메뉴 건너뛰기




Volumn 119, Issue , 2006, Pages 61-66

Bootstrapped ultrasound calibration

Author keywords

Bootstrapped calibration; Tracked ultrasound; Ultrasound calibration

Indexed keywords

HEALTH CARE; LINEAR TRANSFORMATIONS; METADATA; PROBES; SENSITIVITY ANALYSIS; ULTRASONICS; VIRTUAL REALITY;

EID: 33645748977     PISSN: 09269630     EISSN: 18798365     Source Type: Book Series    
DOI: None     Document Type: Conference Paper
Times cited : (15)

References (7)
  • 1
    • 0141504143 scopus 로고    scopus 로고
    • Evaluation of ultrasound-based prostate localization for image-guided radiotherapy
    • Langen KM, Pouliot J, et al. Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 57(3):635-44.
    • Int J Radiat Oncol Biol Phys , vol.57 , Issue.3 , pp. 635-644
    • Langen, K.M.1    Pouliot, J.2
  • 2
    • 17144379599 scopus 로고    scopus 로고
    • 3D ultrasonic image feature localization based on magnetic scanhead tracking: In vitro calibration and validation
    • P. R. Detmer, G. Bashein, et al. 3D Ultrasonic Image Feature Localization based on Magnetic Scanhead Tracking: In Vitro Calibration and Validation. US in Med. Biol., 23(4):597-609, 1996.
    • (1996) US in Med. Biol. , vol.23 , Issue.4 , pp. 597-609
    • Detmer, P.R.1    Bashein, G.2
  • 3
    • 0032126026 scopus 로고    scopus 로고
    • Rapid calibration for 3-D freehand ultrasound
    • R.W. Prager, Rohling R. N., et al. Rapid Calibration for 3-D Freehand Ultrasound, US in Med. Biol., 24(6):855-869, 1998.
    • (1998) US in Med. Biol. , vol.24 , Issue.6 , pp. 855-869
    • Prager, R.W.1    Rohling, R.N.2
  • 4
    • 0034804115 scopus 로고    scopus 로고
    • A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer
    • N. Pagoulatos, D. R. Haynor, et al. A Fast Calibration Method for 3-D Tracking of Ultrasound Images Using a Spatial Localizer. US in Med.Biol., 27(9):1219-1229, 2001.
    • (2001) US in Med.Biol. , vol.27 , Issue.9 , pp. 1219-1229
    • Pagoulatos, N.1    Haynor, D.R.2
  • 6
    • 0035661105 scopus 로고    scopus 로고
    • Beam calibration without a phantom for creating a 3-D freehand ultrasound system
    • Nov.
    • Muratore DM, Galloway RL. Beam calibration without a phantom for creating a 3-D freehand ultrasound system. Ultrasound Med Biol. 2001 Nov;27(11):1557-66.
    • (2001) Ultrasound Med Biol , vol.27 , Issue.11 , pp. 1557-1566
    • Muratore, D.M.1    Galloway, R.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.