-
1
-
-
0024040598
-
Myoelectric prostheses-state of the art
-
Scott R.N., and Parker P.A. Myoelectric prostheses-state of the art. J Med Eng Technol 12 (1988) 143-151
-
(1988)
J Med Eng Technol
, vol.12
, pp. 143-151
-
-
Scott, R.N.1
Parker, P.A.2
-
3
-
-
0032757925
-
Dimensional change in muscle as a control signal for powered upper limb prostheses: a pilot study
-
Kenney L.P.J., Lisitsa I., Bowker P., Heath G.H., and Howard D. Dimensional change in muscle as a control signal for powered upper limb prostheses: a pilot study. Med Eng Phys 21 (1999) 589-597
-
(1999)
Med Eng Phys
, vol.21
, pp. 589-597
-
-
Kenney, L.P.J.1
Lisitsa, I.2
Bowker, P.3
Heath, G.H.4
Howard, D.5
-
4
-
-
0029294460
-
Use of a pattern recognition technique to control a multifunctional prosthesis
-
Aghili F., and Haghpanahi M. Use of a pattern recognition technique to control a multifunctional prosthesis. J Biomed Eng 42 (1995) 504-508
-
(1995)
J Biomed Eng
, vol.42
, pp. 504-508
-
-
Aghili, F.1
Haghpanahi, M.2
-
6
-
-
0034283513
-
Fuzzy EMG classification for prosthesis control
-
Chan F.H.Y., Yang Y.S., Lam F.K., Zhang Y.T., and Parker P.A. Fuzzy EMG classification for prosthesis control. IEEE Trans Rehab Eng 8 (2000) 305-311
-
(2000)
IEEE Trans Rehab Eng
, vol.8
, pp. 305-311
-
-
Chan, F.H.Y.1
Yang, Y.S.2
Lam, F.K.3
Zhang, Y.T.4
Parker, P.A.5
-
7
-
-
0032840095
-
A hybrid approach to EMG pattern analysis for classification of arm movements using statistical and fuzzy techniques
-
Micera S., Sabatini A.M., Dario P., and Rossi B. A hybrid approach to EMG pattern analysis for classification of arm movements using statistical and fuzzy techniques. Med Eng Phys 21 (2001) 303-311
-
(2001)
Med Eng Phys
, vol.21
, pp. 303-311
-
-
Micera, S.1
Sabatini, A.M.2
Dario, P.3
Rossi, B.4
-
8
-
-
0042664129
-
A robust, real-time control scheme for multifunction myoelectric control
-
Englehart K., and Hudgins B. A robust, real-time control scheme for multifunction myoelectric control. IEEE Trans Biomed Eng 50 (2003) 848-854
-
(2003)
IEEE Trans Biomed Eng
, vol.50
, pp. 848-854
-
-
Englehart, K.1
Hudgins, B.2
-
9
-
-
0036757012
-
Control of a hand grasp neuoprosthesis using an electroencephalogram-triggered switch: demonstration of improvements in performance using wavepacket analysis
-
Heasman J.M., Scott T.R.D., Kirkup L., Flynn R.Y., Vare V.A., and Gschwind C.R. Control of a hand grasp neuoprosthesis using an electroencephalogram-triggered switch: demonstration of improvements in performance using wavepacket analysis. Med Biol Eng Comput 40 (2002) 588-593
-
(2002)
Med Biol Eng Comput
, vol.40
, pp. 588-593
-
-
Heasman, J.M.1
Scott, T.R.D.2
Kirkup, L.3
Flynn, R.Y.4
Vare, V.A.5
Gschwind, C.R.6
-
10
-
-
0035905783
-
Actions from thoughts
-
Nicolelis MA.L. Actions from thoughts. Nature 409 (2001) 403-407
-
(2001)
Nature
, vol.409
, pp. 403-407
-
-
Nicolelis, MA.L.1
-
11
-
-
0037036102
-
Direct cortical control of 3D neuroprosthetic device
-
Taylor D.M., Tillery S.I.H., and Schwartz A.B. Direct cortical control of 3D neuroprosthetic device. Science 296 (2002) 1829-1832
-
(2002)
Science
, vol.296
, pp. 1829-1832
-
-
Taylor, D.M.1
Tillery, S.I.H.2
Schwartz, A.B.3
-
12
-
-
0036271135
-
Brain-computer interfaces for communication and control
-
Wolpaw J.R., Birbaumer N., McFarland D.J., Pfurtscheller G., and Vaughan T.M. Brain-computer interfaces for communication and control. Clin Neurophysiol 113 (2002) 767-791
-
(2002)
Clin Neurophysiol
, vol.113
, pp. 767-791
-
-
Wolpaw, J.R.1
Birbaumer, N.2
McFarland, D.J.3
Pfurtscheller, G.4
Vaughan, T.M.5
-
13
-
-
33646017277
-
-
Qin L. Morphological studies on prevention of immobilization atrophy of skeletal muscle by electrical stimulation. PhD thesis, German Sports University, Cologne, F.R.G., March 1992.
