Influence of neuromuscular blockade on the airway leak pressure of the ProSeal® laryngeal mask airway;Auswirkung einer neuromuskulären blockade auf den leckagedruck der ProSeal®-kehlkopfmaske

Author keywords

Airway leak pressure; General anaesthesia; Laryngeal mask airway; Neuromuscular blockade; Ventilation

Indexed keywords

FENTANYL; HYDROGEN; INTRAVENOUS ANESTHETIC AGENT; OXYGEN; PROPOFOL; RAMIFENTANIL; RUCURONIUM; UNCLASSIFIED DRUG;

EID: 33646467065     PISSN: 09392661     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2005-921200     Document Type: Article
Times cited : (27)

References (31)
  • 1
    • 0030028038 scopus 로고    scopus 로고
    • Survey of laryngeal mask usage in 11 910 patients: Saftey and efficacy for conventional and nonconventional usage
    • Verghese C, Brimacombe J. Survey of laryngeal mask usage in 11 910 patients: Saftey and efficacy for conventional and nonconventional usage. Anesth Analg 1996; 82: 129-133
    • (1996) Anesth Analg , vol.82 , pp. 129-133
    • Verghese, C.1    Brimacombe, J.2
  • 2
    • 0034743737 scopus 로고    scopus 로고
    • Is it safe to artificially ventilate a paralysed patient through the laryngeal mask? the jury is still out
    • Sidaras G, Hunter JM. Is it safe to artificially ventilate a paralysed patient through the laryngeal mask? The jury is still out. (Editorial) Brit J Anaesth 2001; 86: 749-753
    • (2001) Brit J Anaesth , vol.86 , pp. 749-753
    • Sidaras, G.1    Hunter, J.M.2
  • 3
    • 0037285815 scopus 로고    scopus 로고
    • The LMA. Laparoscopic surgery and the obese patient - Can vs should
    • Cooper RM. The LMA. Laparoscopic surgery and the obese patient - can vs should. (Editorial) Can J Anesth 2003; 50: 5-10
    • (2003) Can J Anesth , vol.50 , pp. 5-10
    • Cooper, R.M.1
  • 4
    • 0027289045 scopus 로고
    • Anaesthesia for gynaecological laparoscopy - A comparison between the laryngeal mask airway and tracheal intubation
    • Swann DG, Spens H, Edwards SA, Chestnut RJ. Anaesthesia for gynaecological laparoscopy - a comparison between the laryngeal mask airway and tracheal intubation. Anaesthesia 1993; 48: 431-434
    • (1993) Anaesthesia , vol.48 , pp. 431-434
    • Swann, D.G.1    Spens, H.2    Edwards, S.A.3    Chestnut, R.J.4
  • 5
    • 0030798883 scopus 로고    scopus 로고
    • Laryngeal mask airway and the incidence of regurgitation during gynecological laparoscopies
    • Bopat PP, Verghese C. Laryngeal mask airway and the incidence of regurgitation during gynecological laparoscopies. Anesth Analg 1997; 85: 139-143
    • (1997) Anesth Analg , vol.85 , pp. 139-143
    • Bopat, P.P.1    Verghese, C.2
  • 6
    • 0033836077 scopus 로고    scopus 로고
    • Gastric distension and ventilation during laparoscopic cholecystectomy: LMA-Classic vs tracheal intubation
    • Maltby JR, Beriault MT, Watson NC, Fick GH. Gastric distension and ventilation during laparoscopic cholecystectomy: LMA-Classic vs tracheal intubation. Can J Anaesth 2000; 47: 622-626
    • (2000) Can J Anaesth , vol.47 , pp. 622-626
    • Maltby, J.R.1    Beriault, M.T.2    Watson, N.C.3    Fick, G.H.4
  • 7
    • 0034110143 scopus 로고    scopus 로고
    • The LMA ProSeal - A laryngeal mask with an oesophageal vent
    • Brain AIJ, Verghese C, Strube PJ. The LMA ProSeal - a laryngeal mask with an oesophageal vent. Brit J Anaesth 2000; 84: 650-654
    • (2000) Brit J Anaesth , vol.84 , pp. 650-654
    • Brain, A.I.J.1    Verghese, C.2    Strube, P.J.3
  • 8
    • 0036275968 scopus 로고    scopus 로고
    • ProSeal versus Classic laryngeal mask airway for positive pressure ventilation during laparoscopic cholecystectomy
    • Lu PP, Brimacombe J, Yang C, Shyr M. ProSeal versus Classic laryngeal mask airway for positive pressure ventilation during laparoscopic cholecystectomy. Brit J Anaesth 2002; 88: 824-827
