메뉴 건너뛰기




Volumn 33, Issue 12, 2005, Pages 1846-1852

Biomechanical evaluation of meniscal repair systems: A comparison of the meniscal viper repair system, the vertical mattress FasT-Fix device, and vertical mattress ethibond sutures

Author keywords

Biodegradable implants; Biomechanics; Bucket handle tear; Meniscal fixation techniques

Indexed keywords

ANALYSIS OF VARIANCE; ANIMAL TISSUE; ARTICLE; BIODEGRADABLE IMPLANT; BIOMECHANICS; EVALUATION; INTERMETHOD COMPARISON; KNEE MENISCUS RUPTURE; KNEE SURGERY; NONHUMAN; PRIORITY JOURNAL; PROSTHESIS FIXATION; RIGIDITY; STANDARD; STRESS STRAIN RELATIONSHIP; SURGICAL EQUIPMENT; SUTURING METHOD; VERTICAL MATTRESS SUTURE; WEIGHT BEARING;

EID: 28344455285     PISSN: 03635465     EISSN: None     Source Type: Journal    
DOI: 10.1177/0363546505278254     Document Type: Article
Times cited : (56)

References (26)
  • 1
    • 0035084489 scopus 로고    scopus 로고
    • Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time: An in vitro experimental study
    • Arnoczky SP, Lavagnino M. Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time: an in vitro experimental study. Am J Sports Med. 2001;29:118-123.
    • (2001) Am J Sports Med , vol.29 , pp. 118-123
    • Arnoczky, S.P.1    Lavagnino, M.2
  • 2
    • 0021803978 scopus 로고
    • Collagen orientations in the meniscus of the knee joint
    • Aspden RM, Yarker YE, Hukins DW. Collagen orientations in the meniscus of the knee joint. J Anat. 1985;140:371-380.
    • (1985) J Anat , vol.140 , pp. 371-380
    • Aspden, R.M.1    Yarker, Y.E.2    Hukins, D.W.3
  • 3
    • 0022486674 scopus 로고
    • Meniscal tears: The effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee. A preliminary report
    • Baratz ME, Fu FH, Mengato R. Meniscal tears: the effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee. A preliminary report. Am J Sports Med. 1986;14:270-275.
    • (1986) Am J Sports Med , vol.14 , pp. 270-275
    • Baratz, M.E.1    Fu, F.H.2    Mengato, R.3
  • 5
    • 0346059669 scopus 로고    scopus 로고
    • Load to failure testing of new meniscal repair devices
    • Barber FA, Herbert MA, Richards DP. Load to failure testing of new meniscal repair devices. Arthroscopy. 2004;20:45-50.
    • (2004) Arthroscopy , vol.20 , pp. 45-50
    • Barber, F.A.1    Herbert, M.A.2    Richards, D.P.3
  • 6
    • 0036305278 scopus 로고    scopus 로고
    • Biomechanical properties under cyclic loading of seven meniscus repair techniques
    • Becker R, Starke C, Heymann M, Nebelung W. Biomechanical properties under cyclic loading of seven meniscus repair techniques. Clin Orthop Relat Res. 2002;400:236-245.
    • (2002) Clin Orthop Relat Res , vol.400 , pp. 236-245
    • Becker, R.1    Starke, C.2    Heymann, M.3    Nebelung, W.4
  • 7
    • 0038689394 scopus 로고    scopus 로고
    • Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows
    • Borden P, Nyland J, Caborn DN. Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows. Am J Sports Med. 2003;31:374-378.
    • (2003) Am J Sports Med , vol.31 , pp. 374-378
    • Borden, P.1    Nyland, J.2    Caborn, D.N.3
  • 8
    • 0036733745 scopus 로고    scopus 로고
    • Rate of knee cartilage loss after partial meniscectomy
    • Cicuttini FM, Forbes A, Yuanyuan W. Rate of knee cartilage loss after partial meniscectomy. J Rheumatol. 2002;29:1954-1956.
    • (2002) J Rheumatol , vol.29 , pp. 1954-1956
    • Cicuttini, F.M.1    Forbes, A.2    Yuanyuan, W.3
  • 9
    • 0030915957 scopus 로고    scopus 로고
    • Failure strengths of suture versus biodegradable arrow for meniscal repair: An in vitro study
    • Dervin GF, Downing KJ, Keene GC. Failure strengths of suture versus biodegradable arrow for meniscal repair: an in vitro study. Arthroscopy. 1997;13:296-300.
    • (1997) Arthroscopy , vol.13 , pp. 296-300
    • Dervin, G.F.1    Downing, K.J.2    Keene, G.C.3
  • 11
    • 0346666807 scopus 로고    scopus 로고
    • Cyclic joint loading can affect the initial stability of meniscal fixation implants
    • Durselen L, Schneider J, Galler M, Claes LE, Bauer G. Cyclic joint loading can affect the initial stability of meniscal fixation implants. Clin Biomech. 2003;18:44-49.
    • (2003) Clin Biomech , vol.18 , pp. 44-49
    • Durselen, L.1    Schneider, J.2    Galler, M.3    Claes, L.E.4    Bauer, G.5
  • 12
    • 0027291627 scopus 로고
    • In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy
    • Ihn JC, Kim SJ, Park IH. In vitro study of contact area and pressure distribution in the human knee after partial and total meniscectomy. Int Orthop. 1993;17:214-218.
    • (1993) Int Orthop , vol.17 , pp. 214-218
    • Ihn, J.C.1    Kim, S.J.2    Park, I.H.3
  • 13
    • 0000309027 scopus 로고    scopus 로고
    • Forces in medial and lateral meniscus sutures during knee extension: An in vitro study