-
-
-
-
14
-
-
0030906765
-
Electrical stimulation prevents immobilization atrophy in skeletal muscle of rabbits
-
Qin L., Appell H.-J., Chan K.M., and Maffuli N. Electrical stimulation prevents immobilization atrophy in skeletal muscle of rabbits. Arch Phys Med Rehab 78 (1997) 512-517
-
(1997)
Arch Phys Med Rehab
, vol.78
, pp. 512-517
-
-
Qin, L.1
Appell, H.-J.2
Chan, K.M.3
Maffuli, N.4
-
15
-
-
0021400615
-
Muscle sound
-
Oster G. Muscle sound. Sci Am 250 (1984) 108-114
-
(1984)
Sci Am
, vol.250
, pp. 108-114
-
-
Oster, G.1
-
16
-
-
0024494459
-
Recording sound from human skeletal muscle: technical and physiological aspects
-
Bolton C.F., Parkers A., Thompson T.R., Clark M.R., and Sterne C.J. Recording sound from human skeletal muscle: technical and physiological aspects. Muscle Nerve 12 (1989) 126-134
-
(1989)
Muscle Nerve
, vol.12
, pp. 126-134
-
-
Bolton, C.F.1
Parkers, A.2
Thompson, T.R.3
Clark, M.R.4
Sterne, C.J.5
-
17
-
-
0027155822
-
Muscle sound: bases for the introduction of a mechnomoygraphic signal in muscle studies
-
Orizio C. Muscle sound: bases for the introduction of a mechnomoygraphic signal in muscle studies. Crit Rev Biomed Eng 21 (1993) 201-243
-
(1993)
Crit Rev Biomed Eng
, vol.21
, pp. 201-243
-
-
Orizio, C.1
-
18
-
-
0036871997
-
Characteristics of surface mechanomyogram are dependent on development of fusion of motor units in humans
-
Yoshitake Y., Shinohara M., Ue H., and Moritani T. Characteristics of surface mechanomyogram are dependent on development of fusion of motor units in humans. J Appl Phys 93 (2002) 1744-1752
-
(2002)
J Appl Phys
, vol.93
, pp. 1744-1752
-
-
Yoshitake, Y.1
Shinohara, M.2
Ue, H.3
Moritani, T.4
-
19
-
-
0035706066
-
Cineplasty as a control input for externally-powered prosthetic components
-
Weir R.F., Heckathorne C.W., and Childress D.S. Cineplasty as a control input for externally-powered prosthetic components. J Rehab Res Dev 38 (2001) 357-363
-
(2001)
J Rehab Res Dev
, vol.38
, pp. 357-363
-
-
Weir, R.F.1
Heckathorne, C.W.2
Childress, D.S.3
-
20
-
-
0036586897
-
Tunnel cineplasty
-
Childress D.S. Tunnel cineplasty. J Rehab Res Dev 39 Suppl. (2002) 9-10
-
(2002)
J Rehab Res Dev
, vol.39
, Issue.SUPPL
, pp. 9-10
-
-
Childress, D.S.1
-
23
-
-
0036757912
-
Surface myomechanical responses recorded on a scanner galvanometer
-
Rafolt A., and Gallasch E. Surface myomechanical responses recorded on a scanner galvanometer. Med Biol Eng Comput 40 (2002) 594-599
-
(2002)
Med Biol Eng Comput
, vol.40
, pp. 594-599
-
-
Rafolt, A.1
Gallasch, E.2
-
24
-
-
0033012767
-
A biomimetic controller for a multifinger prosthesis
-
Abboudi R.L., Glass C.A., Newby N.A., Flint J.A., and Craelius W. A biomimetic controller for a multifinger prosthesis. IEEE Trans Rehab Eng 7 (1999) 121-129
-
(1999)
IEEE Trans Rehab Eng
, vol.7
, pp. 121-129
-
-
Abboudi, R.L.1
Glass, C.A.2
Newby, N.A.3
Flint, J.A.4
Craelius, W.5
-
26
-
-
18244362607
-
The bionic man: restoring mobility
-
Craelius W. The bionic man: restoring mobility. Science 295 (2002) 1018-1021
-
(2002)
Science
, vol.295
, pp. 1018-1021
-
-
Craelius, W.1
-
27
-
-
0003144993
-
Sonography of muscle
-
Van Holsbeek M.T., and Introcaso J.H. (Eds), St. Louis, Mosby
-
Van Holsbeeck M.T., and Introcaso J.H. Sonography of muscle. In: Van Holsbeek M.T., and Introcaso J.H. (Eds). Musculoskeletal ultrasound. 2nd ed. (2001), St. Louis, Mosby 23-75
-
(2001)
Musculoskeletal ultrasound. 2nd ed.
