메뉴 건너뛰기




Volumn 39, Issue 1-3, 1997, Pages 380-385

Smart-sensor approach for a fibre-optic-based residual chlorine monitor

Author keywords

Chlorine; Monolithic spectrometers; Optical fibres; Ultraviolet spectroscopy

Indexed keywords

CHEMICAL WATER TREATMENT; CHLORINE; IONS; OPTICAL FIBERS; PH; ULTRAVIOLET SPECTROSCOPY;

EID: 0031084447     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(97)80238-9     Document Type: Article
Times cited : (37)

References (17)
  • 1
    • 0017943945 scopus 로고
    • Determination of residual chlorine in water with computer automation and a residual-chlorine electrode
    • L.P. Rigdon, G.J. Moody and L.W. Frazer, Determination of residual chlorine in water with computer automation and a residual-chlorine electrode, Anal. Chem., 50 (1978) 465-468.
    • (1978) Anal. Chem. , vol.50 , pp. 465-468
    • Rigdon, L.P.1    Moody, G.J.2    Frazer, L.W.3
  • 2
    • 0000230358 scopus 로고
    • Determination of chlorine in water by luminol chemiluminescence
    • D.F. Marino and J.D. Ingle, Jr., Determination of chlorine in water by luminol chemiluminescence, Anal. Chem., 53 (1981) 455-458.
    • (1981) Anal. Chem. , vol.53 , pp. 455-458
    • Marino, D.F.1    Ingle J.D., Jr.2
  • 4
    • 0020708650 scopus 로고
    • Continuous flow determination of free chlorine in water
    • T. Aoki and M. Munemori, Continuous flow determination of free chlorine in water, Anal. Chem., 55 (1983) 209-212.
    • (1983) Anal. Chem. , vol.55 , pp. 209-212
    • Aoki, T.1    Munemori, M.2
  • 6
    • 0027553073 scopus 로고
    • Design and implementation of a fibre-optic-based residual chlorine monitor
    • Z. Mouaziz, R. Briggs, I. Hamilton and K.T.V. Grattan, Design and implementation of a fibre-optic-based residual chlorine monitor, Sensors and Actuators B, 11 (1993) 431-440.
    • (1993) Sensors and Actuators B , vol.11 , pp. 431-440
    • Mouaziz, Z.1    Briggs, R.2    Hamilton, I.3    Grattan, K.T.V.4
  • 7
    • 0041853783 scopus 로고    scopus 로고
    • Hanau
    • 2 lamps, Hanau, 1996.
    • (1996) 2 Lamps
  • 8
    • 0000416414 scopus 로고
    • Interspecimen comparison of the refractive index of fused silica
    • L.H. Malitson, Interspecimen comparison of the refractive index of fused silica, J. Opt. Soc. Am., 55 (1965) 1205-1209.
    • (1965) J. Opt. Soc. Am. , vol.55 , pp. 1205-1209
    • Malitson, L.H.1
  • 10
    • 0027150807 scopus 로고
    • Optical fibers with enhanced performance for excimer laser power transmission
    • H. Fabian, U. Grzesik, G. Hillrichs and W. Neu, Optical fibers with enhanced performance for excimer laser power transmission, Proc. SPIE, Vol. 1693, 1993, p. 24.
    • (1993) Proc. SPIE , vol.1693 , pp. 24
    • Fabian, H.1    Grzesik, U.2    Hillrichs, G.3    Neu, W.4
  • 13
    • 0020957611 scopus 로고
    • Determination of phosphorus in natural waters by long-capillary-cell absorption spectrometry
    • W. Lei, K. Fujiwara and K. Fuwa, Determination of phosphorus in natural waters by long-capillary-cell absorption spectrometry, Anal. Chem., 55 (1983) 951-955.
    • (1983) Anal. Chem. , vol.55 , pp. 951-955
    • Lei, W.1    Fujiwara, K.2    Fuwa, K.3
  • 15
    • 0003683811 scopus 로고    scopus 로고
    • Carl Zeiss, Oberkochen, Germany
    • MMS UV/VIS, Product Information, Carl Zeiss, Oberkochen, Germany (1996).
    • (1996) Product Information
  • 17
    • 0041353036 scopus 로고    scopus 로고
    • Binary encoded 2nd differential spectrometry using UV-Vis spectra data and neural networks in the estimation of species type and concentration
    • accepted for publication
    • N. Benjathapanun, W.J.O. Boyle and K.T.V. Grattan, Binary encoded 2nd differential spectrometry using UV-Vis spectra data and neural networks in the estimation of species type and concentration, IEE Proc. A, Sci. Meas. Technol., accepted for publication, 1996.
    • (1996) IEE Proc. A, Sci. Meas. Technol.
    • Benjathapanun, N.1    Boyle, W.J.O.2    Grattan, K.T.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.