메뉴 건너뛰기




Volumn 55, Issue 1, 2006, Pages 1-8

A comparative study of most suitable miniplate fixation for mandibular symphysis fracture using a finite element model

Author keywords

Finite element analysis; Mandibular symphysis fracture; Mechanical stress; Miniplate

Indexed keywords

ADULT; ARTICLE; BONE PLATE; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; FINITE ELEMENT ANALYSIS; HUMAN; INTERMETHOD COMPARISON; MALE; MANDIBLE FRACTURE; MECHANICAL STRESS; MOLAR TOOTH;

EID: 33646570584     PISSN: 00229717     EISSN: 00229717     Source Type: Journal    
DOI: 10.2302/kjm.55.1     Document Type: Article
Times cited : (22)

References (25)
  • 1
    • 13944256323 scopus 로고    scopus 로고
    • Maxillofacial fractures. Analysis of demographic distribution and treatment in 2901 patients (25-year experience)
    • Erol B, Tanrikulu R, Görgün B: Maxillofacial fractures. Analysis of demographic distribution and treatment in 2901 patients (25-year experience). J Craniomaxillofac Surg 2004; 32: 308-313
    • (2004) J Craniomaxillofac Surg , vol.32 , pp. 308-313
    • Erol, B.1    Tanrikulu, R.2    Görgün, B.3
  • 3
    • 13944282152 scopus 로고    scopus 로고
    • Use of resorbable plates and screws in pediatric facial fractures
    • Eppley BL: Use of resorbable plates and screws in pediatric facial fractures. J Oral Maxillofac Surg 2005; 63: 385-391
    • (2005) J Oral Maxillofac Surg , vol.63 , pp. 385-391
    • Eppley, B.L.1
  • 4
    • 0036287227 scopus 로고    scopus 로고
    • Treatment of mandible fractures using bioabsorbable plates
    • Kim YK, Kim SG: Treatment of mandible fractures using bioabsorbable plates. Plast Reconstr Surg 2002; 110: 25-31
    • (2002) Plast Reconstr Surg , vol.110 , pp. 25-31
    • Kim, Y.K.1    Kim, S.G.2
  • 5
    • 0037381719 scopus 로고    scopus 로고
    • Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures
    • Cox T, Kohn MW, Impelluso T: Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures. J Oral Maxillofac Surg 2003; 61: 481-487
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 481-487
    • Cox, T.1    Kohn, M.W.2    Impelluso, T.3
  • 6
    • 0242319477 scopus 로고    scopus 로고
    • Analysis of complications in fractures of the mandibular angle - A study with finite element computation and evaluation of data of 277 patients
    • Feller KU, Schneider M, Hlawitschka M, Pfeifer G, Lauer G, Eckelt U: Analysis of complications in fractures of the mandibular angle - a study with finite element computation and evaluation of data of 277 patients. J Craniomaxillofac Surg 2003; 31: 290-295
    • (2003) J Craniomaxillofac Surg , vol.31 , pp. 290-295
    • Feller, K.U.1    Schneider, M.2    Hlawitschka, M.3    Pfeifer, G.4    Lauer, G.5    Eckelt, U.6
  • 7
    • 0036887196 scopus 로고    scopus 로고
    • A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process
    • Wagner A, Krach W, Schicho K, Undt G, Ploder O, Ewers R: A 3-dimensional finite-element analysis investigating the biomechanical behavior of the mandible and plate osteosynthesis in cases of fractures of the condylar process. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2002; 94: 678-686
    • (2002) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.94 , pp. 678-686
    • Wagner, A.1    Krach, W.2    Schicho, K.3    Undt, G.4    Ploder, O.5    Ewers, R.6
  • 8
    • 0026743087 scopus 로고
    • Changing trends with mandibular fractures: A review of 1,067 cases
    • Fridrich KL, Pena-Velasco G, Olson RA: Changing trends with mandibular fractures: a review of 1,067 cases. J Oral Maxillofac Surg 1992; 50: 586-589
    • (1992) J Oral Maxillofac Surg , vol.50 , pp. 586-589
    • Fridrich, K.L.1    Pena-Velasco, G.2    Olson, R.A.3
  • 9
    • 0034785051 scopus 로고    scopus 로고
    • 5196 mandible fractures among 4381 active duty army soldiers, 1980 to 1998
    • Boole JR, Holtel M, Amoroso P, Yore M: 5196 mandible fractures among 4381 active duty army soldiers, 1980 to 1998. Laryngoscope. 2001; 111: 1691-1696
    • (2001) Laryngoscope , vol.111 , pp. 1691-1696
    • Boole, J.R.1    Holtel, M.2    Amoroso, P.3    Yore, M.4
  • 10
    • 0026793354 scopus 로고
    • Different patterns of mandibular fractures in children. An analysis of 220 fractures in 157 patients
    • Thoren H, Iizuka T, Hallikainen D, Lindqvist C: Different patterns of mandibular fractures in children. An analysis of 220 fractures in 157 patients. J Craniomaxillofac Surg 1992; 20: 292-296
    • (1992) J Craniomaxillofac Surg , vol.20 , pp. 292-296
    • Thoren, H.1    Iizuka, T.2    Hallikainen, D.3    Lindqvist, C.4
  • 12