    • Kirsch L, Kohn D, Glowik A. Forces in medial and lateral meniscus sutures during knee extension: an in vitro study. J Biomech. 1998;31:104.
    • (1998) J Biomech , vol.31 , pp. 104
    • Kirsch, L.1    Kohn, D.2    Glowik, A.3
  • 14
    • 0024807219 scopus 로고
    • Meniscus suture techniques: A comparative biomechanical cadaver study
    • Kohn D, Siebert W. Meniscus suture techniques: a comparative biomechanical cadaver study. Arthroscopy. 1989;5:324-327.
    • (1989) Arthroscopy , vol.5 , pp. 324-327
    • Kohn, D.1    Siebert, W.2
  • 17
    • 0036821539 scopus 로고    scopus 로고
    • Pitfalls associated with FasT-Fix meniscal repair
    • Miller MD, Kline AJ, Gonzales J. Pitfalls associated with FasT-Fix meniscal repair. Arthroscopy. 2002;18:939-943.
    • (2002) Arthroscopy , vol.18 , pp. 939-943
    • Miller, M.D.1    Kline, A.J.2    Gonzales, J.3
  • 18
    • 0035077855 scopus 로고    scopus 로고
    • The biomechanical interdependence between the anterior cruciate ligament replacement graft and the medial meniscus
    • Papageorgiou CD, Gil JE, Kanamori A. The biomechanical interdependence between the anterior cruciate ligament replacement graft and the medial meniscus. Am J Sports Med. 2001;29:226-231.
    • (2001) Am J Sports Med , vol.29 , pp. 226-231
    • Papageorgiou, C.D.1    Gil, J.E.2    Kanamori, A.3
  • 19
    • 0031469372 scopus 로고    scopus 로고
    • Load to failure of common meniscal repair techniques: Effects of suture technique and suture material
    • Post WR, Akers SR, Kish V. Load to failure of common meniscal repair techniques: effects of suture technique and suture material. Arthroscopy. 1997;13:731-736.
    • (1997) Arthroscopy , vol.13 , pp. 731-736
    • Post, W.R.1    Akers, S.R.2    Kish, V.3
  • 20
    • 0034976148 scopus 로고    scopus 로고
    • Effect of various suture strength factors on behavior of meniscus sutures in cyclic loading conditions
    • Seil R, Rupp S, Jurecka C. Effect of various suture strength factors on behavior of meniscus sutures in cyclic loading conditions. Unfallchirurg. 2001;104:392-398.
    • (2001) Unfallchirurg , vol.104 , pp. 392-398
    • Sell, R.1    Rupp, S.2    Jurecka, C.3
  • 21
    • 0034235209 scopus 로고    scopus 로고
    • Cyclic testing of meniscal sutures
    • Seil R, Rupp S, Kohn DM. Cyclic testing of meniscal sutures. Arthroscopy. 2000;16:505-510.
    • (2000) Arthroscopy , vol.16 , pp. 505-510
    • Seil, R.1    Rupp, S.2    Kohn, D.M.3
  • 22
    • 0032851819 scopus 로고    scopus 로고
    • Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture
    • Song EK, Lee KB. Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture. Arthroscopy. 1999;15:726-732.
    • (1999) Arthroscopy , vol.15 , pp. 726-732
    • Song, E.K.1    Lee, K.B.2
  • 23
    • 2942565288 scopus 로고    scopus 로고
    • Fibrochondrocytes and their use in tissue engineering of the meniscus
    • Ashammakhi N, Ferretti P, eds. Linnanmaa, Finland: University of Oulu
    • Sweigart MA, Aufderheide AC, Athansiou KA. Fibrochondrocytes and their use in tissue engineering of the meniscus. In: Ashammakhi N, Ferretti P, eds. Topics in Tissue Engineering. Linnanmaa, Finland: University of Oulu; 2003:1-19.
    • (2003) Topics in Tissue Engineering , pp. 1-19
    • Sweigart, M.A.1    Aufderheide, A.C.2    Athansiou, K.A.3
  • 24
    • 11044224948 scopus 로고    scopus 로고
    • Intraspecies and interspecies comparison of the compressive properties of the medial meniscus
    • Sweigart MA, Zhu CF, Burt DM, et al. Intraspecies and interspecies comparison of the compressive properties of the medial meniscus. Ann Biomed Eng. 2004;32:1569-1579.
    • (2004) Ann Biomed Eng , vol.32 , pp. 1569-1579
    • Sweigart, M.A.1    Zhu, C.F.2    Burt, D.M.3
  • 25
    • 13944258026 scopus 로고    scopus 로고
    • Cyclic testing of flexible all-inside meniscus suture anchors; biomechanical analysis
    • Zantop T, Eggers AK, Musahl V, Weimann A, Petersen W. Cyclic testing of flexible all-inside meniscus suture anchors; biomechanical analysis. Am J Sports Med. 2005;33:388-394.
    • (2005) Am J Sports Med , vol.33 , pp. 388-394
    • Zantop, T.1    Eggers, A.K.2    Musahl, V.3    Weimann, A.4    Petersen, W.5
  • 26
    • 2442684325 scopus 로고    scopus 로고
    • Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors: Biomechanical evaluation of new meniscus refixation systems
    • Zantop T, Eggers AK, Weimann A. Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors: biomechanical evaluation of new meniscus refixation systems. Am J Sports Med. 2004;32:863-869.
    • (2004) Am J Sports Med , vol.32 , pp. 863-869
    • Zantop, T.1    Eggers, A.K.2    Weimann, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.