메뉴 건너뛰기




Volumn 18, Issue 3, 2006, Pages

A novel method for deploying a stent into a highly angulated position through use of a stent strut: Application of a five-in-seven system

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; AORTA BALLOON; ARTICLE; CASE REPORT; CATHETER; CLINICAL FEATURE; CORONARY ARTERY OBSTRUCTION; DRUG ELUTING STENT; FEMALE; HEART CATHETERIZATION; HUMAN; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; TRANSLUMINAL CORONARY ANGIOPLASTY;

EID: 33645864934     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Stent restenosis study investigators
    • Fishman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent restenosis study investigators. N Engl J Med 1994;331:496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fishman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 2
    • 0036135480 scopus 로고    scopus 로고
    • A stepwise strategy for the stent treatment of bifurcation coronary lesions
    • Pan M, Leo JS, Medina A, et al. A stepwise strategy for the stent treatment of bifurcation coronary lesions. Catheter Cardiovasc Interv 2002;55:50-57.
    • (2002) Catheter Cardiovasc Interv , vol.55 , pp. 50-57
    • Pan, M.1    Leo, J.S.2    Medina, A.3
  • 3
    • 0029742010 scopus 로고    scopus 로고
    • Coronary "Y" stenting: A technique for angioplasty of bifurcation stenoses
    • Fort S, Lazar C, Schwartz L. Coronary "Y" stenting: A technique for angioplasty of bifurcation stenoses. Can J Cardiol 1996;12:678-682.
    • (1996) Can J Cardiol , vol.12 , pp. 678-682
    • Fort, S.1    Lazar, C.2    Schwartz, L.3
  • 4
    • 0031938383 scopus 로고    scopus 로고
    • Modified "T" stenting: A technique for angioplasty of bifurcation coronary lesions
    • Kobayashi Y, Colombo A, Akiyama T, et al. Modified "T" stenting: A technique for angioplasty of bifurcation coronary lesions. Cathet Cardiovascular Diagn 1998;43:323-326.
    • (1998) Cathet Cardiovascular Diagn , vol.43 , pp. 323-326
    • Kobayashi, Y.1    Colombo, A.2    Akiyama, T.3
  • 5
    • 10744225662 scopus 로고    scopus 로고
    • Modified T-stenting technique with crushing for bifurcation lesions: Immediate results and 30-day outcome
    • Colombo A, Stank VG, Oleic D, et al. Modified T-stenting technique with crushing for bifurcation lesions: Immediate results and 30-day outcome. Catheter Cardiovasc Interv 2003;60:145-151.
    • (2003) Catheter Cardiovasc Interv , vol.60 , pp. 145-151
    • Colombo, A.1    Stank, V.G.2    Oleic, D.3
  • 6
    • 0032532404 scopus 로고    scopus 로고
    • Placement of coronary stents in bifurcation lesions by the "culotte" technique
    • Chevalier B, GATT B, Royer T, Guymon P. Placement of coronary stents in bifurcation lesions by the "culotte" technique. Am J Cardiol 1998;82:943-949.
    • (1998) Am J Cardiol , vol.82 , pp. 943-949
    • Chevalier, B.1    Gatt, B.2    Royer, T.3    Guymon, P.4
  • 7
    • 0030048486 scopus 로고    scopus 로고
    • "T"-shaped stent placement: A technique for the treatment of dissected bifurcation lesions
    • Carrie D, Karouny E, Chouairi S, Puel J. "T"-shaped stent placement: A technique for the treatment of dissected bifurcation lesions. Cathet Cardiovasc Diagn 1996;37:311-313.
    • (1996) Cathet Cardiovasc Diagn , vol.37 , pp. 311-313
    • Carrie, D.1    Karouny, E.2    Chouairi, S.3    Puel, J.4
  • 8
    • 0030938734 scopus 로고    scopus 로고
    • Trouser-like stenting: A new technique for bifurcation lesions
    • Khoja A, Ozbek C, Bay W, Heisel A. Trouser-like stenting: A new technique for bifurcation lesions. Cathet Cardiovasc Diagn 1997;41:192-196.
    • (1997) Cathet Cardiovasc Diagn , vol.41 , pp. 192-196
    • Khoja, A.1    Ozbek, C.2    Bay, W.3    Heisel, A.4
  • 10
    • 0343819943 scopus 로고    scopus 로고
    • Stenting of bifurcation lesions: Classification, treatment, and results
    • Lufevre T, Louvard Y, Morice MC, et al. Stenting of bifurcation lesions: Classification, treatment, and results. Catheter Cardiovasc Interv 2000;49:274-283.
    • (2000) Catheter Cardiovasc Interv , vol.49 , pp. 274-283
    • Lufevre, T.1    Louvard, Y.2    Morice, M.C.3
  • 11
    • 12144290882 scopus 로고    scopus 로고
    • Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions
    • Colombo A, Moses JW, Morice MC, et al. Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions. Circulation 2004;109:1244-1249.
    • (2004) Circulation , vol.109 , pp. 1244-1249
    • Colombo, A.1    Moses, J.W.2    Morice, M.C.3
  • 12
    • 0042165854 scopus 로고    scopus 로고
    • New technique for superior guiding catheter support during advancement of a balloon in coronary angioplasty: The anchor technique
    • Fujita S, Tamai H, Kyo E, et al. New technique for superior guiding catheter support during advancement of a balloon in coronary angioplasty: The anchor technique. Catheter Cardiovasc Interv 2003;59:482-488.
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 482-488
    • Fujita, S.1    Tamai, H.2    Kyo, E.3
  • 13
    • 0032756643 scopus 로고    scopus 로고
    • Successful stent delivery with deep seating of 6 French guiding catheters in difficult coronary anatomy
    • Bartorelli AL, Lavarra F, Trabattoni D, et al. Successful stent delivery with deep seating of 6 French guiding catheters in difficult coronary anatomy. Catheter Cardiovasc Interv 1999;48:279-284.
    • (1999) Catheter Cardiovasc Interv , vol.48 , pp. 279-284
    • Bartorelli, A.L.1    Lavarra, F.2    Trabattoni, D.3
  • 14
    • 9644276998 scopus 로고    scopus 로고
    • New method to increase a backup support of a 6 French guiding coronary catheter
    • Takahashi S, Saito S, Tanaka S, et al. New method to increase a backup support of a 6 French guiding coronary catheter. Catheter Cardiovasc Interv 2004;63:452-456.
    • (2004) Catheter Cardiovasc Interv , vol.63 , pp. 452-456
    • Takahashi, S.1    Saito, S.2    Tanaka, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.