    • 0038375999 scopus 로고    scopus 로고
    • Complications of mandibular fractures in an urban teaching center
    • Lamphier J, Ziccardi V, Ruvo A, Janel M: Complications of mandibular fractures in an urban teaching center. J Oral Maxillofac Surg 2003; 61: 745-749
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 745-749
    • Lamphier, J.1    Ziccardi, V.2    Ruvo, A.3    Janel, M.4
  • 13
    • 0036592503 scopus 로고    scopus 로고
    • Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models
    • Nagasao T, Kobayashi M, Tsuchiya Y, Kaneko T, Nakajima T: Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models. J Craniomaxillofac Surg 2002; 30: 170-177
    • (2002) J Craniomaxillofac Surg , vol.30 , pp. 170-177
    • Nagasao, T.1    Kobayashi, M.2    Tsuchiya, Y.3    Kaneko, T.4    Nakajima, T.5
  • 14
    • 0030208125 scopus 로고    scopus 로고
    • Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis
    • Sertgöz A, Güvener S: Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent 1996; 76: 165-169
    • (1996) J Prosthet Dent , vol.76 , pp. 165-169
    • Sertgöz, A.1    Güvener, S.2
  • 15
    • 0033506539 scopus 로고    scopus 로고
    • Finite-element-analysis of different screw-diameters in the sagittal split osteotomy of the mandible
    • Maurer P, Holweg S, Schubert J: Finite-element-analysis of different screw-diameters in the sagittal split osteotomy of the mandible. J Craniomaxillofac Surg 1999; 27: 365-372
    • (1999) J Craniomaxillofac Surg , vol.27 , pp. 365-372
    • Maurer, P.1    Holweg, S.2    Schubert, J.3
  • 18
    • 0036140978 scopus 로고    scopus 로고
    • A biomechanical evaluation of mandibular condyle fracture plating techniques
    • Haug RH, Peterson GP, Goltz M: A biomechanical evaluation of mandibular condyle fracture plating techniques. J Oral Maxillofac Surg 2002; 60: 73-80
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 73-80
    • Haug, R.H.1    Peterson, G.P.2    Goltz, M.3
  • 19
    • 0034786799 scopus 로고    scopus 로고
    • A biomechanical evaluation of mandibular angle fracture plating techniques
    • Haug RH, Fattahi TT, Goltz M: A biomechanical evaluation of mandibular angle fracture plating techniques. J Oral Maxillofac Surg 2001; 59: 1199-1210
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 1199-1210
    • Haug, R.H.1    Fattahi, T.T.2    Goltz, M.3
  • 20
    • 0038158252 scopus 로고    scopus 로고
    • Finite element analysis of the stresses around fixtures in various reconstructed mandibular models - Part II (effect of horizontal load)
    • Nagasao T, Kobayashi M, Tsuchiya Y, Kaneko T, Nakajima T: Finite element analysis of the stresses around fixtures in various reconstructed mandibular models - part II (effect of horizontal load). J Craniomaxillofac Surg 2003; 31: 168-175
    • (2003) J Craniomaxillofac Surg , vol.31 , pp. 168-175
    • Nagasao, T.1    Kobayashi, M.2    Tsuchiya, Y.3    Kaneko, T.4    Nakajima, T.5
  • 21
    • 16544369932 scopus 로고    scopus 로고
    • A three-dimensional computer model of the human mandible in two simulated standard trauma situations
    • Gallas Torreira M, Fernandez JR: A three-dimensional computer model of the human mandible in two simulated standard trauma situations. J Craniomaxillofac Surg 2004; 32: 303-307
    • (2004) J Craniomaxillofac Surg , vol.32 , pp. 303-307
    • Gallas Torreira, M.1    Fernandez, J.R.2
  • 23
    • 0027381478 scopus 로고
    • Hydroxyapatite ceramic coating for bone implant fixation. Mechanical and histological studies in dogs
    • Soballe K: Hydroxyapatite ceramic coating for bone implant fixation. Mechanical and histological studies in dogs. Acta Orthop Scand Suppl 1993; 255: 1-58
    • (1993) Acta Orthop Scand Suppl , vol.255 , pp. 1-58
    • Soballe, K.1
  • 24
    • 0033917129 scopus 로고    scopus 로고
    • Nonunion of the mandible: An analysis of contributing factors
    • Mathog RH, Toma V, Clayman L, Wolf S: Nonunion of the mandible: an analysis of contributing factors. J Oral Maxillofac Surg 2000; 58: 746-752
    • (2000) J Oral Maxillofac Surg , vol.58 , pp. 746-752
    • Mathog, R.H.1    Toma, V.2    Clayman, L.3    Wolf, S.4
  • 25
    • 33646546591 scopus 로고
    • Microvascular changes during osseous healing after mandibular segmental resection
    • in Japanese
    • Nakajima M, Okada S: Microvascular changes during osseous healing after mandibular segmental resection. Nihon kokugeka gakkaishi 1994; 40: 1049-1057 (in Japanese)
    • (1994) Nihon Kokugeka Gakkaishi , vol.40 , pp. 1049-1057
    • Nakajima, M.1    Okada, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.