-
1
-
-
0028027489
-
Accurate measurement of carotid stenosis
-
Toole JF, Castaldo JE. Accurate measurement of carotid stenosis. J Neuroimaging 1994; 4:222-230.
-
(1994)
J Neuroimaging
, vol.4
, pp. 222-230
-
-
Toole, J.F.1
Castaldo, J.E.2
-
2
-
-
0025734372
-
Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis
-
North American Symptomatic Carotid Endarterectomy Trial Collaborators
-
Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators. N Engl J Med 1991; 325:445-453.
-
(1991)
N Engl J Med
, vol.325
, pp. 445-453
-
-
-
3
-
-
0032511955
-
Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis
-
North American Symptomatic Carotid Endarterectomy Trial Collaborators
-
Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators. N Engl J Med 1998; 339:1415-1425.
-
(1998)
N Engl J Med
, vol.339
, pp. 1415-1425
-
-
-
4
-
-
0028938324
-
Endarterectomy for asymptomatic carotid artery stenosis
-
Asymptomatic Carotid Atherosclerosis Study Collaborators
-
Endarterectomy for asymptomatic carotid artery stenosis. Asymptomatic Carotid Atherosclerosis Study Collaborators. JAMA 1995; 273:1421-1428.
-
(1995)
JAMA
, vol.273
, pp. 1421-1428
-
-
-
5
-
-
0033772391
-
Comparison of the ECST, CC and NASCET grading methods and ultrasound for assessing carotid stenosis
-
Staikov IN, Arnold M, Mattle HP, et al. Comparison of the ECST, CC and NASCET grading methods and ultrasound for assessing carotid stenosis. J Neurol 2000; 247:681-686.
-
(2000)
J Neurol
, vol.247
, pp. 681-686
-
-
Staikov, I.N.1
Arnold, M.2
Mattle, H.P.3
-
6
-
-
0030047247
-
Prospective evaluation of new duplex cirteria to identify 70% internal carotid artery stenosis
-
254-261; discussion
-
Hood DB, Mattos MA, Mansour A, et al. Prospective evaluation of new duplex cirteria to identify 70% internal carotid artery stenosis. J Vasc Surg 1996; 23:254-261; discussion 261-262.
-
(1996)
J Vasc Surg
, vol.23
, pp. 261-262
-
-
Hood, D.B.1
Mattos, M.A.2
Mansour, A.3
-
7
-
-
0027475543
-
Detection and quantification of carotid artery stenosis: Efficacy of various Doppler velocity parameters
-
Hunink MG, Polak JF, Barlan MM, O'Leary DH. Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters. AJR Am J Roentgenol 1993; 160:619-625.
-
(1993)
AJR Am J Roentgenol
, vol.160
, pp. 619-625
-
-
Hunink, M.G.1
Polak, J.F.2
Barlan, M.M.3
O'Leary, D.H.4
-
8
-
-
0030901977
-
The measurement of internal carotid artery stenosis: Comparison of duplex with digital subtraction angiography
-
Padayachee TS, Cox TCS, Modaresi KB, Colchester ACF, Taylor PR. The measurement of internal carotid artery stenosis: comparison of duplex with digital subtraction angiography. Eur J Vasc Endovasc Surg 1997; 13:180-185.
-
(1997)
Eur J Vasc Endovasc Surg
, vol.13
, pp. 180-185
-
-
Padayachee, T.S.1
Cox, T.C.S.2
Modaresi, K.B.3
Colchester, A.C.F.4
Taylor, P.R.5
-
9
-
-
0029653914
-
Carotid endarterectomy: Preoperative angiography is outdated
-
Bell PR. Carotid endarterectomy: preoperative angiography is outdated (letter). BMJ 1995; 310:1136.
-
(1995)
BMJ
, vol.310
, pp. 1136
-
-
Bell, P.R.1
-
10
-
-
0031825255
-
Accuracy of carotid duplex is laboratory specific and must be determined by internal audit
-
Curley PJ, Norrie L, Nocholson A, Galloway JM, Wilkinson AR. Accuracy of carotid duplex is laboratory specific and must be determined by internal audit. Eur J Vasc Endovasc Surg 1998; 15:511-514.
