinical trial of two anchorage systems
    • Menicucci G, Lorenzetti M, Fera P, et al. Mandibular implant-retained overdenture: A clinical trial of two anchorage systems. J Oral Maxillofac Implants. 1998;13:851-856.
    • (1998) J Oral Maxillofac Implants , vol.13 , pp. 851-856
    • Menicucci, G.1    Lorenzetti, M.2    Fera, P.3
  • 37
    • 0033290520 scopus 로고    scopus 로고
    • In vivo forces on oral implants supporting a mandibular overdenture: The influence of attachment system
    • Duyck J, Van Oosterwyck H, Van der Sloten J, et al. In vivo forces on oral implants supporting a mandibular overdenture: The influence of attachment system. Clin Oral Investig. 1999;3:201-207.
    • (1999) Clin Oral Investig. , vol.3 , pp. 201-207
    • Duyck, J.1    Van Oosterwyck, H.2    Van Der Sloten, J.3
  • 38
    • 0034277057 scopus 로고    scopus 로고
    • Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures
    • Sadowsky SJ, Caputo AA. Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures. J Prosthet Dent. 2000;84:327-334.
    • (2000) J Prosthet Dent , vol.84 , pp. 327-334
    • Sadowsky, S.J.1    Caputo, A.A.2
  • 39
    • 0026875574 scopus 로고
    • Implant and prosthetic treatment of the edentulous maxilla using a bar-supported prosthesis
    • Krämer A, Weber H, Benzing U. Implant and prosthetic treatment of the edentulous maxilla using a bar-supported prosthesis. Int J Oral Maxillofac Implants. 1992;7:251-255.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 251-255
    • Krämer, A.1    Weber, H.2    Benzing, U.3
  • 40
    • 0029263858 scopus 로고
    • Bio-mechanical aspects of 2 different implant-prosthetic concepts for the edentulous maxilla
    • Benzing UR, Gall H, Weber H. Bio-mechanical aspects of 2 different implant-prosthetic concepts for the edentulous maxilla. Int J Oral Maxillofac Implants. 1995;10:188-198.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 188-198
    • Benzing, U.R.1    Gall, H.2    Weber, H.3
  • 41
    • 0031086488 scopus 로고    scopus 로고
    • Effects of attachment clips on occlusal force transmission in removable implant-supported overdentures and cantilevered superstructures
    • Kayacan R, Ballarini R, Mullen RL, et al. Effects of attachment clips on occlusal force transmission in removable implant-supported overdentures and cantilevered superstructures. Int J Oral Maxillofac Implants. 1997;12:228-236.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 228-236
    • Kayacan, R.1    Ballarini, R.2    Mullen, R.L.3
  • 43
    • 0035653643 scopus 로고    scopus 로고
    • Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment
    • Heckmann SM, Winter W, Meyer M, et al. Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment. Clin Oral Implants Res. 2001;12:640-647.
    • (2001) Clin Oral Implants Res. , vol.12 , pp. 640-647
    • Heckmann, S.M.1    Winter, W.2    Meyer, M.3
  • 44
    • 0024673896 scopus 로고
    • Complete dentures fixed on dental implants: Chewing patterns and implant stress
    • Setz J, Krämer A, Benzing U, et al. Complete dentures fixed on dental implants: Chewing patterns and implant stress. J Oral Maxillofac Implants. 1989;4: 107-111.
    • (1989) J Oral Maxillofac Implants , vol.4 , pp. 107-111
    • Setz, J.1    Krämer, A.2    Benzing, U.3
  • 45
    • 0030320450 scopus 로고    scopus 로고
    • 3-D in vivo force measurements on mandibular implants supporting overdentures. A comparative study
    • Mericske-Stern R, Piotti M, Sirtes G. 3-D in vivo force measurements on mandibular implants supporting overdentures. A comparative study. Clin Oral Implants Res. 1996;7:387-396.
    • (1996) Clin Oral Implants Res. , vol.7 , pp. 387-396
    • Mericske-Stern, R.1    Piotti, M.2    Sirtes, G.3
  • 46
    • 0029684525 scopus 로고    scopus 로고
    • The edentulous predicament. I: A prospective study of the effectiveness of implant supported fixed prostheses
    • Zarb GA, Schmitt A. The edentulous predicament. I: A prospective study of the effectiveness of implant supported fixed prostheses. J Am Dent Assoc. 1996; 127:59-65.
