메뉴 건너뛰기




Volumn 53, Issue 4-5, 2006, Pages 403-410

A micromachined electrochemical sensor for free chlorine monitoring in drinking water

Author keywords

Chlorination; Drinking water; Electrochemical sensor; Microsensor

Indexed keywords

CHLORINATION; CHLORINE; MICROSENSORS; POTABLE WATER; PURIFICATION;

EID: 33646722836     PISSN: 02731223     EISSN: None     Source Type: Book Series    
DOI: 10.2166/wst.2006.146     Document Type: Article
Times cited : (15)

References (11)
  • 2
    • 0031084447 scopus 로고    scopus 로고
    • Smart-sensor approach for a fiber-optic-based residual chlorine monitor
    • Belz, M., Boyle, W.J.O., Klein, K-F. and Grattan, K.T.V. (1997). Smart-sensor approach for a fiber-optic-based residual chlorine monitor. Sensor Actuators B, 38-39, 380-385.
    • (1997) Sensor Actuators B , vol.38-39 , pp. 380-385
    • Belz, M.1    Boyle, W.J.O.2    Klein, K.-F.3    Grattan, K.T.V.4
  • 4
    • 0036644776 scopus 로고    scopus 로고
    • Development of micro-planar Ag/AgCl quasi-reference electrode with long term stability for an amperometric glucose sensor
    • Matsumoto, T., Ohashi, A. and Ito, N. (2002). Development of micro-planar Ag/AgCl quasi-reference electrode with long term stability for an amperometric glucose sensor. Anal. Chim. Acta., 462, 253-259.
    • (2002) Anal. Chim. Acta. , vol.462 , pp. 253-259
    • Matsumoto, T.1    Ohashi, A.2    Ito, N.3
  • 5
    • 0034793898 scopus 로고    scopus 로고
    • Simple miniaturized amperometric flow cell for monitoring residual chlorine in tap water
    • Okumura, A., Hirabayashi, A., Sasaki, Y. and Miyake, R. (2001). Simple miniaturized amperometric flow cell for monitoring residual chlorine in tap water. Anal. Sci., 17, 1113-1115.
    • (2001) Anal. Sci. , vol.17 , pp. 1113-1115
    • Okumura, A.1    Hirabayashi, A.2    Sasaki, Y.3    Miyake, R.4
  • 6
    • 33646732740 scopus 로고    scopus 로고
    • Water and wastewater industry application data sheet, PN 4950-10
    • Rosemount Analytical
    • Rosemount Analytical (2002). Water and wastewater industry application data sheet, PN 4950-10.
    • (2002)
  • 7
    • 0033820052 scopus 로고    scopus 로고
    • Potable water quality and membrane technology
    • Taylor, J. and Hong, S. (2000). Potable water quality and membrane technology. J. Lab. Med., 31, 563-568.
    • (2000) J. Lab. Med. , vol.31 , pp. 563-568
    • Taylor, J.1    Hong, S.2
  • 10
    • 0030830966 scopus 로고    scopus 로고
    • Design and validation of a low-cost paper-based oxygen electrode
    • Yang, Z., Suzuki, H., Sasaki, S. and Karube, I. (1997). Design and validation of a low-cost paper-based oxygen electrode. Anal. Lett., 30, 1797-1807.
    • (1997) Anal. Lett. , vol.30 , pp. 1797-1807
    • Yang, Z.1    Suzuki, H.2    Sasaki, S.3    Karube, I.4
  • 11
    • 21044457511 scopus 로고    scopus 로고
    • Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on prussian blue layer
    • Zhu, J., Zhu, Z., Lai, Z., Wang, R., Guo, X., Wu, X., Zhang, G., Zhang, Z., Wang, Y. and Chen, Z. (2002). Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on prussian blue layer. Sensors, 2, 127-136.
    • (2002) Sensors , vol.2 , pp. 127-136
    • Zhu, J.1    Zhu, Z.2    Lai, Z.3    Wang, R.4    Guo, X.5    Wu, X.6    Zhang, G.7    Zhang, Z.8    Wang, Y.9    Chen, Z.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.