메뉴 건너뛰기




Volumn 13, Issue 6, 2006, Pages 701-712

Physical Evaluation of the Weighted Feldkamp Algorithms Applied to the 256-Detector Row CT Scanner for Volumetric Cine Imaging

Author keywords

computed tomography (CT); Cone beam; four dimensional; image quality; temporal resolution

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT; CINERADIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; DEVICE; EVALUATION; HEART; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; LUNG BLOOD VESSEL; MOTION; NOISE; PHANTOM; PRIORITY JOURNAL; VOLUMETRY;

EID: 33646176962     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2006.03.002     Document Type: Article
Times cited : (2)

References (22)
  • 1
    • 0020030616 scopus 로고
    • Optimal short scan convolution reconstruction for fanbeam CT
    • Parker D.L. Optimal short scan convolution reconstruction for fanbeam CT. Med Phys 9 (1982) 254-257
    • (1982) Med Phys , vol.9 , pp. 254-257
    • Parker, D.L.1
  • 2
    • 0035176903 scopus 로고    scopus 로고
    • Heart-rate adaptive optimization of spatial and temporal resolution for ECG-gated multi-slice spiral CT of the heart
    • Flohr T., and Ohnesorge B. Heart-rate adaptive optimization of spatial and temporal resolution for ECG-gated multi-slice spiral CT of the heart. J Comput Assist Tomogr 25 (2001) 907-923
    • (2001) J Comput Assist Tomogr , vol.25 , pp. 907-923
    • Flohr, T.1    Ohnesorge, B.2
  • 3
    • 0033863629 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    • Kachelrieß M., Ulzheimer S., and Kalender W.A. ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys 27 (2000) 1881-1902
    • (2000) Med Phys , vol.27 , pp. 1881-1902
    • Kachelrieß, M.1    Ulzheimer, S.2    Kalender, W.A.3
  • 4
    • 0036032234 scopus 로고    scopus 로고
    • A novel reconstruction scheme for cardiac volume imaging with MSCT providing cone correction
    • Bruder H., Stierstorfer K., Ohnesorge B., et al. A novel reconstruction scheme for cardiac volume imaging with MSCT providing cone correction. Proc SPIE 4684 (2001) 60-71
    • (2001) Proc SPIE , vol.4684 , pp. 60-71
    • Bruder, H.1    Stierstorfer, K.2    Ohnesorge, B.3
  • 5
    • 10744231515 scopus 로고    scopus 로고
    • Development and performance evaluation of the first model of 4D CT-scanner
    • Endo M., Mori S., Tsunoo T., et al. Development and performance evaluation of the first model of 4D CT-scanner. IEEE Trans Nucl Sci 50 (2003) 1667-1671
    • (2003) IEEE Trans Nucl Sci , vol.50 , pp. 1667-1671
    • Endo, M.1    Mori, S.2    Tsunoo, T.3
  • 7
    • 3042661990 scopus 로고    scopus 로고
    • Physical performance evaluation of a 256-detector row CT-scanner for 4-dimensional imaging
    • Mori S., Endo M., Tsunoo T., et al. Physical performance evaluation of a 256-detector row CT-scanner for 4-dimensional imaging. Med Phys 31 (2004) 1348-1356
    • (2004) Med Phys , vol.31 , pp. 1348-1356
    • Mori, S.1    Endo, M.2    Tsunoo, T.3
  • 8
    • 0034876879 scopus 로고    scopus 로고
    • Large area 2-dimensional detector for real-time 3-dimensional CT (4D CT)
    • Saito Y., Aradate H., Igarashi K., et al. Large area 2-dimensional detector for real-time 3-dimensional CT (4D CT). Proc SPIE 4320 (2001) 775-782
    • (2001) Proc SPIE , vol.4320 , pp. 775-782
    • Saito, Y.1    Aradate, H.2    Igarashi, K.3
  • 9
    • 0033993737 scopus 로고    scopus 로고
    • A method for including redundant data in computed tomography
    • Silver M.D. A method for including redundant data in computed tomography. Med Phys 27 (2000) 773-774
    • (2000) Med Phys , vol.27 , pp. 773-774
    • Silver, M.D.1
  • 10
    • 0037394932 scopus 로고    scopus 로고
    • Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT
    • Taguchi K. Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT. Med Phys 30 (2003) 640-650
    • (2003) Med Phys , vol.30 , pp. 640-650
    • Taguchi, K.1
  • 11
    • 0034117652 scopus 로고    scopus 로고
    • High temporal resolution for multislice helical computed tomography
    • Taguchi K., and Anno H. High temporal resolution for multislice helical computed tomography. Med Phys 27 (2000) 861-872
    • (2000) Med Phys , vol.27 , pp. 861-872
