메뉴 건너뛰기




Volumn 27, Issue 2, 2006, Pages 363-369

Blood-flow volume quantification in internal carotid and vertebral arteries: Comparison of 3 different ultrasound techniques with phase-contrast MR imaging

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERY BLOOD FLOW; ARTICLE; B SCAN; BRAIN BLOOD FLOW; COLOR ULTRASOUND FLOWMETRY; CORRELATION ANALYSIS; DIAGNOSTIC IMAGING; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; INTERNAL CAROTID ARTERY; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHASE CONTRAST MICROSCOPY; QUANTITATIVE ANALYSIS; RELIABILITY; RHEOENCEPHALOGRAPHY; STATISTICAL SIGNIFICANCE; VERTEBRAL ARTERY; BLOOD FLOW VELOCITY; BLOOD VOLUME; COMPARATIVE STUDY; ECHOENCEPHALOGRAPHY; IMAGE ENHANCEMENT; IMAGE PROCESSING; MAGNETIC RESONANCE ANGIOGRAPHY; MATHEMATICAL COMPUTING; METHODOLOGY; MIDDLE AGED; PHYSIOLOGY; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY;

EID: 33645751359     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (115)

References (30)
  • 1
    • 0026035484 scopus 로고
    • Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings
    • Wada T, Kodaira K, Fujishiro K, et al. Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings. Stroke 1991;33:319-23
    • (1991) Stroke , vol.33 , pp. 319-323
    • Wada, T.1    Kodaira, K.2    Fujishiro, K.3
  • 3
    • 0032727350 scopus 로고    scopus 로고
    • Reference values for vertebral artery flow volume by duplex sonography in young and elderly adults
    • Seidel E, Eicke BM, Tettenborn B, et al. Reference values for vertebral artery flow volume by duplex sonography in young and elderly adults. Stroke 1999;30:2692-96
    • (1999) Stroke , vol.30 , pp. 2692-2696
    • Seidel, E.1    Eicke, B.M.2    Tettenborn, B.3
  • 4
    • 0023636204 scopus 로고
    • Quantitative evaluation of carotid blood flow before and after surgery
    • Dalla Costa F, Signorini GP, Previato Schiesari A. Quantitative evaluation of carotid blood flow before and after surgery. Int Angiol 1987;6:371-73
    • (1987) Int Angiol , vol.6 , pp. 371-373
    • Dalla Costa, F.1    Signorini, G.P.2    Previato Schiesari, A.3
  • 5
    • 0020656120 scopus 로고
    • Measurement of carotid blood flow in man and its clinical application
    • Uematsu S, Yang A, Preziosi TJ, et al. Measurement of carotid blood flow in man and its clinical application. Stroke 1983;14:256-66
    • (1983) Stroke , vol.14 , pp. 256-266
    • Uematsu, S.1    Yang, A.2    Preziosi, T.J.3
  • 6
    • 0030922875 scopus 로고    scopus 로고
    • Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: In vitro and in vivo validation
    • Lee VS, Spritzer CE, Carroll BA, et al. Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: in vitro and in vivo validation. AJR Am J Roentgenol 1997;169:1125-31
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 1125-1131
    • Lee, V.S.1    Spritzer, C.E.2    Carroll, B.A.3
  • 7
    • 0028840250 scopus 로고
    • Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation
    • Bakker CJ, Kouwenhoven M, Hartkamp MJ, et al. Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation. Magn Reson Imaging 1995;13:959-65
    • (1995) Magn Reson Imaging , vol.13 , pp. 959-965
    • Bakker, C.J.1    Kouwenhoven, M.2    Hartkamp, M.J.3
  • 8
    • 0033869743 scopus 로고    scopus 로고
    • Improved phase-contrast flow quantification by three-dimensional vessel localization
    • Zhao M, Charbel FT, Alperin N, et al. Improved phase-contrast flow quantification by three-dimensional vessel localization. Magn Reson Imaging 2000;18:687-706
    • (2000) Magn Reson Imaging , vol.18 , pp. 687-706
    • Zhao, M.1    Charbel, F.T.2    Alperin, N.3
  • 9
    • 0032470466 scopus 로고    scopus 로고
    • Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound
    • Hoppe M, Heverhagen JT, Froelich JJ, et al. Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound. Invest Radiol 1998;8:427-32
    • (1998) Invest Radiol , vol.8 , pp. 427-432
