메뉴 건너뛰기




Volumn 109, Issue 4, 2006, Pages 328-331

Percutaneous reduction and stabilization of a dislocated acetabular fracture. Case report;Perkutane reposition und stabilisierung einer dislozierten acetabulumfraktur. Ein fallbericht

Author keywords

Acetabular fracture; Intraoperative imaging; Siremobil Iso C3D fluoroscope

Indexed keywords

ACETABULUM FRACTURE; ADULT; ARTICLE; BONE STRUCTURE; CASE REPORT; CLINICAL FEATURE; COMPUTER ASSISTED TOMOGRAPHY; DEVICE; DISEASE COURSE; EXTERNAL FIXATOR; FLUOROSCOPY; FRACTURE DISLOCATION; FRACTURE FIXATION; FRACTURE REDUCTION; HUMAN; INTRAOPERATIVE PERIOD; MALE; MORBIDITY; PLASTIC SURGERY;

EID: 33646245887     PISSN: 01775537     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00113-006-1059-8     Document Type: Article
Times cited : (6)

References (11)
  • 1
    • 0036391047 scopus 로고    scopus 로고
    • Closed reduction and percutaneous fixation of anterior column acetabular fractures
    • Crowl AC, Kahler DM (2002) Closed reduction and percutaneous fixation of anterior column acetabular fractures. Comput Aided Surg 7: 169-178
    • (2002) Comput Aided Surg , vol.7 , pp. 169-178
    • Crowl, A.C.1    Kahler, D.M.2
  • 2
    • 0026589215 scopus 로고
    • Percutaneous screw fixation of acetabular fractures with CT guidance: Preliminary results of a new technique
    • Gay SB, Sistrom C, Wang GJ et al. (1992) Percutaneous screw fixation of acetabular fractures with CT guidance: preliminary results of a new technique. Am J Roentgenol 158: 819-822
    • (1992) Am J Roentgenol , vol.158 , pp. 819-822
    • Gay, S.B.1    Sistrom, C.2    Wang, G.J.3
  • 3
    • 7944233793 scopus 로고    scopus 로고
    • Transverse acetabular fracture: Hybrid minimal access and percutaneous CT-navigated fixation
    • Gross T, Jacob AL, Messmer P (2004) Transverse acetabular fracture: hybrid minimal access and percutaneous CT-navigated fixation. Am J Roentgenol 183: 1000-1002
    • (2004) Am J Roentgenol , vol.183 , pp. 1000-1002
    • Gross, T.1    Jacob, A.L.2    Messmer, P.3
  • 4
    • 16644395064 scopus 로고    scopus 로고
    • Displaced anterior column acetabular fracture: Closed reduction and percutaneous CT-navigated fixation
    • Huegli RW, Staedele H, Messmer P (2004) Displaced anterior column acetabular fracture: closed reduction and percutaneous CT-navigated fixation. Acta Radiol 45: 618-621
    • (2004) Acta Radiol , vol.45 , pp. 618-621
    • Huegli, R.W.1    Staedele, H.2    Messmer, P.3
  • 5
    • 0033677091 scopus 로고    scopus 로고
    • Coronal acetabular fractures: The anterior approach in computer-tomography-navigated minimally invasive percutaneous fixation
    • Jacob AL, Suhm N, Kaim A (2000) Coronal acetabular fractures: the anterior approach in computer-tomography-navigated minimally invasive percutaneous fixation. Cardiovasc Intervent Radiol 23:327-331
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 327-331
    • Jacob, A.L.1    Suhm, N.2    Kaim, A.3
  • 7
    • 0030466101 scopus 로고    scopus 로고
    • Fractures of the Azetabulum: Accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury
    • Matta JM (1996) Fractures of the Azetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am 78: 1632-1645
    • (1996) J Bone Joint Surg Am , vol.78 , pp. 1632-1645
    • Matta, J.M.1
  • 8
    • 0032087236 scopus 로고    scopus 로고
    • Percutaneous fixation of acetabular fractures
    • Matta JM (1998) Percutaneous fixation of acetabular fractures. J Orthop Trauma 12: 370
    • (1998) J Orthop Trauma , vol.12 , pp. 370
    • Matta, J.M.1
  • 9
    • 0031278144 scopus 로고    scopus 로고
    • Percutaneous fluoroscopic screw fixation of acetabular fractures
    • Parker PJ, Copeland C (1997) Percutaneous fluoroscopic screw fixation of acetabular fractures. Injury 28: 597-600
    • (1997) Injury , vol.28 , pp. 597-600
    • Parker, P.J.1    Copeland, C.2
  • 10
    • 0342854153 scopus 로고    scopus 로고
    • Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the Azetabulum
    • Starr AJ, Jones AL, Reinert CM, Borer DS (2001) Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the Azetabulum. Injury 32(Suppl 1): 45-50
    • (2001) Injury , vol.32 , Issue.1 SUPPL. , pp. 45-50
    • Starr, A.J.1    Jones, A.L.2    Reinert, C.M.3    Borer, D.S.4
  • 11
    • 0033954604 scopus 로고    scopus 로고
    • A transverse acetabular non-union treated with computer-assisted percutaneous internal fixation. A case report
    • Zura RD, Kahler DM (2000) A transverse acetabular non-union treated with computer-assisted percutaneous internal fixation. A case report. J Bone Joint Surg Am 82: 219-224
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 219-224
    • Zura, R.D.1    Kahler, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.