메뉴 건너뛰기




Volumn 23, Issue 1, 2006, Pages 45-49

Angiographic catheter reuse at the Hemodynamic Department of a public hospital in Chile;Reutilización de catéteres de angiografía en una Unidad de Hemodinamia de un hospital del sector público-Chile

Author keywords

Angiographic catheter; Angiography; Non systemic infections; Pyrogenic reactions; Reuse; Temporary bacteremia

Indexed keywords

ANGIOCARDIOGRAPHY; ARTICLE; CHILE; COHORT ANALYSIS; FEMALE; HEART CATHETERIZATION; HUMAN; INSTRUMENTATION; MALE; MIDDLE AGED; PROSPECTIVE STUDY; PUBLIC HOSPITAL; RECYCLING; STATISTICS; TIME;

EID: 33645824099     PISSN: 07161018     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (17)
  • 2
    • 0025689380 scopus 로고
    • Effects of re-use on the physical characteristics of angiographic catheters
    • Abstract PMID: 2283675 (PubMed- indexed for MEDLINE)
    • Bentolila P, Jacob R, Roberge F. Effects of re-use on the physical characteristics of angiographic catheters. J Med Eng Technol 1990; 14: 254-9, Abstract PMID: 2283675 (PubMed- indexed for MEDLINE).
    • (1990) J Med Eng Technol , vol.14 , pp. 254-259
    • Bentolila, P.1    Jacob, R.2    Roberge, F.3
  • 3
    • 0036857938 scopus 로고    scopus 로고
    • Development of a program model to evaluate the potencial for reuse single-use medical devices: Results of a pilot test study
    • Abreu E L, Haire D M, Malchesky P S, Wolf-Bloom D F, Cornhill J F. Development of a program model to evaluate the potencial for reuse single-use medical devices: results of a pilot test study. Biomed Instrum Technol 2002; 36: 389-404.
    • (2002) Biomed Instrum Technol , vol.36 , pp. 389-404
    • Abreu, E.L.1    Haire, D.M.2    Malchesky, P.S.3    Wolf-Bloom, D.F.4    Cornhill, J.F.5
  • 7
    • 0035290770 scopus 로고    scopus 로고
    • A randomized study of the safety and efficacy of reused angioplasty balloon catheters
    • Zubaid M, Thomas C S, Salman H, Al-Rashdan I, Hayat N, Habashi A, et al. A randomized study of the safety and efficacy of reused angioplasty balloon catheters. Indian Heart J 2001; 53: 167-71.
    • (2001) Indian Heart J , vol.53 , pp. 167-171
    • Zubaid, M.1    Thomas, C.S.2    Salman, H.3    Al-Rashdan, I.4    Hayat, N.5    Habashi, A.6
  • 8
    • 0029904401 scopus 로고    scopus 로고
    • Risks of reusing coronary angioplasty catheters: Results of an experimental study
    • Grimandi G, Sellal O, Grimaldi F, Crochet D. Risks of reusing coronary angioplasty catheters: results of an experimental study. Cathet Cardiovasc Diagn 1996; 38: 123-30; discussion 131-2.
    • (1996) Cathet Cardiovasc Diagn , vol.38 , pp. 123-130
    • Grimandi, G.1    Sellal, O.2    Grimaldi, F.3    Crochet, D.4
  • 9
    • 0004051529 scopus 로고
    • Montreal: Conseil d̈valuation des technologies de la sant, du Quebec, The reuse of single-use Medical Devices, Canadian Hospital Association
    • The reuse of single-use catheters, Montreal: Conseil d̈valuation des technologies de la sant, du Quebec, 1993. The reuse of single-use Medical Devices, Canadian Hospital Association.
    • (1993) The Reuse of Single-use Catheters
  • 10
    • 0026235324 scopus 로고
    • Reusing single-use cardiac catheters
    • Review
    • Comis J. Reusing single-use cardiac catheters. Dimens Health Serv 1991; 68: 8-9, 34-5. Review.
    • (1991) Dimens Health Serv , vol.68 , pp. 8-9
    • Comis, J.1
  • 12
    • 0032885180 scopus 로고    scopus 로고
    • Reuse of catheters for percutaneous transluminal coronary angioplasty: Effects on procedure time and clinical outcomes
    • Shaw JP, Eisenberg MJ, Azoullay A, Nguyen N. Reuse of catheters for percutaneous transluminal coronary angioplasty: effects on procedure time and clinical outcomes. Catheter Cardiovasc Interv 1999; 48: 54-60.
    • (1999) Catheter Cardiovasc Interv , vol.48 , pp. 54-60
    • Shaw, J.P.1    Eisenberg, M.J.2    Azoullay, A.3    Nguyen, N.4
  • 13
    • 0034932576 scopus 로고    scopus 로고
    • Risk of infection by reprocessed and resterilized virus-contaminated catheters; an in-vitro study
    • Luijt D S, Schirm J, Savelkoul P H, Hoekstra A. Risk of infection by reprocessed and resterilized virus-contaminated catheters; an in-vitro study. Eur Heart J 2001; 22: 378-84.
    • (2001) Eur Heart J , vol.22 , pp. 378-384
    • Luijt, D.S.1    Schirm, J.2    Savelkoul, P.H.3    Hoekstra, A.4
  • 16
    • 84858571122 scopus 로고    scopus 로고
    • Pirogenia em cateterismo cardíaco: Deteccao da causa e erradicacao, pela padronizacao do reprocesamiento de materiais
    • Belho Horizonte
    • Ajeka S, Malamam A, Da Silva P A. Pirogenia em cateterismo cardíaco: Deteccao da causa e erradicacao, pela padronizacao do reprocesamiento de materiais, Temas Livres Enfermagen, 201, Belho Horizonte, 2002.
    • (2002) Temas Livres Enfermagen , vol.201
    • Ajeka, S.1    Malamam, A.2    Da Silva, P.A.3
  • 17
    • 0038300481 scopus 로고    scopus 로고
    • Procedural complications following diagnostic coronary angiography are related to the operator̈s experience and the catheter size
    • Ammann P, Brunner-La Rocca H P, Anghern W, Roelli H, Sagmeister M. Procedural complications following diagnostic coronary angiography are related to the operator̈s experience and the catheter size. Catheter Cardiovasc Interv 2003; 59: 13-8.
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 13-18
    • Ammann, P.1    Brunner-La Rocca, H.P.2    Anghern, W.3    Roelli, H.4    Sagmeister, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.