    • (1996) J Am Dent Assoc. , vol.127 , pp. 59-65
    • Zarb, G.A.1    Schmitt, A.2
  • 47
    • 0033182162 scopus 로고    scopus 로고
    • Implant-supported removable overdentures in the edentulous maxilla: Clinical and technical aspects
    • Zitzmann NU, Marinello CP. Implant-supported removable overdentures in the edentulous maxilla: Clinical and technical aspects. Int J Prosthodont. 1999;12:385-390.
    • (1999) Int J Prosthodont , vol.12 , pp. 385-390
    • Zitzmann, N.U.1    Marinello, C.P.2
  • 48
    • 0027017737 scopus 로고
    • Finite element analysis (FEA) studies in 2.5-mm round bar design: The effects of bar length and material composition on bar failure
    • Bidez MW, McLoughlin SW, Chen Y, et al. Finite element analysis (FEA) studies in 2.5-mm round bar design: The effects of bar length and material composition on bar failure. J Oral Implantol. 1992;18:122-128.
    • (1992) J Oral Implantol , vol.18 , pp. 122-128
    • Bidez, M.W.1    McLoughlin, S.W.2    Chen, Y.3
  • 49
    • 0027619569 scopus 로고
    • Finite element analysis of two-abutment Hader bar designs
    • Bidez MW, McLoughlin SW, Chen Y, et al. Finite element analysis of two-abutment Hader bar designs. Implant Dent. 1993;2:107-114.
    • (1993) Implant Dent , vol.2 , pp. 107-114
    • Bidez, M.W.1    McLoughlin, S.W.2    Chen, Y.3
  • 50
    • 0027662462 scopus 로고
    • Finite element analysis of four-abutment Hader bar designs
    • Bidez MW, Chen Y, McLoughlin SW, et al. Finite element analysis of four-abutment Hader bar designs. Implant Dent. 1993;2:171-176.
    • (1993) Implant Dent , vol.2 , pp. 171-176
    • Bidez, M.W.1    Chen, Y.2    McLoughlin, S.W.3
  • 52
    • 0026873529 scopus 로고
    • Failures and complications in 92 consecutively inserted overdentures supported by Brånemark implants in severely resorbed edentulous maxillae: A study from prosthetic treatment to first annual check-up
    • Jemt T, Book K, Linden, et al. Failures and complications in 92 consecutively inserted overdentures supported by Brånemark implants in severely resorbed edentulous maxillae: A study from prosthetic treatment to first annual check-up. Int J Oral Maxillofac Implants. 1992;7:162167.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 162167
    • Jemt, T.1    Book, K.2    Linden3
  • 53
    • 0027026658 scopus 로고
    • A multicenter study of overdentures supported by Brånemark implants
    • Johns RB, Jemt T, Heath MR, et al. A multicenter study of overdentures supported by Brånemark implants. Int J Oral Maxillofac Implants. 1992;7:513-522.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 513-522
    • Johns, R.B.1    Jemt, T.2    Heath, M.R.3
  • 54
    • 0027569775 scopus 로고
    • A clinical and radiological two-year follow-up study of maxillary overdentures on osseointegrated implants
    • Smedberg JI, Lothigius E, Bodin I, et al. A clinical and radiological two-year follow-up study of maxillary overdentures on osseointegrated implants. Clin Oral Implants Res. 1993;4:39-46.
    • (1993) Clin Oral Implants Res. , vol.4 , pp. 39-46
    • Smedberg, J.I.1    Lothigius, E.2    Bodin, I.3
  • 55
    • 0028390422 scopus 로고
    • Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: A 5-year report
    • Hemmings KW, Scmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: A 5-year report. Int J Oral Maxillofac Implants. 1994; 9:191-196.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 191-196
    • Hemmings, K.W.1    Scmitt, A.2    Zarb, G.A.3
  • 56
    • 0029398677 scopus 로고
    • Overdentures supported by ITI implants: A 6.5-year evaluation of patient satisfaction and prosthetic after-care
    • Wismeyer D, van Waas MA, Vermeeren JI. Overdentures supported by ITI implants: A 6.5-year evaluation of patient satisfaction and prosthetic after-care. Int J Oral Maxillofac Implants. 1995;10:744749.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 744749
    • Wismeyer, D.1    Van Waas, M.A.2    Vermeeren, J.I.3
  • 57
    • 0031586908 scopus 로고    scopus 로고
    • Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital
    • Allen PF, McMillan AS, Smith DG. Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital. Br Dent J. 1997;182:298-302.