    • Hoppe, M.1    Heverhagen, J.T.2    Froelich, J.J.3
  • 10
    • 0027421999 scopus 로고
    • A comparative study of velocity measurement in major blood vessels using magnetic resonance imaging and Doppler ultrasound
    • Zananiri FV, Jackson PC, Halliwell M, et al. A comparative study of velocity measurement in major blood vessels using magnetic resonance imaging and Doppler ultrasound. Br J Radiol 1993;66:1128-33
    • (1993) Br J Radiol , vol.66 , pp. 1128-1133
    • Zananiri, F.V.1    Jackson, P.C.2    Halliwell, M.3
  • 11
    • 0042122482 scopus 로고    scopus 로고
    • Assessment of cerebral blood flow by means of blood-flow-volume measurement in the internal carotid artery: Comparative study with a 133 xenon clearance technique
    • Soustiel JF, Glenn TC, Vespa P, et al. Assessment of cerebral blood flow by means of blood-flow-volume measurement in the internal carotid artery: comparative study with a 133 xenon clearance technique. Stroke 2003;34:1876-80
    • (2003) Stroke , vol.34 , pp. 1876-1880
    • Soustiel, J.F.1    Glenn, T.C.2    Vespa, P.3
  • 12
    • 0028125804 scopus 로고
    • Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults
    • Schoning M, Walter J, Scheel P. Estimation of cerebral blood flow through color duplex sonography of the carotid and vertebral arteries in healthy adults. Stroke 1994;25:17-22
    • (1994) Stroke , vol.25 , pp. 17-22
    • Schoning, M.1    Walter, J.2    Scheel, P.3
  • 13
    • 0003094332 scopus 로고    scopus 로고
    • Ultrasonic quantification of blood flow volume
    • Tegeler CH, Babikian VL, Gomez CR, eds. New York: Mosby-Year Book
    • Eicke BM, Tegeler CH. Ultrasonic quantification of blood flow volume. In: Tegeler CH, Babikian VL, Gomez CR, eds. Neurosonology. New York: Mosby-Year Book;1996:101-10
    • (1996) Neurosonology , pp. 101-110
    • Eicke, B.M.1    Tegeler, C.H.2
  • 14
    • 0034105199 scopus 로고    scopus 로고
    • B-Flow: A new method for the detection of blood flow
    • Weskott HP. B-Flow: a new method for the detection of blood flow. Ultraschall Med 2000;21:59-65
    • (2000) Ultraschall Med , vol.21 , pp. 59-65
    • Weskott, H.P.1
  • 15
    • 0036788306 scopus 로고    scopus 로고
    • B-Flow evaluation of carotid arterial stenosis: Initial experience
    • Bucek RA, Reiter M, Koppensteiner I, et a. B-Flow evaluation of carotid arterial stenosis: initial experience. Radiology 2002;225:295-99
    • (2002) Radiology , vol.225 , pp. 295-299
    • Bucek, R.A.1    Reiter, M.2    Koppensteiner, I.3
  • 16
    • 0036176703 scopus 로고    scopus 로고
    • Blood flow volume quantification of cerebral ischemia: Comparison of three noninvasive imaging techniques of carotid and vertebral arteries
    • Ho SS, Chan YL, Yeung DK, et al. Blood flow volume quantification of cerebral ischemia: comparison of three noninvasive imaging techniques of carotid and vertebral arteries. AJR Am J Roentgenol 2002;178:551-56
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 551-556
    • Ho, S.S.1    Chan, Y.L.2    Yeung, D.K.3
  • 17
    • 0036288135 scopus 로고    scopus 로고
    • Reproducibility of total cerebral blood How measurements using phase contrast magnetic resonance imaging
    • Spilt A, Box FM, van der Geest RJ, et al. Reproducibility of total cerebral blood How measurements using phase contrast magnetic resonance imaging. J Magn Reson Imaging 2002;16:1-5
    • (2002) J Magn Reson Imaging , vol.16 , pp. 1-5
    • Spilt, A.1    Box, F.M.2    Van Der Geest, R.J.3
  • 21
    • 0034047755 scopus 로고    scopus 로고
    • The application of color power angiography to the longitudinal quantification of blood flow volume in the fetal middle cerebral arteries, ascending aorta, descending aorta, and renal arteries during gestation
    • Konje JC, Abrams K, Bell S, et al. The application of color power angiography to the longitudinal quantification of blood flow volume in the fetal middle cerebral arteries, ascending aorta, descending aorta, and renal arteries during gestation. Am J Obstet Gynecol 2000;182:393-400
