메뉴 건너뛰기




Volumn 4684 I, Issue , 2002, Pages 60-73

A novel reconstruction scheme for cardiac volume imaging with MSCT providing cone correction

Author keywords

Cardiac volume imaging; Cone correction; ECG correlated reconstruction; Multi slice Computed Tomography; Multisector imaging; Spiral scanning

Indexed keywords

ALGORITHMS; COMPUTATIONAL METHODS; COMPUTERIZED TOMOGRAPHY; CORRELATION METHODS; DATA ACQUISITION; ELECTROCARDIOGRAPHY; MATHEMATICAL MODELS; MEDICAL IMAGING;

EID: 0036032234     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.467228     Document Type: Conference Paper
Times cited : (6)

References (22)
  • 1
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport and continuous scanner rotation
    • W.A. Kalender, W. Seissler, E. Klotz, P. Vock, "Spiral volumetric CT with single-breath-hold technique, continuous transport and continuous scanner rotation," Radiology, vol. 176, pp. 181-183, 1990.
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3    Vock, P.4
  • 2
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C.R. Crawford, K.F. King, "Computed tomography scanning with simultaneous patient translation," Med. Phys., vol. 17, no. 6, pp. 967-982, 1990.
    • (1990) Med. Phys. , vol.17 , Issue.6 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 4
    • 0029612812 scopus 로고
    • Thin-section threee-dimensional spiral CT: Is isotropic imaging possible?
    • W.A. Kalender, "Thin-section threee-dimensional spiral CT: is isotropic imaging possible?," Radiology, vol. 197, pp. 578-580, 1995.
    • (1995) Radiology , vol.197 , pp. 578-580
    • Kalender, W.A.1
  • 7
    • 0034257866 scopus 로고    scopus 로고
    • Spiral interpolation algorithm for multi-slice spiral CT. Part II: Performance evaluation
    • T. Fuchs, S. Schaller, J. Krause, T. Flohr, W. Kalender, "Spiral Interpolation Algorithm for Multi-Slice Spiral CT. Part II: Performance Evaluation", IEEE Transactions on Medical Imaging, vol. 19 No. 9, pp. 835-847, 2000.
    • (2000) IEEE Transactions on Medical Imaging , vol.19 , Issue.9 , pp. 835-847
    • Fuchs, T.1    Schaller, S.2    Krause, J.3    Flohr, T.4    Kalender, W.5
  • 8
    • 0035312512 scopus 로고    scopus 로고
    • Noninvasive detection and evaluation of atherosclerotic coronary plaques with multi-slice computed tomography
    • S. Schroeder, A. Kopp, A. Baumbach et al. "Noninvasive Detection and Evaluation of Atherosclerotic Coronary Plaques With Multi-slice Computed Tomography", JACC, vol. 37 No. 5, pp. 1430-1435, 2001.
    • (2001) JACC , vol.37 , Issue.5 , pp. 1430-1435
    • Schroeder, S.1    Kopp, A.2    Baumbach, A.3
  • 10
    • 0032593848 scopus 로고    scopus 로고
    • High temporal resolution volume heart imaging with multirow computed tomography
    • H. Bruder, S. Schaller, B. Ohnesorge, T. Mertelmeier, "High temporal resolution volume heart imaging with multirow computed tomography ", SPIE Med. Imag. Conf., vol. 3661, pp. 420-432, 1999.
    • (1999) SPIE Med. Imag. Conf. , vol.3661 , pp. 420-432
    • Bruder, H.1    Schaller, S.2    Ohnesorge, B.3    Mertelmeier, T.4
  • 11
    • 0035176903 scopus 로고    scopus 로고
    • Heart-rate adaptive optimization of spatial and temporal resolution for ECG-gated multislice spiral CT of the heart
    • T. Flohr, B. Ohnesorge, "Heart-Rate Adaptive Optimization of Spatial and Temporal Resolution for ECG-Gated Multislice Spiral CT of the Heart", JCAT vol. 25 No. 6, 2001.
    • (2001) JCAT , vol.25 , Issue.6
    • Flohr, T.1    Ohnesorge, B.2
  • 12
    • 0031695422 scopus 로고    scopus 로고
    • Cone-beam filtered-backprojection algorithm for truncated helical data
    • H. Kudo, F. Noo, M. Defrise, "Cone-beam filtered-backprojection algorithm for truncated helical data," Phys. Med. Biol., vol. 43, pp. 2885-2909, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2885-2909
    • Kudo, H.1    Noo, F.2    Defrise, M.3
  • 15
  • 16
    • 0027967106 scopus 로고
    • Half-scan cone-beam X-ray microtomography formula
    • G. Wang, Y. Liu, T. Lin, P. Cheng, "Half-scan cone-beam X-ray microtomography formula," Scanning, vol. 16, pp. 216-220, 1994.
    • (1994) Scanning , vol.16 , pp. 216-220
    • Wang, G.1    Liu, Y.2    Lin, T.3    Cheng, P.4
  • 17
    • 0033999358 scopus 로고    scopus 로고
    • Advanced single-slice rebinning in cone-beam spiral CT
    • M. Kachelrieß, S. Schaller, W.A. Kalender, "Advanced Single-Slice Rebinning in Cone-Beam Spiral CT", Med. Phys., vol. 27, no. 4, pp. 754-772, 2000.
    • (2000) Med. Phys. , vol.27 , Issue.4 , pp. 754-772
    • Kachelrieß, M.1    Schaller, S.2    Kalender, W.A.3
  • 19
    • 0034257868 scopus 로고    scopus 로고
    • Single-slice rebinning reconstruction in spiral cone-beam computed tomography
    • H. Bruder, M. Kachelrieß, S. Schaller, K. Stierstorfer and T. Flohr, "Single-Slice Rebinning Reconstruction in Spiral Cone-Beam Computed Tomography", IEEE Trans. Med. Imag. Vol. 19 No. 5, pp. 873-887, 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , Issue.5 , pp. 873-887
    • Bruder, H.1    Kachelrieß, M.2    Schaller, S.3    Stierstorfer, K.4    Flohr, T.5
  • 22
    • 0033753104 scopus 로고    scopus 로고
    • Cardiac imaging by means of electrocardiographically gated multisection spiral CT: Initial experience
    • B. Ohnesorge, T. Flohr; C. Becker et. al, "Cardiac Imaging by Means of Electrocardiographically Gated Multisection Spiral CT: Initial Experience", Radiology, vol. 217, pp. 564-571, 2000.
    • (2000) Radiology , vol.217 , pp. 564-571
    • Ohnesorge, B.1    Flohr, T.2    Becke, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.