메뉴 건너뛰기




Volumn 13, Issue 2-3, 2006, Pages 649-659

Semiactive control strategy for smart base isolation utilizing absolute acceleration information

Author keywords

Acceleration; Benchmark problem; MR damper; Semiactive control; Slip force level; Smart base isolated building

Indexed keywords

APPROXIMATION THEORY; CONTROL SYSTEM ANALYSIS; DAMPING; ENERGY DISSIPATION; HYSTERESIS;

EID: 33646346347     PISSN: 15452255     EISSN: 15452263     Source Type: Journal    
DOI: 10.1002/stc.103     Document Type: Article
Times cited : (18)

References (25)
  • 6
    • 4444336140 scopus 로고    scopus 로고
    • Dynamic modeling of large-scale magnetorheological damper systems for civil engineering application
    • Yang G, Spencer BF, Jung H-J, Carlson JD. Dynamic modeling of large-scale magnetorheological damper systems for civil engineering application. Journal of Engineering Mechanics (ASCE) 2004; 130(9):1107-1114.
    • (2004) Journal of Engineering Mechanics (ASCE) , vol.130 , Issue.9 , pp. 1107-1114
    • Yang, G.1    Spencer, B.F.2    Jung, H.-J.3    Carlson, J.D.4
  • 7
    • 0000406319 scopus 로고
    • Abating earthquake effects on buildings by active slip brace devices
    • Akbay Z, Aktan HM. Abating earthquake effects on buildings by active slip brace devices. Shock and Vibration 1995; 2:133-142.
    • (1995) Shock and Vibration , vol.2 , pp. 133-142
    • Akbay, Z.1    Aktan, H.M.2
  • 9
    • 0031103454 scopus 로고    scopus 로고
    • Modulated homogeneous friction: A semi-active damping strategy
    • Inaudi J. Modulated homogeneous friction: a semi-active damping strategy. Earthquake Engineering and Structural Dynamics 1997; 26:361-376.
    • (1997) Earthquake Engineering and Structural Dynamics , vol.26 , pp. 361-376
    • Inaudi, J.1
  • 10
    • 0040749045 scopus 로고    scopus 로고
    • Control of seismically excited cable-stayed bridge using resetting semiactive stiffness damper
    • He WL, Agrawal AK, Mahmoud K. Control of seismically excited cable-stayed bridge using resetting semiactive stiffness damper. Journal of Bridge Engineering (ASCE) 2001; 6(6):376-384.
    • (2001) Journal of Bridge Engineering (ASCE) , vol.6 , Issue.6 , pp. 376-384
    • He, W.L.1    Agrawal, A.K.2    Mahmoud, K.3
  • 11
    • 0035424423 scopus 로고    scopus 로고
    • Control of wind-excited truss tower using semiactive friction damper
    • Xu YL, Qu WL, Chen ZH. Control of wind-excited truss tower using semiactive friction damper. Journal of Structural Engineering (ASCE) 2001; 127(8):861-868.
    • (2001) Journal of Structural Engineering (ASCE) , vol.127 , Issue.8 , pp. 861-868
    • Xu, Y.L.1    Qu, W.L.2    Zh, C.3
  • 12
    • 11144296363 scopus 로고    scopus 로고
    • Applications of some semiactive control systems to benchmark cable-stayed bridge
    • Agrawal AK, Yang JN, He WL. Applications of some semiactive control systems to benchmark cable-stayed bridge. Journal of Structural Engineering (ASCE) 2003; 129(7):884-894.
    • (2003) Journal of Structural Engineering (ASCE) , vol.129 , Issue.7 , pp. 884-894
    • Agrawal, A.K.1    Yang, J.N.2    He, W.L.3
  • 13
    • 10044245211 scopus 로고    scopus 로고
    • Novel semiactive friction controller for linear structures against earthquakes
    • He WL, Agrawal AK, Yang JN. Novel semiactive friction controller for linear structures against earthquakes. Journal of Structural Engineering (ASCE) 2003; 129(7):941-950.
    • (2003) Journal of Structural Engineering (ASCE) , vol.129 , Issue.7 , pp. 941-950
    • He, W.L.1    Agrawal, A.K.2    Yang, J.N.3
  • 14
    • 2342426279 scopus 로고    scopus 로고
    • Predictive control of seismic structures with semi-active friction dampers
    • Lu L-Y. Predictive control of seismic structures with semi-active friction dampers. Earthquake Engineering and Structural Dynamics 2004; 33:647-668.
    • (2004) Earthquake Engineering and Structural Dynamics , vol.33 , pp. 647-668
    • Lu, L.-Y.1
  • 15
    • 13844268976 scopus 로고    scopus 로고
    • Semiactive control of the 20-story benchmark building with piezoelectric friction dampers
    • Chen G, Chen C. Semiactive control of the 20-story benchmark building with piezoelectric friction dampers. Journal of Engineering Mechanics (ASCE) 2004; 130(4):393-400.
    • (2004) Journal of Engineering Mechanics (ASCE) , vol.130 , Issue.4 , pp. 393-400
    • Chen, G.1    Chen, C.2
  • 18
    • 11144265316 scopus 로고    scopus 로고
    • Semiactive structural-control based on variable slip-force level dampers
    • Nishitani A, Nitta Y, Ikeda Y. Semiactive structural-control based on variable slip-force level dampers. Journal of Structural Engineering (ASCE) 2003; 129(7):933-940.
    • (2003) Journal of Structural Engineering (ASCE) , vol.129 , Issue.7 , pp. 933-940
    • Nishitani, A.1    Nitta, Y.2    Ikeda, Y.3
  • 19
  • 21
    • 33646345214 scopus 로고    scopus 로고
    • Phase i smart base isolated benchmark building - Sample controllers for linear isolation system: Part II
    • in print
    • Nagarajaiah S, Narasimhan S. Phase I smart base isolated benchmark building - sample controllers for linear isolation system: part II. Journal of Structural Control and Health Monitoring, 2006; in print.
    • (2006) Journal of Structural Control and Health Monitoring
    • Nagarajaiah, S.1    Narasimhan, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.