Volumn 41, Issue 2, 2006, Pages 189-197

Quantitative assessment of patellar cartilage volume and thickness at 3.0 tesla comparing a 3D-fast low angle shot versus a 3D-true fast imaging with steady-state precession sequence for reproducibility

Author keywords

3.0 T; Cartilage; FLASH; MRI; Quantitation; Reproducibility; Thickness; TrueFISP; Volume

Indexed keywords

ADULT; ARTICLE; CARTILAGE; CONTROLLED STUDY; DATA ANALYSIS; DISEASE COURSE; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; INTERMETHOD COMPARISON; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOARTHRITIS; PATELLA; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SIGNAL NOISE RATIO; STATISTICAL SIGNIFICANCE; STEADY STATE; THREE DIMENSIONAL IMAGING; ARTICULAR CARTILAGE; COMPARATIVE STUDY; HISTOLOGY; KNEE; METHODOLOGY; OBSERVER VARIATION; REPRODUCIBILITY; VALIDATION STUDY;

EID: 33646364348     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000195837.32417.f9     Document Type: Article
Times cited : (43)

References (32)
  • 1
    • 0034521633 scopus 로고    scopus 로고
    • Arthrose Histologie und pathogenetische Ansätze
    • Sulzbacher I. Arthrose Histologie und pathogenetische Ansätze. Radiologe. 2000;40:1126-1133.
    • (2000) Radiologe , vol.40 , pp. 1126-1133
    • Sulzbacher, I.1
  • 3
    • 14544307938 scopus 로고    scopus 로고
    • Future treatment of osteoarthritis
    • Baker CL Jr, Ferguson CM. Future treatment of osteoarthritis. Orthopedics. 2005;28:227-234.
    • (2005) Orthopedics , vol.28 , pp. 227-234
    • Baker Jr., C.L.1    Ferguson, C.M.2
  • 4
    • 15944424324 scopus 로고    scopus 로고
    • Disease modifying therapies for osteoarthritis: Current status
    • Fajardo M, Di Cesare PE. Disease modifying therapies for osteoarthritis: current status. Drugs Aging. 2005;22:141-161.
    • (2005) Drugs Aging , vol.22 , pp. 141-161
    • Fajardo, M.1    Di Cesare, P.E.2
  • 5
    • 7244221687 scopus 로고    scopus 로고
    • Current treatment modalities for cartilage defects at the knee-results of a nation-wide survey of surgical trauma and orthopaedic clinics in Germany
    • Luring C, Anders S, Bathis H, et al. Current treatment modalities for cartilage defects at the knee-results of a nation-wide survey of surgical trauma and orthopaedic clinics in Germany. Z Orthop Ihre Grenzgebiete. 2004;142:546-552.
    • (2004) Z Orthop Ihre Grenzgebiete , vol.142 , pp. 546-552
    • Luring, C.1    Anders, S.2    Bathis, H.3
  • 7
    • 0030004409 scopus 로고    scopus 로고
    • Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy
    • Disler DG, McCauley TR, Kelman CG, et al. Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: comparison with standard MR imaging and arthroscopy. Am J Roentgenol. 1996;67:127-132.
    • (1996) Am J Roentgenol , vol.67 , pp. 127-132
    • Disler, D.G.1    McCauley, T.R.2    Kelman, C.G.3
  • 8
    • 0031866441 scopus 로고    scopus 로고
    • Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging
    • Eckstein F, Schnier N, Hauber M, et al. Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging. Clin Orthop Relat Res. 1998;352:137-139.
    • (1998) Clin Orthop Relat Res , vol.352 , pp. 137-139
    • Eckstein, F.1    Schnier, N.2    Hauber, M.3
  • 9
    • 0034021715 scopus 로고    scopus 로고
    • Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment if thin cartilage layers
    • Graichen H, Springer V, Flaman T, et al. Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment if thin cartilage layers. Osteoarthritis Cartilage. 2000;8:106-114.
    • (2000) Osteoarthritis Cartilage , vol.8 , pp. 106-114
    • Graichen, H.1    Springer, V.2    Flaman, T.3
  • 10
    • 28744457445 scopus 로고    scopus 로고
    • Noninvasive study of human cartilage structures by MRI
    • Eckstein F. Noninvasive study of human cartilage structures by MRI. Methods Mol Med. 2004;101:191-217.
    • (2004) Methods Mol Med , vol.101 , pp. 191-217
    • Eckstein, F.1
  • 11
    • 0042329497 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging of articular cartilage in knee osteoarthritis
    • Raynauld J-P. Quantitative magnetic resonance imaging of articular cartilage in knee osteoarthritis. Curr Opin Rheumatol. 2003;15:647-650.
    • (2003) Curr Opin Rheumatol , vol.15 , pp. 647-650
    • Raynauld, J.-P.1
  • 12
    • 10744224242 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging evaluation of knee osteoarthritis progression over two years and correlation with clinical symptoms and radiologic changes