    • (1997) Br Dent J. , vol.182 , pp. 298-302
    • Allen, P.F.1    McMillan, A.S.2    Smith, D.G.3
  • 58
    • 0035296434 scopus 로고    scopus 로고
    • Effectiveness of maxillary overdentures supported by implants: Maintenance and prosthetic complications
    • Kiener P, Oetterli M, Mericske E, et al. Effectiveness of maxillary overdentures supported by implants: Maintenance and prosthetic complications. Int J Prosthodont. 2001;14:133-140.
    • (2001) Int J Prosthodont , vol.14 , pp. 133-140
    • Kiener, P.1    Oetterli, M.2    Mericske, E.3
  • 59
    • 0034188906 scopus 로고    scopus 로고
    • The prosthodontic maintenance requirements of mandibular mucosa- And implant-supported overdentures: A review of the literature
    • Payne AGT, Solomons YF. The prosthodontic maintenance requirements of mandibular mucosa- and implant-supported overdentures: A review of the literature. Int J Prosthodont. 2000;13:238-245.
    • (2000) Int J Prosthodont , vol.13 , pp. 238-245
    • Payne, A.G.T.1    Solomons, Y.F.2
  • 60
    • 0035239842 scopus 로고    scopus 로고
    • The outcome of implant overdentures from a prosthodontic perspective: Pro posai for a classification protocol
    • Payne AGT, Walton TR, Walton JN, et al. The outcome of implant overdentures from a prosthodontic perspective: Pro posai for a classification protocol. Int J Prosthodont. 2001;14:27-32.
    • (2001) Int J Prosthodont , vol.14 , pp. 27-32
    • Payne, A.G.T.1    Walton, T.R.2    Walton, J.N.3
  • 62
    • 0031174733 scopus 로고    scopus 로고
    • Prosthodontic treatment, patient response, and the need for maintenance of complete implant-supported overdentures: An appraisal of five years of prospective study
    • Watson RM, Jemt T, Chai J, et al. Prosthodontic treatment, patient response, and the need for maintenance of complete implant-supported overdentures: An appraisal of five years of prospective study. Int J Prosthodont. 1997;10:345-354.
    • (1997) Int J Prosthodont , vol.10 , pp. 345-354
    • Watson, R.M.1    Jemt, T.2    Chai, J.3
  • 63
    • 0028395574 scopus 로고
    • Problems with prostheses on implants: A retrospective study
    • Walton JN, MacEntee MI. Problems with prostheses on implants: A retrospective study. J Prosthet Dent. 1994;71: 283-288.
    • (1994) J Prosthet Dent , vol.71 , pp. 283-288
    • Walton, J.N.1    MacEntee, M.I.2
  • 64
    • 0035502560 scopus 로고    scopus 로고
    • Implant angulation: A measurement technique, implant overdenture maintenance, and the influence of surgical experience
    • Walton JN, Huizinga SC, Peck CC. Implant angulation: A measurement technique, implant overdenture maintenance, and the influence of surgical experience. Int J Prosthodont. 2001;14:523-530.
    • (2001) Int J Prosthodont , vol.14 , pp. 523-530
    • Walton, J.N.1    Huizinga, S.C.2    Peck, C.C.3
  • 65
    • 0030277223 scopus 로고    scopus 로고
    • The extent of maintenance required by implant-retained mandibular overdentures: A 3-year report
    • Davis DM, Rogers JO, Packer ME. The extent of maintenance required by implant-retained mandibular overdentures: A 3-year report. Int J Oral Maxillofac Implants. 1996;11:767-774.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 767-774
    • Davis, D.M.1    Rogers, J.O.2    Packer, M.E.3
  • 66
    • 0034189421 scopus 로고    scopus 로고
    • Mandibular implant-supported overdentures: A prospective evaluation of the burden of prosthodontic maintenance with 3 different attachment systems
    • Payne AGT, Solomons YF. Mandibular implant-supported overdentures: A prospective evaluation of the burden of prosthodontic maintenance with 3 different attachment systems. Int J Prosthodont 2000;13:246-253.
