메뉴 건너뛰기




Volumn 22, Issue 4, 2006, Pages 394-399

Effect of Lesion Location on Fixation Strength of the Meniscal Viper Repair System: An In Vitro Study Using Porcine Menisci

Author keywords

All inside suture techniques; Biomechanics; Bucket handle tear; Meniscus fixation

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; CONTROLLED STUDY; DEVICE; IN VITRO STUDY; KNEE MENISCUS RUPTURE; NONHUMAN; RIGIDITY; STATISTICAL SIGNIFICANCE; STRENGTH; SWINE;

EID: 33645890267     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2005.12.014     Document Type: Article
Times cited : (12)

References (13)
  • 1
    • 0022486674 scopus 로고
    • Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee. A preliminary report
    • Baratz M.E., Fu F.H., and Mengato R. Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee. A preliminary report. Am J Sports Med 14 (1986) 270-275
    • (1986) Am J Sports Med , vol.14 , pp. 270-275
    • Baratz, M.E.1    Fu, F.H.2    Mengato, R.3
  • 2
    • 0036733745 scopus 로고    scopus 로고
    • Rate of knee cartilage loss after partial meniscectomy
    • Cicuttini F.M., Forbes A., and Yuanyuan W. Rate of knee cartilage loss after partial meniscectomy. J Rheumatol 29 (2002) 1954-1956
    • (2002) J Rheumatol , vol.29 , pp. 1954-1956
    • Cicuttini, F.M.1    Forbes, A.2    Yuanyuan, W.3
  • 3
    • 0027291627 scopus 로고
    • In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy
    • Ihn J.C., Kim S.J., and Park I.H. In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy. Int Orthop 17 (1993) 214-218
    • (1993) Int Orthop , vol.17 , pp. 214-218
    • Ihn, J.C.1    Kim, S.J.2    Park, I.H.3
  • 4
    • 28344455285 scopus 로고    scopus 로고
    • Biomechanical evaluation of meniscal repair systems. Comparison between Meniscal Viper Repair System™, vertical mattress FasT-Fix™ and vertical mattress Ethibond sutures
    • Chang H.C., Nyland J., Caborn D., and Burden R. Biomechanical evaluation of meniscal repair systems. Comparison between Meniscal Viper Repair System™, vertical mattress FasT-Fix™ and vertical mattress Ethibond sutures. Am J Sports Med 33 (2005) 1846-1852
    • (2005) Am J Sports Med , vol.33 , pp. 1846-1852
    • Chang, H.C.1    Nyland, J.2    Caborn, D.3    Burden, R.4
  • 5
    • 0033817326 scopus 로고    scopus 로고
    • Meniscal repair devices
    • Barber F.A., and Herbert M.A. Meniscal repair devices. Arthroscopy 16 (2000) 613-618
    • (2000) Arthroscopy , vol.16 , pp. 613-618
    • Barber, F.A.1    Herbert, M.A.2
  • 6
    • 0346059669 scopus 로고    scopus 로고
    • Load to failure testing of new meniscal repair devices
    • Barber F.A., Herbert M.A., and Richards D.P. Load to failure testing of new meniscal repair devices. Arthroscopy 20 (2004) 45-50
    • (2004) Arthroscopy , vol.20 , pp. 45-50
    • Barber, F.A.1    Herbert, M.A.2    Richards, D.P.3
  • 7
    • 0034235209 scopus 로고    scopus 로고
    • Cyclic testing of meniscal sutures
    • Seil R., Rupp S., and Kohn D.M. Cyclic testing of meniscal sutures. Arthroscopy 16 (2000) 505-510
    • (2000) Arthroscopy , vol.16 , pp. 505-510
    • Seil, R.1    Rupp, S.2    Kohn, D.M.3
  • 8
    • 0032851819 scopus 로고    scopus 로고
    • Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture
    • Song E.K., and Lee K.B. Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture. Arthroscopy 15 (1999) 726-732
    • (1999) Arthroscopy , vol.15 , pp. 726-732
    • Song, E.K.1    Lee, K.B.2
  • 9
    • 0021803978 scopus 로고
    • Collagen orientations in the meniscus of the knee joint
    • Aspden R.M., Yarker Y.E., and Hukins D.W. Collagen orientations in the meniscus of the knee joint. J Anat 140 (1985) 371-380
    • (1985) J Anat , vol.140 , pp. 371-380
    • Aspden, R.M.1    Yarker, Y.E.2    Hukins, D.W.3
  • 10
    • 0024807219 scopus 로고
    • Meniscus suture techniques. A comparative biomechanical cadaver study
    • Kohn D., and Siebert W. Meniscus suture techniques. A comparative biomechanical cadaver study. Arthroscopy 5 (1989) 324-327
    • (1989) Arthroscopy , vol.5 , pp. 324-327
    • Kohn, D.1    Siebert, W.2
  • 11
    • 33645878523 scopus 로고    scopus 로고
    • FiberWire Promotional Brochure. Arthrex Inc, 2005. Available at www.arthrex.com.
  • 12
    • 2442511176 scopus 로고    scopus 로고
    • Arthroscopic knots. Determining the optimal balance of loop security and knot security
    • Lo I.K., Burkhart S.S., Chan K.C., and Athanasiou K. Arthroscopic knots. Determining the optimal balance of loop security and knot security. Arthroscopy 20 (2004) 489-502
    • (2004) Arthroscopy , vol.20 , pp. 489-502
    • Lo, I.K.1    Burkhart, S.S.2    Chan, K.C.3    Athanasiou, K.4
  • 13
    • 11044224948 scopus 로고    scopus 로고
    • Intraspecies and interspecies comparison of the compressive properties of the medial meniscus
    • Sweigart M.A., Zhu C.F., and Burt D.M. Intraspecies and interspecies comparison of the compressive properties of the medial meniscus. Ann Biomed Eng 32 (2004) 1569-1579
    • (2004) Ann Biomed Eng , vol.32 , pp. 1569-1579
    • Sweigart, M.A.1    Zhu, C.F.2    Burt, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.