-
(1998)
Eur J Vasc Endovasc Surg
, vol.15
, pp. 511-514
-
-
Curley, P.J.1
Norrie, L.2
Nocholson, A.3
Galloway, J.M.4
Wilkinson, A.R.5
-
11
-
-
0029558014
-
Determination of sixty percent or greater carotid artery stenosis by duplex Doppler ultrasonography
-
697-703; discussion
-
Carpenter JP, Lexa FJ, Davis JT. Determination of sixty percent or greater carotid artery stenosis by duplex Doppler ultrasonography. J Vasc Surg 1995; 22:697-703; discussion 703-705.
-
(1995)
J Vasc Surg
, vol.22
, pp. 703-705
-
-
Carpenter, J.P.1
Lexa, F.J.2
Davis, J.T.3
-
12
-
-
0029915576
-
Determination of duplex doppler ultrasound criteria appropriate to the North American Symptomatic Carotid Endarterectomy Trial
-
Carpenter JP, Lexa FJ, Davis JT. Determination of duplex doppler ultrasound criteria appropriate to the North American Symptomatic Carotid Endarterectomy Trial. Stroke 1996; 27:695-699.
-
(1996)
Stroke
, vol.27
, pp. 695-699
-
-
Carpenter, J.P.1
Lexa, F.J.2
Davis, J.T.3
-
13
-
-
0031924773
-
Predictive ability of duplex ultrasonography for internal carotid artery stenosis of 70%-99%: A comparative study
-
Chen JC, Salvian AJ, Taylor DC, Teal PA, Marotta TR, Hsiang YN. Predictive ability of duplex ultrasonography for internal carotid artery stenosis of 70%-99%: a comparative study. Ann Vasc Surg 1998; 12:244-247.
-
(1998)
Ann Vasc Surg
, vol.12
, pp. 244-247
-
-
Chen, J.C.1
Salvian, A.J.2
Taylor, D.C.3
Teal, P.A.4
Marotta, T.R.5
Hsiang, Y.N.6
-
14
-
-
0027410697
-
Correlation of North American symptomatic carotid endarterectomy trial (NASCET) angiographic definition of 70% to 99% internal carotid artery stenosis with duplex scanning
-
152-157; discussion
-
Moneta GL, Edwards JM, Chitwood RW, et al. Correlation of North American symptomatic carotid endarterectomy trial (NASCET) angiographic definition of 70% to 99% internal carotid artery stenosis with duplex scanning. J Vasc Surg 1993; 17:152-157; discussion 157-159.
-
(1993)
J Vasc Surg
, vol.17
, pp. 157-159
-
-
Moneta, G.L.1
Edwards, J.M.2
Chitwood, R.W.3
-
15
-
-
0029950569
-
Angiography and duplex grading of internal carotid stenosis: Can we overcome the confusion?
-
Nicolaides AN, Shifrin EG, Bradbury A, et al. Angiography and duplex grading of internal carotid stenosis: can we overcome the confusion? J Endovasc Surg 1996; 3:158-165.
-
(1996)
J Endovasc Surg
, vol.3
, pp. 158-165
-
-
Nicolaides, A.N.1
Shifrin, E.G.2
Bradbury, A.3
-
16
-
-
0032984798
-
New duplex ultrasound scan criteria for managing symptomatic 50% or greater carotid stenosis
-
Winkelaar GB, Chen JC, Salvian AJ, Taylor DC, Teal PA, Hsiang YN. New duplex ultrasound scan criteria for managing symptomatic 50% or greater carotid stenosis. J Vasc Surg 1999; 29:986-994.
-
(1999)
J Vasc Surg
, vol.29
, pp. 986-994
-
-
Winkelaar, G.B.1
Chen, J.C.2
Salvian, A.J.3
Taylor, D.C.4
Teal, P.A.5
Hsiang, Y.N.6
-
17
-
-
0031009410
-
Grading carotid stenosis with ultrasound. An interlaboratory comparison
-
Alexandrov AV, Vital D, Brodie DS, Hamilton P, Grotta JC. Grading carotid stenosis with ultrasound. An interlaboratory comparison. Stroke 1997; 28:1208-1210.
-
(1997)
Stroke
, vol.28
, pp. 1208-1210
-
-
Alexandrov, A.V.1
Vital, D.2
Brodie, D.S.3
Hamilton, P.4
Grotta, J.C.5
-
19
-
-
0034105199
-
B-Flow: A new method for the detection of blood flow
-
German
-
Weskott HP. B-Flow: a new method for the detection of blood flow. Ultraschall Med 2000; 21:59-65. [German]
-
(2000)
Ultraschall Med
, vol.21
, pp. 59-65
-
-
Weskott, H.P.1
|