메뉴 건너뛰기




Volumn 53, Issue 2, 2001, Pages 167-171

A randomized study of the safety and efficacy of reused angioplasty balloon catheters

Author keywords

Angioplasty; Coronary disease; Reused balloons

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORONARY ARTERY DISEASE; DOUBLE BLIND PROCEDURE; EQUIPMENT; FEMALE; FOLLOW UP; HUMAN; INDIA; INSTRUMENTATION; MALE; METHODOLOGY; MIDDLE AGED; PROBABILITY; RANDOMIZED CONTROLLED TRIAL; RECYCLING; REFERENCE VALUE; TRANSLUMINAL CORONARY ANGIOPLASTY; TREATMENT OUTCOME;

EID: 0035290770     PISSN: 00194832     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (17)
  • 1
    • 0031137428 scopus 로고    scopus 로고
    • Reuse of disposables in the catheterization laboratory. Report of the committee appointed by the Cardiological Society of India
    • Reuse of disposables in the catheterization laboratory. Report of the committee appointed by the Cardiological Society of India. Indian Heart J 1997; 49: 329-331
    • (1997) Indian Heart J , vol.49 , pp. 329-331
  • 2
    • 0029946431 scopus 로고    scopus 로고
    • Re-use of electrode catheters labelled as single use for clinical cardiac electrophysiological studies
    • Ross DL. Re-use of electrode catheters labelled as single use for clinical cardiac electrophysiological studies. Aust NZ J Med 1996; 26: 632-635
    • (1996) Aust NZ J Med , vol.26 , pp. 632-635
    • Ross, D.L.1
  • 4
    • 0028126732 scopus 로고
    • Reuse of balloon catheters for coronary angioplasty: A potential cost saving strategy
    • Plante S, Strauss BH, Goulet G, Watson RK, Chisholm RJ. Reuse of balloon catheters for coronary angioplasty: a potential cost saving strategy. J Am Coll Cardiol 1994; 24: 1475-1481
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1475-1481
    • Plante, S.1    Strauss, B.H.2    Goulet, G.3    Watson, R.K.4    Chisholm, R.J.5
  • 7
    • 0025542168 scopus 로고
    • Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Implications for patient selection
    • Ellis SG, Vandormael MG, Cowley MJ, DiSciascio G, Deligonul U, Topol EJ, et al. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel coronary disease. Implications for patient selection. Circulation 1990; 82: 1193-1202
    • (1990) Circulation , vol.82 , pp. 1193-1202
    • Ellis, S.G.1    Vandormael, M.G.2    Cowley, M.J.3    Disciascio, G.4    Deligonul, U.5    Topol, E.J.6
  • 8
    • 0022501175 scopus 로고
    • CDC guideline for handwashing and hospital environmental control, 1985
    • Garner JS, Favero MS. CDC guideline for handwashing and hospital environmental control, 1985. Infect Control 1986; 7: 231-243
    • (1986) Infect Control , vol.7 , pp. 231-243
    • Garner, J.S.1    Favero, M.S.2
  • 10
    • 84944284858 scopus 로고
    • Stability and inactivation of HTLV-III/LAV under clinical and laboratory environments
    • Resnick L, Veren K, Salahuddin SZ, Tondreau S, Markham PD. Stability and inactivation of HTLV-III/LAV under clinical and laboratory environments. JAMA 1986; 255: 1887-1891
    • (1986) JAMA , vol.255 , pp. 1887-1891
    • Resnick, L.1    Veren, K.2    Salahuddin, S.Z.3    Tondreau, S.4    Markham, P.D.5
  • 11
    • 0029914903 scopus 로고    scopus 로고
    • Reuse of single-use medical devices: Who makes the decision?
    • Woollard K. Reuse of single-use medical devices: who makes the decision? Medical J Aust 1996; 164: 538
    • (1996) Medical J Aust , vol.164 , pp. 538
    • Woollard, K.1
  • 12
    • 0033427966 scopus 로고    scopus 로고
    • Reuse of angioplasty catheters and risk of Creutzfeldt-Jakob disease
    • Fagih B, Eisenberg MJ. Reuse of angioplasty catheters and risk of Creutzfeldt-Jakob disease. Am Heart J 1999; 137: 1173-1178
    • (1999) Am Heart J , vol.137 , pp. 1173-1178
    • Fagih, B.1    Eisenberg, M.J.2
  • 14
    • 0029904401 scopus 로고    scopus 로고
    • Risks of reusing coronary angioplasty catheters: Results of an experimental study
    • Grimandi G, Sellal O, Grimandi F, Crochet D. Risks of reusing coronary angioplasty catheters: results of an experimental study. Cathet Cardiovasc Diagn 1996; 38: 123-130
    • (1996) Cathet Cardiovasc Diagn , vol.38 , pp. 123-130
    • Grimandi, G.1    Sellal, O.2    Grimandi, F.3    Crochet, D.4
  • 15
  • 16
    • 0020631756 scopus 로고
    • Fever, chills, and hypotension following cadiac catheterization with single-and multiple-use disposable catheters
    • Jacobson JA, Schwartz CE, Marshall HW, Conti M, Burke JP. Fever, chills, and hypotension following cadiac catheterization with single-and multiple-use disposable catheters. Cathet Cardiovasc Diagn 1983; 9: 39-46
    • (1983) Cathet Cardiovasc Diagn , vol.9 , pp. 39-46
    • Jacobson, J.A.1    Schwartz, C.E.2    Marshall, H.W.3    Conti, M.4    Burke, J.P.5
  • 17
    • 0010984062 scopus 로고    scopus 로고
    • Reuse of coronary angioplasty catheters
    • Feldman T. Reuse of coronary angioplasty catheters. Cathet Cardiovasc Diagn 1996; 38: 131-132
    • (1996) Cathet Cardiovasc Diagn , vol.38 , pp. 131-132
    • Feldman, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.