, pp. 23-75
-
-
Van Holsbeeck, M.T.1
Introcaso, J.H.2
-
28
-
-
0029096045
-
Restricted motion of the median nerve in carpal tunnel syndrome
-
Nakamichi K., and Tachibana S. Restricted motion of the median nerve in carpal tunnel syndrome. J Hand Surg 20 (1995) 460-464
-
(1995)
J Hand Surg
, vol.20
, pp. 460-464
-
-
Nakamichi, K.1
Tachibana, S.2
-
29
-
-
0033852360
-
Measuring longitudinal nerve motion using ultrasonography
-
Hough A.D., Moore A.P., and Jones M.P. Measuring longitudinal nerve motion using ultrasonography. Manual Ther 5 (2000) 173-180
-
(2000)
Manual Ther
, vol.5
, pp. 173-180
-
-
Hough, A.D.1
Moore, A.P.2
Jones, M.P.3
-
31
-
-
0029278254
-
Echographic image mean gray level changes with tissue dynamics: a system-based model study
-
Meunier J., and Bertrand M. Echographic image mean gray level changes with tissue dynamics: a system-based model study. IEEE Trans Biomed Eng 42 (1995) 403-410
-
(1995)
IEEE Trans Biomed Eng
, vol.42
, pp. 403-410
-
-
Meunier, J.1
Bertrand, M.2
-
32
-
-
0029758479
-
Tendinous movement of human muscle during voluntary contractions determined by real-time ultrasonography
-
Fukunaga T., Ito M., Ichinose Y., Kuno S., Kawakami Y., and Fukashiro S. Tendinous movement of human muscle during voluntary contractions determined by real-time ultrasonography. J Appl Physiol 81 (1996) 1430-1433
-
(1996)
J Appl Physiol
, vol.81
, pp. 1430-1433
-
-
Fukunaga, T.1
Ito, M.2
Ichinose, Y.3
Kuno, S.4
Kawakami, Y.5
Fukashiro, S.6
-
33
-
-
0033989924
-
In vivo moment arm determination using B-mode ultrasonography
-
Ito M., Akima H., and Fukunaga T. In vivo moment arm determination using B-mode ultrasonography. J Biomech 33 (2002) 215-218
-
(2002)
J Biomech
, vol.33
, pp. 215-218
-
-
Ito, M.1
Akima, H.2
Fukunaga, T.3
-
34
-
-
0036068834
-
Tensile properties of in vivo human tendinous tissue
-
Maganaris C.N. Tensile properties of in vivo human tendinous tissue. J Biomech 35 (2002) 1019-1027
-
(2002)
J Biomech
, vol.35
, pp. 1019-1027
-
-
Maganaris, C.N.1
-
35
-
-
0032619353
-
Elastography: ultrasonic estimation and imaging of the elastic properties of tissues
-
Ophir J., Alam S.K., Garra B., Kallel F., Konofagou E., Krouskop T., and Varghese T. Elastography: ultrasonic estimation and imaging of the elastic properties of tissues. Proc Inst Mech Eng 213 Part H (1999) 203-233
-
(1999)
Proc Inst Mech Eng
, vol.213
, Issue.PART H
, pp. 203-233
-
-
Ophir, J.1
Alam, S.K.2
Garra, B.3
Kallel, F.4
Konofagou, E.5
Krouskop, T.6
Varghese, T.7
-
37
-
-
33646033626
-
-
Lovelace AM, Bhagat PK, Wu VC. Apparatus for determining changes in limb volume. US Patent No. 4,383,533 (1983).
-
-
-
-
38
-
-
33646033921
-
-
Manthey JK. Method and apparatus for stimulation of posture. US Patent No. 5,433,201 (1995).