    • (2002) Brit J Anaesth , vol.88 , pp. 824-827
    • Lu, P.P.1    Brimacombe, J.2    Yang, C.3    Shyr, M.4
  • 9
    • 0037282718 scopus 로고    scopus 로고
    • LMA-Classic and LMA-ProSeal are effective alternatives to endotracheal intubation for gynaecological laparoscopy
    • Maltby JR, Beriault MT, Watson NC, Liepert DJ, Pick GH. LMA-Classic and LMA-ProSeal are effective alternatives to endotracheal intubation for gynaecological laparoscopy. Can J Anaesth 2003; 50: 71-77
    • (2003) Can J Anaesth , vol.50 , pp. 71-77
    • Maltby, J.R.1    Beriault, M.T.2    Watson, N.C.3    Liepert, D.J.4    Pick, G.H.5
  • 11
    • 16844377320 scopus 로고    scopus 로고
    • The ProSeal laryngeal mask airway and the laryngeal tube Suction for ventilation in gynaecological patients undergoing laparoscopic surgery
    • Roth H, Genzwuerker HV, Rothhaas A, Flinteis T, Schmeck J. The ProSeal laryngeal mask airway and the laryngeal tube Suction for ventilation in gynaecological patients undergoing laparoscopic surgery. Eur J Anaesthesiol 2005; 22: 117-122
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 117-122
    • Roth, H.1    Genzwuerker, H.V.2    Rothhaas, A.3    Flinteis, T.4    Schmeck, J.5
  • 12
    • 0036895543 scopus 로고    scopus 로고
    • Maximum minute ventilation test for the ProSeal laryngeal mask airway
    • Stix MS, ÓConnor CJ, jr. Maximum minute ventilation test for the ProSeal laryngeal mask airway. Anesth Analg 2002; 95: 1782-1787
    • (2002) Anesth Analg , vol.95 , pp. 1782-1787
    • Stix, M.S.1    Óconnor Jr., C.J.2
  • 15
    • 0034952061 scopus 로고    scopus 로고
    • Airway protection with the ProSeal laryngeal mask airway: A case report
    • Brimacombe J, Keller C. Airway protection with the ProSeal laryngeal mask airway: a case report. Anaesth Intensive Care 2001; 29: 288-91
    • (2001) Anaesth Intensive Care , vol.29 , pp. 288-291
    • Brimacombe, J.1    Keller, C.2
  • 16
    • 0036189461 scopus 로고    scopus 로고
    • The ProSeal laryngeal mask airway
    • Cook TM, Nolan JP. The ProSeal laryngeal mask airway. Anaesthesia 2002; 57: 288-289
    • (2002) Anaesthesia , vol.57 , pp. 288-289
    • Cook, T.M.1    Nolan, J.P.2
  • 17
    • 0036274658 scopus 로고    scopus 로고
    • Protection against aspiration with the Proseal laryngeal mask airway
    • De Silva KK, Young P. Protection against aspiration with the Proseal laryngeal mask airway. Anaesth Intensive Care 2002; 30: 391
    • (2002) Anaesth Intensive Care , vol.30 , pp. 391
    • De Silva, K.K.1    Young, P.2
  • 18
    • 0036098954 scopus 로고    scopus 로고
    • Aspiration prevented by the ProSeal™ laryngeal mask airway: A case report
    • Evans NR, Llewellyn RL, Gardner SV, James MFM. Aspiration prevented by the ProSeal™ laryngeal mask airway: a case report. Can J Anesth 2002; 49: 413-416
    • (2002) Can J Anesth , vol.49 , pp. 413-416
    • Evans, N.R.1    Llewellyn, R.L.2    Gardner, S.V.3    James, M.F.M.4
  • 19
    • 0037285949 scopus 로고    scopus 로고
    • Protection from aspiration with the LMA-ProSeal™ after vomiting: A case report
    • Mark DA. Protection from aspiration with the LMA-ProSeal™ after vomiting: a case report. Can J Anesth 2003; 50: 78-80
    • (2003) Can J Anesth , vol.50 , pp. 78-80
    • Mark, D.A.1
  • 20
    • 0033795102 scopus 로고    scopus 로고
    • Does the ProSeal™ laryngeal mask airway prevent aspiration of regurgitated fluid? A cadaveric study
    • Keller C, Brimacombe J, Kleinsasser A, Loeckinger A. Does the ProSeal™ laryngeal mask airway prevent aspiration of regurgitated fluid? A cadaveric study. Anesth Analg 2000; 91: 1017-1020
    • (2000) Anesth Analg , vol.91 , pp. 1017-1020
