메뉴 건너뛰기




Volumn 1, Issue , 2005, Pages 337-341

Radiated immunity tests: Reverberation chamber vs. anechoic chamber results

Author keywords

Field to line coupling; Immunity test methods; Reverberation chamber

Indexed keywords

CAPACITANCE MEASUREMENT; ELECTRIC CURRENTS; ELECTRIC LINES; ELECTRIC RESISTANCE MEASUREMENT; INSTRUMENT TESTING; REVERBERATION;

EID: 33645831561     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (9)

References (9)
  • 2
    • 0010635743 scopus 로고    scopus 로고
    • Electromagnetic compatibility (EMC)- Part 4: Testing and Measurement techniques. Section 21: Reverberation Chamber Test Methods
    • IEC 61000-4-21
    • IEC 61000-4-21, "Electromagnetic compatibility (EMC)- Part 4: Testing and Measurement techniques. Section 21: Reverberation Chamber Test Methods".
  • 4
    • 0035786020 scopus 로고    scopus 로고
    • Emission and immunity standards: Replacing field-at-a-distance measurements with total-radiated-power measurements
    • Montreal, Canada, Aug. 13-17
    • P.Wilson, G. Koepke, J. Ladbury, C. L. Holloway, "Emission and immunity standards: Replacing field-at-a-distance measurements with total-radiated-power measurements", Int. IEEE Int. Symp. Electromagnetic Compatibility, Montreal, Canada, Aug. 13-17, 2001, pp. 964-969.
    • (2001) Int. IEEE Int. Symp. Electromagnetic Compatibility , pp. 964-969
    • Wilson, P.1    Koepke, G.2    Ladbury, J.3    Holloway, C.L.4
  • 5
    • 33746355836 scopus 로고    scopus 로고
    • Impact of Equipment Response Characteristics on Anechoic and Reverberation Chamber Test Results
    • Sorrento, Italy, September 9-13
    • G. J. Freyer, M. Bäckström, "Impact of Equipment Response Characteristics on Anechoic and Reverberation Chamber Test Results", in Proceedings of EMC Europe 2002 Int. Symp. on EMC, Sorrento, Italy, September 9-13, 2002.
    • (2002) Proceedings of EMC Europe 2002 Int. Symp. on EMC
    • Freyer, G.J.1    Bäckström, M.2
  • 6
    • 33645831965 scopus 로고    scopus 로고
    • Experimental activity in using a reverberation chamber for emission and shielding effectiveness measurements: Comparison with traditional deterministic methods
    • September 6-10, Eindhoven, The Netherlands, pp
    • D. Appicciutoli, G. Buoncompagni, V. Mariani Primiani, "Experimental activity in using a reverberation chamber for emission and shielding effectiveness measurements: comparison with traditional deterministic methods", Proceedings of the Int. Symp. On Electromagnetic Compatibility EMC Europe 2004, September 6-10, Eindhoven, The Netherlands, pp. 717-722.
    • (2004) Proceedings of the Int. Symp. On Electromagnetic Compatibility EMC Europe , pp. 717-722
    • Appicciutoli, D.1    Buoncompagni, G.2    Mariani Primiani, V.3
  • 7
    • 0141974791 scopus 로고    scopus 로고
    • Radiated Immunity Testing of a Device with an External Wire: Repeatability of Reverberation Chamber Results and Correlation with Anechoic Chamber Results
    • V. Berat, F. Canavero, B. Demoulin, L. Musso, "Radiated Immunity Testing of a Device with an External Wire: Repeatability of Reverberation Chamber Results and Correlation with Anechoic Chamber Results", Proceedings of the IEEE International Symposium on EMC, 2003, pp.828-833.
    • (2003) Proceedings of the IEEE International Symposium on EMC , pp. 828-833
    • Berat, V.1    Canavero, F.2    Demoulin, B.3    Musso, L.4
  • 8
    • 0036464638 scopus 로고    scopus 로고
    • Microwave Field-to-Wire Coupling Measurements in Anechoic and Reverberation Chambers
    • Feb
    • S. Silfverskiöld,M. Bäckström, and J. Lorén, "Microwave Field-to-Wire Coupling Measurements in Anechoic and Reverberation Chambers", IEEE Trans. On EMC, VOL. 44, NO. 1, Feb. 2002, pp. 222-232.
    • (2002) IEEE Trans. On EMC , vol.44 , Issue.1 , pp. 222-232
    • Silfverskiöld, S.1    Bäckström, M.2    Lorén, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.