    • Taguchi, K.1    Anno, H.2
  • 12
    • 0028397603 scopus 로고
    • Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits
    • Kudo H., and Saito Y. Derivation and implementation of a cone-beam reconstruction algorithm for nonplanar orbits. IEEE Trans Med Imaging 13 (1994) 196-211
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 196-211
    • Kudo, H.1    Saito, Y.2
  • 13
    • 0028738292 scopus 로고
    • A new cone beam reconstruction algorithm and its application to circular orbits
    • Hu H. A new cone beam reconstruction algorithm and its application to circular orbits. Proc SPIE 2163 (1994) 223-234
    • (1994) Proc SPIE , vol.2163 , pp. 223-234
    • Hu, H.1
  • 14
    • 0030866638 scopus 로고    scopus 로고
    • Nonstationary noise characteristics of the helical scan and its impact on image quality and artifact
    • Hsieh J. Nonstationary noise characteristics of the helical scan and its impact on image quality and artifact. Med Phys 24 (1997) 1375-1384
    • (1997) Med Phys , vol.24 , pp. 1375-1384
    • Hsieh, J.1
  • 15
    • 0142025634 scopus 로고    scopus 로고
    • Half-scan fan-beam computed tomography with improved noise and resolution properties
    • Yu L., and Pan X. Half-scan fan-beam computed tomography with improved noise and resolution properties. Med Phys 30 (2003) 2629-2637
    • (2003) Med Phys , vol.30 , pp. 2629-2637
    • Yu, L.1    Pan, X.2
  • 16
    • 0027006277 scopus 로고    scopus 로고
    • Three-dimensional helical-scan computed tomography using cone-beam projections
    • Kudo H., and Saito T. Three-dimensional helical-scan computed tomography using cone-beam projections. Syst Comput Jpn 23 (2002) 75-82
    • (2002) Syst Comput Jpn , vol.23 , pp. 75-82
    • Kudo, H.1    Saito, T.2
  • 17
    • 0020764170 scopus 로고
    • An inversion fomula for cone-beam reconstruction
    • Tuy H.K. An inversion fomula for cone-beam reconstruction. SIAM J Math 43 (1983) 546-552
    • (1983) SIAM J Math , vol.43 , pp. 546-552
    • Tuy, H.K.1
  • 18
    • 0022026907 scopus 로고
    • Image reconstruction methods
    • Smith B.D. Image reconstruction methods. IEEE Trans Med Imaging 4 (1985) 14-25
    • (1985) IEEE Trans Med Imaging , vol.4 , pp. 14-25
    • Smith, B.D.1
  • 19
    • 0002018761 scopus 로고
    • Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform
    • Herman G.T., Louis A.K., and Natterer F. (Eds), Springer-Verlag, New York
    • Grangeat P. Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform. In: Herman G.T., Louis A.K., and Natterer F. (Eds). Mathematical Methods in Tomography, Lecture Notes in Mathematics 1497 (1991), Springer-Verlag, New York 66-97
    • (1991) Mathematical Methods in Tomography, Lecture Notes in Mathematics 1497 , pp. 66-97
    • Grangeat, P.1
  • 20
    • 0033999358 scopus 로고    scopus 로고
    • Advanced single-slice rebining in cone-beam spiral CT
    • Kachelrieß M., Schaler S., and Kalender W.A. Advanced single-slice rebining in cone-beam spiral CT. Med Phys 27 (2000) 754-772
    • (2000) Med Phys , vol.27 , pp. 754-772
    • Kachelrieß, M.1    Schaler, S.2    Kalender, W.A.3
  • 21
    • 0034188460 scopus 로고    scopus 로고
    • Exact Radon rebinning algorithm for the long object problem in helical cone-beam CT
    • Schaller S., Noo F., Sauer F., Tam K.C., Lauritsh G., and Flohr T. Exact Radon rebinning algorithm for the long object problem in helical cone-beam CT. IEEE Trans Med Imaging 19 (2000) 361-375
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 361-375
    • Schaller, S.1    Noo, F.2    Sauer, F.3    Tam, K.C.4    Lauritsh, G.5    Flohr, T.6
  • 22
    • 24644502799 scopus 로고    scopus 로고
    • Clinical potentials for dynamic contrast-enhanced hepatic volumetric cine imaging with the prototype 256-detector row CT-scanner
    • Mori S., Obata T., Kishimoto R., et al. Clinical potentials for dynamic contrast-enhanced hepatic volumetric cine imaging with the prototype 256-detector row CT-scanner. AJR Am J Roentegenol 185 (2005) 253-256
    • (2005) AJR Am J Roentegenol , vol.185 , pp. 253-256
    • Mori, S.1    Obata, T.2    Kishimoto, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.