    • (2000) Int J Prosthodont , vol.13 , pp. 246-253
    • Payne, A.G.T.1    Solomons, Y.F.2
  • 67
    • 0141682755 scopus 로고    scopus 로고
    • A randomized clinical trial comparing two mandibular implant overdenture designs: 3-year prosthetic outcomes using a sic field protocol
    • Walton JN. A randomized clinical trial comparing two mandibular implant overdenture designs: 3-year prosthetic outcomes using a sic field protocol. Int J Prosthodont. 2003;16:255-260.
    • (2003) Int J Prosthodont , vol.16 , pp. 255-260
    • Walton, J.N.1
  • 68
    • 0031203252 scopus 로고    scopus 로고
    • Patient satisfaction with implant-supported mandibular overdentures. A comparison of three treatment strategies with ITI-dental implants
    • Wismeijer HJ, van Waas MA, Vermeeren JI, et al. Patient satisfaction with implant-supported mandibular overdentures. A comparison of three treatment strategies with ITI-dental implants. J Oral Maxillofac Surg. 1997;26:263-267.
    • (1997) J Oral Maxillofac Surg. , vol.26 , pp. 263-267
    • Wismeijer, H.J.1    Van Waas, M.A.2    Vermeeren, J.I.3
  • 69
    • 0026825778 scopus 로고
    • Patient satisfaction with overdentures supported by one-stage TPS implants
    • Wismeijer D, Vermeeren JIJH, van Waas MAJ. Patient satisfaction with overdentures supported by one-stage TPS implants. Int J Oral Maxillofac Implants. 1992; 7:51-55.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 51-55
    • Wismeijer, D.1    Jijh, V.2    Van Waas, M.A.J.3
  • 70
    • 0036725066 scopus 로고    scopus 로고
    • Cleansability of and patients' satisfaction with implant-retained overdentures: A retrospective comparison of two attachment methods
    • Ambard AJ, Fanchiang JC, Mueningghoff L, et al. Cleansability of and patients' satisfaction with implant-retained overdentures: A retrospective comparison of two attachment methods. J Am Dent Assoc. 2002;133:1237-1242.
    • (2002) J Am Dent Assoc. , vol.133 , pp. 1237-1242
    • Ambard, A.J.1    Fanchiang, J.C.2    Mueningghoff, L.3
  • 71
    • 0347705690 scopus 로고    scopus 로고
    • Implant supported overdentures-the copenhagen experience
    • Gotfredsen K. Implant supported overdentures-The Copenhagen experience. J Dent. 1997;25(suppl 1):S39-42.
    • (1997) J Dent , vol.25 , Issue.1 SUPPL.
    • Gotfredsen, K.1
  • 72
    • 0031264347 scopus 로고    scopus 로고
    • A longitudinal clinical assessment of spark erosion technology in implant-retained overdentures prostheses: A preliminary report
    • Toljanic JA, Antoniou D, Clark RS, et al. A longitudinal clinical assessment of spark erosion technology in implant-retained overdentures prostheses: A preliminary report. J Prosthet Dent. 1997;78: 490-495.
    • (1997) J Prosthet Dent , vol.78 , pp. 490-495
    • Toljanic, J.A.1    Antoniou, D.2    Clark, R.S.3
  • 73
    • 0029283713 scopus 로고
    • Prospective clinical evaluation of mandibular implant overdentures: Part II-patient satisfaction and preference
    • Burns DR, Unger JW, Elswick RK Jr, et al. Prospective clinical evaluation of mandibular implant overdentures: Part II-patient satisfaction and preference. J Prosthet Dent. 1995;73:364-369.
    • (1995) J Prosthet Dent , vol.73 , pp. 364-369
    • Burns, D.R.1    Unger, J.W.2    Elswick Jr., R.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.