-
-
-
-
40
-
-
0034533060
-
Ultrasound study of the motion of the residual femur within a trans-femoral socket during gait
-
Convey P., and Murray K.D. Ultrasound study of the motion of the residual femur within a trans-femoral socket during gait. Prosthet Orthot Int 24 (2000) 226-232
-
(2000)
Prosthet Orthot Int
, vol.24
, pp. 226-232
-
-
Convey, P.1
Murray, K.D.2
-
41
-
-
1942486785
-
The relationship between EMG and change in thickness of transversus abdominis
-
McMeeken J.M., Beith I.D., and Newham D.J. The relationship between EMG and change in thickness of transversus abdominis. Clin Biomech 19 (2004) 337-342
-
(2004)
Clin Biomech
, vol.19
, pp. 337-342
-
-
McMeeken, J.M.1
Beith, I.D.2
Newham, D.J.3
-
42
-
-
0031834789
-
Eliminating ultrasonic interference from respiratory muscle EMG
-
Platt R.S., Kieser T.M., and Easton P.A. Eliminating ultrasonic interference from respiratory muscle EMG. Respir Physiol 113 (1998) 203-213
-
(1998)
Respir Physiol
, vol.113
, pp. 203-213
-
-
Platt, R.S.1
Kieser, T.M.2
Easton, P.A.3
-
43
-
-
0027496844
-
Ultrasound myography-application in nerve-conduction velocity assessment and muscle cooling
-
Journee H.L., et al. Ultrasound myography-application in nerve-conduction velocity assessment and muscle cooling. Ultrasound Med Biol 19 (1993) 561-566
-
(1993)
Ultrasound Med Biol
, vol.19
, pp. 561-566
-
-
Journee, H.L.1
-
44
-
-
9644274077
-
Development of a portable 3D ultrasound imaging system for musculoskeletal tissues
-
Huang Q.H., Zheng Y.P., Lu M.H., and Chi Z.R. Development of a portable 3D ultrasound imaging system for musculoskeletal tissues. Ultrasonics 43 (2005) 153-163
-
(2005)
Ultrasonics
, vol.43
, pp. 153-163
-
-
Huang, Q.H.1
Zheng, Y.P.2
Lu, M.H.3
Chi, Z.R.4
-
45
-
-
0033652882
-
Mechanomyographic amplitude and mean power output during maximal, concentric, isokinetic muscle actions
-
Cramer J.T., Housh T.J., Johnson G.O., Ebersole K.T., Perry S.R., and Bull A.J. Mechanomyographic amplitude and mean power output during maximal, concentric, isokinetic muscle actions. Muscle Nerve 23 (2000) 1826-1831
-
(2000)
Muscle Nerve
, vol.23
, pp. 1826-1831
-
-
Cramer, J.T.1
Housh, T.J.2
Johnson, G.O.3
Ebersole, K.T.4
Perry, S.R.5
Bull, A.J.6
-
46
-
-
0020563131
-
Electro-myographic, peak torque, and power relationships during isokinetic movement
-
Rothstein J.M., Delitto A., Sinacore D.R., and Rose S.J. Electro-myographic, peak torque, and power relationships during isokinetic movement. Phys Ther 63 (1983) 926-933
-
(1983)
Phys Ther
, vol.63
, pp. 926-933
-
-
Rothstein, J.M.1
Delitto, A.2
Sinacore, D.R.3
Rose, S.J.4
-
47
-
-
0018883539
-
The relationship of motor-unit activation to isokinetic muscular-contraction at different contractile velocities
-
Barnes W.S. The relationship of motor-unit activation to isokinetic muscular-contraction at different contractile velocities. Phys Ther 60 (1980) 1152-1158
-
(1980)
Phys Ther
, vol.60
, pp. 1152-1158
-
-
Barnes, W.S.1
-
49
-
-
0026058102
-
A comparison of three muscle pennation assumptions and their effect on isometric and isotonic force
-
Scoh S.H., and Winter D.A. A comparison of three muscle pennation assumptions and their effect on isometric and isotonic force. J Biomech 24 (1991) 163-167
-
(1991)
J Biomech
, vol.24
, pp. 163-167
-
-
Scoh, S.H.1
Winter, D.A.2
-
50
-
-
0025029331
-
Niels Stensens geometrical theory of muscle contractions (1667): a reappraisal
-
Kardel T. Niels Stensens geometrical theory of muscle contractions (1667): a reappraisal. J Biomech 23 (1990) 953-965
-
(1990)
J Biomech
, vol.23
, pp. 953-965
-
-
Kardel, T.1
|