    • (2000) Am J Obstet Gynecol , vol.182 , pp. 393-400
    • Konje, J.C.1    Abrams, K.2    Bell, S.3
  • 22
    • 0030044080 scopus 로고    scopus 로고
    • Cerebrovascular disease assessed by color-flow and power Doppler ultrasonography: Comparison with digital subtraction angiography in internal carotid artery stenosis
    • Griewing B, Morgenstern C, Driesner F, et al. Cerebrovascular disease assessed by color-flow and power Doppler ultrasonography: comparison with digital subtraction angiography in internal carotid artery stenosis. Stroke 1996;27:95-100
    • (1996) Stroke , vol.27 , pp. 95-100
    • Griewing, B.1    Morgenstern, C.2    Driesner, F.3
  • 23
    • 0030030191 scopus 로고    scopus 로고
    • Sonographic assessment of carotid artery stenosis: Comparison of power Doppler imaging and color Doppler flow imaging
    • Steinke W, Meairs S, Ries S, et al. Sonographic assessment of carotid artery stenosis: comparison of power Doppler imaging and color Doppler flow imaging. Stroke 1996:27:91-94
    • (1996) Stroke , vol.27 , pp. 91-94
    • Steinke, W.1    Meairs, S.2    Ries, S.3
  • 24
    • 16644377789 scopus 로고    scopus 로고
    • Combined use of color duplex ultrasonography and B-flow imaging for evaluation of patients with carotid artery stenosis
    • Tola M, Yurdakul M, Cumhur T. Combined use of color duplex ultrasonography and B-flow imaging for evaluation of patients with carotid artery stenosis. AJNR Am J Neuroradiol 2004;25:1856-60
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 1856-1860
    • Tola, M.1    Yurdakul, M.2    Cumhur, T.3
  • 25
    • 0034827704 scopus 로고    scopus 로고
    • B-mode flow imaging of the carotid artery
    • Umemura A, Yamada K. B-mode flow imaging of the carotid artery. Stroke 2001;32:2055-57
    • (2001) Stroke , vol.32 , pp. 2055-2057
    • Umemura, A.1    Yamada, K.2
  • 26
    • 0029964887 scopus 로고    scopus 로고
    • Measuring blood flow by nontriggered 2D phase-contrast MR angiography
    • Bakker CJ, Hartkamp MJ, Mali WP. Measuring blood flow by nontriggered 2D phase-contrast MR angiography. Magn Reson Imaging 1996;14:609-14
    • (1996) Magn Reson Imaging , vol.14 , pp. 609-614
    • Bakker, C.J.1    Hartkamp, M.J.2    Mali, W.P.3
  • 27
    • 0025388812 scopus 로고
    • The measurement of time-averaged flow by magnetic resonance imaging using continuous acquisition in the carotid arteries and its comparison with Doppler ultrasound
    • Tarnawski M, Padayachee S, West DJ, et al. The measurement of time-averaged flow by magnetic resonance imaging using continuous acquisition in the carotid arteries and its comparison with Doppler ultrasound. Clin Phys Physiol Meas 1990;11:27-36
    • (1990) Clin Phys Physiol Meas , vol.11 , pp. 27-36
    • Tarnawski, M.1    Padayachee, S.2    West, D.J.3
  • 28
    • 0029130430 scopus 로고
    • An experimental study of the accuracy of volume flow measurements using commercial ultrasound systems
    • Winkler AJ, Wu J, Case T, et al. An experimental study of the accuracy of volume flow measurements using commercial ultrasound systems. J Vasc Tech 1995; 19:175-80
    • (1995) J Vasc Tech , vol.19 , pp. 175-180
    • Winkler, A.J.1    Wu, J.2    Case, T.3
  • 29
    • 0034079314 scopus 로고    scopus 로고
    • Preferred technique for blood volume measurement in cerebrovascular disease
    • Ho SSY, Metreweli C. Preferred technique for blood volume measurement in cerebrovascular disease. Stroke 2000;31:1342-45
    • (2000) Stroke , vol.31 , pp. 1342-1345
    • Ho, S.S.Y.1    Metreweli, C.2
  • 30
    • 0023241572 scopus 로고
    • The physical principles of Doppler and spectral analysis
    • Burns PN. The physical principles of Doppler and spectral analysis. J Clin Ultrasound. 1987;15:567-90
    • (1987) J Clin Ultrasound , vol.15 , pp. 567-590
    • Burns, P.N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.