메뉴 건너뛰기




Volumn 16, Issue 2, 2006, Pages 249-257

3.0 T versus 1.5 T: Coil Design Similarities and Differences

Author keywords

[No Author keywords available]

Indexed keywords

DEVICE; EQUIPMENT DESIGN; HUMAN; IMAGING SYSTEM; INTERMETHOD COMPARISON; NUCLEAR MAGNETIC RESONANCE IMAGING; OPTICAL RESOLUTION; PRIORITY JOURNAL; RADIOFREQUENCY; REVIEW; SIGNAL NOISE RATIO;

EID: 33646826501     PISSN: 10525149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nic.2006.03.001     Document Type: Review
Times cited : (2)

References (15)
  • 1
    • 0000132799 scopus 로고
    • Sensitivity of the zeugmatographic experiment involving human samples
    • Hoult D.I., and Richards R.E. Sensitivity of the zeugmatographic experiment involving human samples. J Magn Reson 34 (1979) 425-433
    • (1979) J Magn Reson , vol.34 , pp. 425-433
    • Hoult, D.I.1    Richards, R.E.2
  • 4
    • 0020585061 scopus 로고
    • Initial experience with nuclear magnetic resonance (NMR) imaging of the human breast
    • El Yousef S.J., Alfidi R.J., Duchesneau R.H., et al. Initial experience with nuclear magnetic resonance (NMR) imaging of the human breast. J Comput Assist Tomogr 7 2 (1983) 215-218
    • (1983) J Comput Assist Tomogr , vol.7 , Issue.2 , pp. 215-218
    • El Yousef, S.J.1    Alfidi, R.J.2    Duchesneau, R.H.3
  • 5
    • 0001770583 scopus 로고
    • NMR T-1 measurements in inhomogenous B1 with surface coils
    • Evelhoch J.L., and Ackerman J.J.H. NMR T-1 measurements in inhomogenous B1 with surface coils. J Magn Reson 53 (1983) 52-64
    • (1983) J Magn Reson , vol.53 , pp. 52-64
    • Evelhoch, J.L.1    Ackerman, J.J.H.2
  • 6
    • 0021280733 scopus 로고
    • Surface coil magnetic resonance imaging
    • Axel L. Surface coil magnetic resonance imaging. J Comput Assist Tomogr 8 (1984) 381-384
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 381-384
    • Axel, L.1
  • 8
    • 33646846756 scopus 로고    scopus 로고
    • Chen C.N., Hoult D.I. Signal and noise. In: Biomedical magnetic resonance technology. New York: Adam Hilger; 1989 p. 118
  • 9
    • 0024585573 scopus 로고
    • Increased RF power absorption in MR imaging due to RF coupling between body coil and surface coil
    • Buchli R., Saner M., Meier D., et al. Increased RF power absorption in MR imaging due to RF coupling between body coil and surface coil. Magn Reson Med 9 1 (1989) 105-112
    • (1989) Magn Reson Med , vol.9 , Issue.1 , pp. 105-112
    • Buchli, R.1    Saner, M.2    Meier, D.3
  • 11
    • 0842343509 scopus 로고    scopus 로고
    • 3 Tesla MRI: successful results with higher field strengths
    • Schmitt F., Grosu D., Mohr C., et al. 3 Tesla MRI: successful results with higher field strengths. Radiologe 44 1 (2004) 31-48
    • (2004) Radiologe , vol.44 , Issue.1 , pp. 31-48
    • Schmitt, F.1    Grosu, D.2    Mohr, C.3
  • 12
    • 2942703757 scopus 로고    scopus 로고
    • Observation of significant signal voids in images of large biological samples at 11.1 T
    • Beck B.L., Jenkins K., and Caserta J. Observation of significant signal voids in images of large biological samples at 11.1 T. Magn Reson Med 51 6 (2004) 1103-1107
    • (2004) Magn Reson Med , vol.51 , Issue.6 , pp. 1103-1107
    • Beck, B.L.1    Jenkins, K.2    Caserta, J.3
  • 13
    • 21844457678 scopus 로고    scopus 로고
    • Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations
    • Ibrahim T.S., Kangarlu A., and Chakeress D.W. Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations. IEEE Trans Biomed Eng 52 7 (2005) 1278-1284
    • (2005) IEEE Trans Biomed Eng , vol.52 , Issue.7 , pp. 1278-1284
    • Ibrahim, T.S.1    Kangarlu, A.2    Chakeress, D.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.