메뉴 건너뛰기




Volumn 13, Issue 2, 2006, Pages 353-360

Calibration methods of carbon nanotube gas sensor for partial discharge detection in SF 6

Author keywords

Calibration; Carbon nanotube; Dielectrophoresis; Gas sensor; Gas insulated switchgear; NO 2; Partial discharge; SF 6

Indexed keywords

DIELECTROPHORESIS; GAS-INSULATED SWITCHGEAR; NO2;

EID: 33646413964     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2006.1624280     Document Type: Article
Times cited : (29)

References (18)
  • 1
    • 0344081237 scopus 로고    scopus 로고
    • Status review on partial discharge measurement techniques in gas-insulated switchgear/lines
    • I. A. Metwally, "Status Review on Partial Discharge Measurement Techniques in Gas-insulated Switchgear/Lines", J. Electric Power Syst. Res., Vol. 69, pp. 25-36, 2004.
    • (2004) J. Electric Power Syst. Res. , vol.69 , pp. 25-36
    • Metwally, I.A.1
  • 2
  • 3
    • 0041846625 scopus 로고    scopus 로고
    • 2 mixture under negative DC coronas in the presence of water vapour or oxygen
    • 2 Mixture under Negative DC Coronas in the Presence of Water Vapour or Oxygen", J. Phys. D: Appl. Phys., Vol. 36, pp. 1558-1564, 2003.
    • (2003) J. Phys. D: Appl. Phys. , vol.36 , pp. 1558-1564
    • Diaz, J.1    Casanovas, A.M.2    Casanovas, J.3
  • 4
    • 0022706324 scopus 로고
    • 6 arcing byproduct detectors for field use in gas-insulated switchgear
    • 6 Arcing Byproduct Detectors for Field Use in Gas-insulated Switchgear", IEEE Trans. Power Del., Vol. 1, pp. 81-86, 1986.
    • (1986) IEEE Trans. Power Del. , vol.1 , pp. 81-86
    • Braun, J.M.1    Chu, F.Y.2
  • 5
    • 33646396681 scopus 로고    scopus 로고
    • On-site diagnostic of the decomposition of sulfur hexafluoride due to partial discharges
    • The Netherlands, Paper No. O.29.01
    • th ISH, The Netherlands, 2003, Paper No. O.29.01.
    • (2003) th ISH
    • Wember, M.1    Peier, D.2
  • 6
    • 0032108136 scopus 로고    scopus 로고
    • 6-insulated equipments by using an OTDR method and corner cube prisms coated with dye films
    • 6-insulated Equipments by Using an OTDR Method and Corner Cube Prisms Coated with Dye Films", Sens. and Actuat. B, Vol. 50, pp. 140-144, 1998.
    • (1998) Sens. and Actuat. B , vol.50 , pp. 140-144
    • Kawamura, M.1    Ishii, K.2    Sato, S.3
  • 9
    • 0038262624 scopus 로고    scopus 로고
    • Toward large arrays of multiplex functionalized carbon nanotube sensors for highly sensitive and selective molecular detection
    • P. Qi, O. Vermesh, M. Grecu, A. Javey, Q. Wang, H. Dai, S. Peng and K. J. Cho, "Toward Large Arrays of Multiplex Functionalized Carbon Nanotube Sensors for Highly Sensitive and Selective Molecular Detection", Nano Lett., Vol. 3, pp. 347-351, 2003.
    • (2003) Nano Lett. , vol.3 , pp. 347-351
    • Qi, P.1    Vermesh, O.2    Grecu, M.3    Javey, A.4    Wang, Q.5    Dai, H.6    Peng, S.7    Cho, K.J.8
  • 11
    • 33748498942 scopus 로고    scopus 로고
    • A wireless, passive carbon nanotube-based gas sensor
    • K. G. Ong, K. Zeng and C. A. Grimes, "A Wireless, Passive Carbon Nanotube-based Gas Sensor", IEEE Sensors J., Vol. 2, pp. 82-88, 2002.
    • (2002) IEEE Sensors J. , vol.2 , pp. 82-88
    • Ong, K.G.1    Zeng, K.2    Grimes, C.A.3
  • 12
    • 79958225431 scopus 로고    scopus 로고
    • Carbon nanotube-based resonant-circuit sensor for ammonia
    • S. Chopra, A. Pham, J. Gaillard, A. Parker and M. Rao, "Carbon Nanotube-based Resonant-circuit Sensor for Ammonia", Appl. Phys. Lett., Vol. 80, pp. 4632-4634, 2002.
    • (2002) Appl. Phys. Lett. , vol.80 , pp. 4632-4634
    • Chopra, S.1    Pham, A.2    Gaillard, J.3    Parker, A.4    Rao, M.5
  • 13
    • 0242573687 scopus 로고    scopus 로고
    • Fabrication of a carbon nanotube-based gas sensor using dielectrophoresis and its application for ammonia detection by impedance spectroscopy
    • J. Suehiro, G. Zhou and M. Hara, "Fabrication of a Carbon Nanotube-based Gas Sensor Using Dielectrophoresis and Its Application for Ammonia Detection by Impedance Spectroscopy", J. Phys. D: Appl. Phys., Vol. 36, pp. L109-L114, 2003.
    • (2003) J. Phys. D: Appl. Phys. , vol.36
    • Suehiro, J.1    Zhou, G.2    Hara, M.3
  • 14
    • 14744289658 scopus 로고    scopus 로고
    • 6 gas using a carbon nanotube-based gas sensor
    • 6 Gas Using a Carbon Nanotube-based Gas Sensor", Sens. Actual. B, Vol. 105, pp. 164-169, 2005.
    • (2005) Sens. Actual. B , vol.105 , pp. 164-169
    • Suehiro, J.1    Zhou, G.2    Hara, M.3
  • 17
    • 0033345559 scopus 로고    scopus 로고
    • Quantitative estimation of biological cell concentration suspended in aqueous medium by using dielectrophoretic impedance measurement method
    • J. Suehiro, R. Yatsunami, R. Hamada and M. Hara, "Quantitative Estimation of Biological Cell Concentration Suspended in Aqueous Medium by Using Dielectrophoretic Impedance Measurement Method", J. Phys. D: Appl. Phys., Vol. 32, pp. 2814-2820, 1999.
    • (1999) J. Phys. D: Appl. Phys. , vol.32 , pp. 2814-2820
    • Suehiro, J.1    Yatsunami, R.2    Hamada, R.3    Hara, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.