    • Keller, C.1    Brimacombe, J.2    Kleinsasser, A.3    Loeckinger, A.4
  • 21
    • 33646470653 scopus 로고    scopus 로고
    • Maintenance phase
    • Brimacombe J (Hrsg). Philadelphia: WB Saunders
    • Brimacombe J. Maintenance phase. In: Brimacombe J (Hrsg). Laryngeal mask anesthesia. Philadelphia: WB Saunders, 2004: 241-263
    • (2004) Laryngeal Mask Anesthesia , pp. 241-263
    • Brimacombe, J.1
  • 22
    • 33744962638 scopus 로고    scopus 로고
    • Seal with the respiratory and gastrointestinal tracts
    • Brimacombe J (Hrsg). Philadelphia: WB Saunders
    • Brimacombe J. Seal with the respiratory and gastrointestinal tracts. In: Brimacombe J (Hrsg). Laryngeal mask anesthesia. Philadelphia: WB Saunders, 2004: 137-152
    • (2004) Laryngeal Mask Anesthesia , pp. 137-152
    • Brimacombe, J.1
  • 23
    • 33646477513 scopus 로고
    • Hals
    • Leonhardt H, Tillmann B, Töndury G, Zilles K (Hrsg). Stuttgart, New York: Georg Thieme Verlag
    • Tillmann B. Hals. In: Leonhardt H, Tillmann B, Töndury G, Zilles K (Hrsg). Anatomie des Menschen. Stuttgart, New York: Georg Thieme Verlag, 1987: 655-671
    • (1987) Anatomie des Menschen , pp. 655-671
    • Tillmann, B.1
  • 24
    • 0344614456 scopus 로고
    • Transport and mixing of food in the alimentary tract
    • Guyton AC (Hrsg). Philadelphia: WB Saunders
    • Guyton AC. Transport and mixing of food in the alimentary tract. In: Guyton AC (Hrsg). Textbook of Medical Physiology. Philadelphia: WB Saunders, 1991: 698-708
    • (1991) Textbook of Medical Physiology , pp. 698-708
    • Guyton, A.C.1
  • 25
    • 0027947405 scopus 로고
    • Onset and duration of rocuronium and succinylcholine at the adductor pollids and laryngeal adductor muscles in anesthetized humans
    • Wrigth PMC, Caldwell JE, Miller RD. Onset and duration of rocuronium and succinylcholine at the adductor pollids and laryngeal adductor muscles in anesthetized humans. Anesthesiology 1994; 81: 1110-1115
    • (1994) Anesthesiology , vol.81 , pp. 1110-1115
    • Wrigth, P.M.C.1    Caldwell, J.E.2    Miller, R.D.3
  • 26
    • 33646481595 scopus 로고    scopus 로고
    • LMA-ProSeal™
    • Nicosia, Zypern: The Laryngeal Mask Company Limited
    • LMA-ProSeal™. Anleitungshandbuch. Nicosia, Zypern: The Laryngeal Mask Company Limited, 2001
    • (2001) Anleitungshandbuch
  • 27
    • 0027528467 scopus 로고
    • A proposed fiber-optic scoring system to standardize the assessment of the laryngeal mask airway position
    • Brimacombe J, Berry A. A proposed fiber-optic scoring system to standardize the assessment of the laryngeal mask airway position. Anesth Analg 1993; 76: 457
    • (1993) Anesth Analg , vol.76 , pp. 457
    • Brimacombe, J.1    Berry, A.2
  • 28
    • 0032908319 scopus 로고    scopus 로고
    • Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients
    • Keller C, Brimacombe J, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Brit J Anaesth 1999; 82: 286-287
    • (1999) Brit J Anaesth , vol.82 , pp. 286-287
    • Keller, C.1    Brimacombe, J.2    Keller, K.3    Morris, R.4
  • 29
    • 17144457036 scopus 로고    scopus 로고
    • Neuromuskuläres monitoring
    • Fuchs-Buder T, Mencke T. Neuromuskuläres Monitoring. Anaesthesist 2001; 50: 129-138
    • (2001) Anaesthesist , vol.50 , pp. 129-138
    • Fuchs-Buder, T.1    Mencke, T.2
  • 30
    • 1642288214 scopus 로고    scopus 로고
    • Alternativen zur endotrachealen Intubation: Eine Frage der statistischen Analyse?
    • peters J. Alternativen zur endotrachealen Intubation: eine Frage der statistischen Analyse? (Editorial). Anästhesiol Intensivmed Notfallmed Schmerzther 2004; 39: 125-126
    • (2004) Anästhesiol Intensivmed Notfallmed Schmerzther , vol.39 , pp. 125-126
    • Peters, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.