    • Raynauld J-P, Martel-Pelletier J, Berthiaume M-J, et al. Quantitative magnetic resonance imaging evaluation of knee osteoarthritis progression over two years and correlation with clinical symptoms and radiologic changes. Arthritis Rheum. 2004;50:476-487.
    • (2004) Arthritis Rheum , vol.50 , pp. 476-487
    • Raynauld, J.-P.1    Martel-Pelletier, J.2    Berthiaume, M.-J.3
  • 13
    • 1542343975 scopus 로고    scopus 로고
    • Quantitative assessment of cartilage status in osteoarthritis by quantitative magnetic resonance imaging. Technical validation for use in analysis of cartilage volume and further morphological parameters
    • Graichen H, von Eisenhart-Rothe R, Vogl T, et al. Quantitative assessment of cartilage status in osteoarthritis by quantitative magnetic resonance imaging. Technical validation for use in analysis of cartilage volume and further morphological parameters. Arthritis Rheum. 2004;50:811-816.
    • (2004) Arthritis Rheum , vol.50 , pp. 811-816
    • Graichen, H.1    Von Eisenhart-Rothe, R.2    Vogl, T.3
  • 14
    • 0036894786 scopus 로고    scopus 로고
    • The determinant of change in patella cartilage volume in osteoarthritic knees
    • Cicuttini F, Wlutka A, Wang Y, et al. The determinant of change in patella cartilage volume in osteoarthritic knees. J Rheumatol. 2002;29:2615-2619.
    • (2002) J Rheumatol , vol.29 , pp. 2615-2619
    • Cicuttini, F.1    Wlutka, A.2    Wang, Y.3
  • 15
    • 0345579709 scopus 로고    scopus 로고
    • Cartilage loss over two years in femorotibial osteoarthritis
    • Glaser C, Draeger M, Englmeier KH, et al. Cartilage loss over two years in femorotibial osteoarthritis. Radiology. 2002;225(Suppl):330.
    • (2002) Radiology , vol.225 , Issue.SUPPL. , pp. 330
    • Glaser, C.1    Draeger, M.2    Englmeier, K.H.3
  • 16
    • 0035014414 scopus 로고    scopus 로고
    • Optimization and validation of a rapid high-resolution T1-w 3D-FLASH water excitation MRI sequence for the quantitative assessment of articular cartilage volume and thickness
    • Glaser C, Faber S, Eckstein F, et al. Optimization and validation of a rapid high-resolution T1-w 3D-FLASH water excitation MRI sequence for the quantitative assessment of articular cartilage volume and thickness. Magn Reson Imaging. 2001;19:177-185.
    • (2001) Magn Reson Imaging , vol.19 , pp. 177-185
    • Glaser, C.1    Faber, S.2    Eckstein, F.3
  • 17
    • 0034021715 scopus 로고    scopus 로고
    • Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment of thin cartilage layers
    • Graichen H, Springer V, Flaman T, et al. Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment of thin cartilage layers. Osteoarthritis Cartilage. 2000;8:106-114.
    • (2000) Osteoarthritis Cartilage , vol.8 , pp. 106-114
    • Graichen, H.1    Springer, V.2    Flaman, T.3
  • 18
    • 0037306841 scopus 로고    scopus 로고
    • Rapid MR imaging of articular cartilage with steady state free precession and multipoint fat-water separation
    • Reeder SB, Pelc NJ, Alley MT, et al. Rapid MR imaging of articular cartilage with steady state free precession and multipoint fat-water separation. Am J Roentgenol. 2003;180:357-362.
    • (2003) Am J Roentgenol , vol.180 , pp. 357-362
    • Reeder, S.B.1    Pelc, N.J.2    Alley, M.T.3
  • 19
    • 0028059347 scopus 로고
    • Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: Optimization and validation
    • Peterfy CG, van Dijke CF, Janzen DL, et al. Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation. Radiology. 1994;192:485-491.
    • (1994) Radiology , vol.192 , pp. 485-491
    • Peterfy, C.G.1    Van Dijke, C.F.2    Janzen, D.L.3
  • 20
    • 14944365023 scopus 로고    scopus 로고
    • MR imaging of articular cartilage at 1.5 and 3.0 T: Comparison of SPGR and SSFP sequences
    • Kornaat PR, Reeder SB, Koo S, et al. MR imaging of articular cartilage at 1.5 and 3.0 T: comparison of SPGR and SSFP sequences. Osteoarthritis Cartilage. 2005;13:338-344.
    • (2005) Osteoarthritis Cartilage , vol.13 , pp. 338-344
    • Kornaat, P.R.1    Reeder, S.B.2    Koo, S.3
  • 21
    • 13244252640 scopus 로고    scopus 로고
    • In vivo cartilage deformation after different types of activity and its dependence on physical training status
    • Eckstein F, Lemberger B, Gratzke C, et al. In vivo cartilage deformation after different types of activity and its dependence on physical training status. Ann Rheum Dis. 2005;64:291-295.
    • (2005) Ann Rheum Dis , vol.64 , pp. 291-295
    • Eckstein, F.1    Lemberger, B.2    Gratzke, C.3
  • 22
    • 0031961129 scopus 로고    scopus 로고
    • Effects of physical exercise on cartilage volume and thickness in vivo - An MR imaging study
    • Eckstein F, Tieschky M, Faber S, et al. Effects of physical exercise on cartilage volume and thickness in vivo - an MR imaging study. Radiology. 1998;207:243-248.
    • (1998) Radiology , vol.207 , pp. 243-248
    • Eckstein, F.1    Tieschky, M.2    Faber, S.3
  • 24
    • 0001434472 scopus 로고
    • Hyaline articular cartilage: Relaxation times, pulse sequence parameters and MR appearance at 15 T
    • Chalkias SM, Pozzi-Mucelli RS, Pozzi-Mucelli M, et al. Hyaline articular cartilage: relaxation times, pulse sequence parameters and MR appearance at 15 T. Eur Radiol. 1994;4:353-359.
    • (1994) Eur Radiol , vol.4 , pp. 353-359
    • Chalkias, S.M.1    Pozzi-Mucelli, R.S.2    Pozzi-Mucelli, M.3
  • 25
    • 0033957730 scopus 로고    scopus 로고
    • Human articular cartilage: Influence of aging and early symptomatic degeneration on the spatial variation of T2 - Preliminary findings at 3 T
    • Mosher TJ, Dardzinski BJ, Smith MB. Human articular cartilage: influence of aging and early symptomatic degeneration on the spatial variation of T2 - preliminary findings at 3 T. Radiology. 2000;214:259-266.
    • (2000) Radiology , vol.214 , pp. 259-266
    • Mosher, T.J.1    Dardzinski, B.J.2    Smith, M.B.3
  • 26
    • 0030921706 scopus 로고    scopus 로고
    • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: Development of a computational method
    • Losch A, Eckstein F, Haubner M, et al. A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: development of a computational method. Magn Reson Imaging. 1997;15:795-804.
    • (1997) Magn Reson Imaging , vol.15 , pp. 795-804
    • Losch, A.1    Eckstein, F.2    Haubner, M.3
  • 27
    • 0030967791 scopus 로고    scopus 로고
    • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 2: Validation using CT arthrography
    • Haubner M, Eckstein F, Schnier M, et al. A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 2: validation using CT arthrography. Magn Reson Imaging. 1997;15:805-813.
    • (1997) Magn Reson Imaging , vol.15 , pp. 805-813
    • Haubner, M.1    Eckstein, F.2    Schnier, M.3
  • 28
    • 0032999913 scopus 로고    scopus 로고
    • Determination of 3D cartilage thickness data from MR imaging: Computational method and reproducibility in the living
    • Stammberger T, Eckstein F, Englmeier KH, et al. Determination of 3D cartilage thickness data from MR imaging: computational method and reproducibility in the living. Magn Reson Med. 1999;41:529-536.
    • (1999) Magn Reson Med , vol.41 , pp. 529-536
    • Stammberger, T.1    Eckstein, F.2    Englmeier, K.H.3
  • 29
    • 0035095998 scopus 로고    scopus 로고
    • Inter-individual variability and correlation among morphological parameters of knee joint cartilage plates: Analysis with three-dimensional MR imaging
    • Eckstein F, Winzheimer M, Hohe J, et al. Inter-individual variability and correlation among morphological parameters of knee joint cartilage plates: analysis with three-dimensional MR imaging. Osteoarthritis Cartilage. 2001;9:101-111.
    • (2001) Osteoarthritis Cartilage , vol.9 , pp. 101-111
    • Eckstein, F.1    Winzheimer, M.2    Hohe, J.3
  • 30
    • 0034232664 scopus 로고    scopus 로고
    • Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume
    • Cicuttini F, Forbes A, Asbeutah A, et al. Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume. J Orthop Res. 2000;18:580-584.
    • (2000) J Orthop Res , vol.18 , pp. 580-584
    • Cicuttini, F.1    Forbes, A.2    Asbeutah, A.3
  • 31
    • 11444249274 scopus 로고    scopus 로고
    • Measuring cartilage morphology with quantitative magnetic resonance imaging
    • Eckstein F, Glaser C. Measuring cartilage morphology with quantitative magnetic resonance imaging. Sem Musculoskeletal Radiol. 2004;8:341-365.
    • (2004) Sem Musculoskeletal Radiol , vol.8 , pp. 341-365
    • Eckstein, F.1    Glaser, C.2
  • 32
    • 7044222795 scopus 로고    scopus 로고
    • Magnetic resonance imaging of knee cartilage using a water selective balanced steady-state free precession sequence
    • Kornaat PR, Doornbos J, van der Molen AJ, et al. Magnetic resonance imaging of knee cartilage using a water selective balanced steady-state free precession sequence. J Magn Reson Imaging. 2004;20:850-856.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 850-856
    • Kornaat, P.R.1    Doornbos, J.2    Van Der Molen, A.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.