메뉴 건너뛰기




Volumn 20, Issue 4, 2006, Pages 651-655

Correlating motor performance with surgical error in laparoscopic cholecystectomy

Author keywords

Laparoscopic cholecystectomy; Motion analysis; Surgical error

Indexed keywords

ARTICLE; CHOLECYSTECTOMY; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; CORRELATION ANALYSIS; CORRELATION COEFFICIENT; ELECTROMAGNETIC FIELD; ELECTRONIC SENSOR; EVALUATION; FEASIBILITY STUDY; FORCE; HUMAN; MEASUREMENT ERROR; MEDICAL EXPERT; MOTOR PERFORMANCE; POLARIMETRY; PRIORITY JOURNAL; RESIDENCY EDUCATION; SUREGADA; SURGICAL ERROR; SURGICAL PATIENT; SURGICAL TRAINING; TORQUE; VELOCITY;

EID: 33645735156     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-005-0370-8     Document Type: Article
Times cited : (32)

References (20)
  • 1
    • 0032954138 scopus 로고    scopus 로고
    • Ergonomic problems associated with laparoscopic surgery
    • Berguer R, Forkey DL, Smith WD (1999) Ergonomic problems associated with laparoscopic surgery. Surg Endosc 13: 466-468
    • (1999) Surg Endosc , vol.13 , pp. 466-468
    • Berguer, R.1    Forkey, D.L.2    Smith, W.D.3
  • 2
    • 0036065183 scopus 로고    scopus 로고
    • The relationship between motion analysis and surgical technical assessment
    • Datta V, Chang A, Mackay S, Darzi A (2002) The relationship between motion analysis and surgical technical assessment. Am J Surg 184: 70-73
    • (2002) Am J Surg , vol.184 , pp. 70-73
    • Datta, V.1    Chang, A.2    Mackay, S.3    Darzi, A.4
  • 3
    • 0034756543 scopus 로고    scopus 로고
    • The use of electromagnetic motion tracking analysis to objectively measure open surgical skill in the laboratory-based model
    • Datta V, Mackay S, Mandalia M, Darzi A (2001) The use of electromagnetic motion tracking analysis to objectively measure open surgical skill in the laboratory-based model. J Am Coll Surg 193: 479-485
    • (2001) J Am Coll Surg , vol.193 , pp. 479-485
    • Datta, V.1    Mackay, S.2    Mandalia, M.3    Darzi, A.4
  • 5
    • 0032483947 scopus 로고    scopus 로고
    • Errors enacted during endoscopic surgery - A human reliability analysis
    • Joice P, Hanna GB, Cuschieri A (1998) Errors enacted during endoscopic surgery - a human reliability analysis. Appl Ergon 29: 409-414
    • (1998) Appl Ergon , vol.29 , pp. 409-414
    • Joice, P.1    Hanna, G.B.2    Cuschieri, A.3
  • 7
    • 0141504980 scopus 로고    scopus 로고
    • Using human reliability analysis to detect surgical error in endoscopic DCR surgery
    • Malik R, White PS, MacEwen CJ (2003) Using human reliability analysis to detect surgical error in endoscopic DCR surgery. Clin Otolaryngol 28: 456-460
    • (2003) Clin Otolaryngol , vol.28 , pp. 456-460
    • Malik, R.1    White, P.S.2    MacEwen, C.J.3
  • 9
    • 0034814473 scopus 로고    scopus 로고
    • A computer-based laparoscopic skill assessment device differentiates experienced from novice laparoscopic surgeons
    • McNatt SS, Smith CD (2001) A computer-based laparoscopic skill assessment device differentiates experienced from novice laparoscopic surgeons. Surg Endosc 15: 1085-1089
    • (2001) Surg Endosc , vol.15 , pp. 1085-1089
    • McNatt, S.S.1    Smith, C.D.2
  • 10
    • 0242351899 scopus 로고    scopus 로고
    • Objective assessment of technical skills in surgery
    • Moorthy K, Münz Y, Sarker SK, Darzi A (2003) Objective assessment of technical skills in surgery. Br Med J 327: 1032-1037
    • (2003) Br Med J , vol.327 , pp. 1032-1037
    • Moorthy, K.1    Münz, Y.2    Sarker, S.K.3    Darzi, A.4
  • 11
    • 27144470793 scopus 로고    scopus 로고
    • In vivo kinematic measurement during laparoscopic cholecystectomy
    • Rasmus M, Riener R, Reiter S, Schneider A, Feussner H (2004) In vivo kinematic measurement during laparoscopic cholecystectomy. Surg Endosc 18: 1649-1656
    • (2004) Surg Endosc , vol.18 , pp. 1649-1656
    • Rasmus, M.1    Riener, R.2    Reiter, S.3    Schneider, A.4    Feussner, H.5
  • 12
    • 0033623227 scopus 로고    scopus 로고
    • Skills evaluation in minimally invasive surgery using force/torque signatures
    • Richards C, Rosen J, Hannaford B, Pellegrini C, Sinanan M (2000) Skills evaluation in minimally invasive surgery using force/torque signatures. Surg Endosc 14: 791-798
    • (2000) Surg Endosc , vol.14 , pp. 791-798
    • Richards, C.1    Rosen, J.2    Hannaford, B.3    Pellegrini, C.4    Sinanan, M.5
  • 13
    • 0035032844 scopus 로고    scopus 로고
    • Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills
    • Rosen J, Hannaford B (2001) Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills. IEEE Trans Biomed Eng 48: 579-591
    • (2001) IEEE Trans Biomed Eng , vol.48 , pp. 579-591
    • Rosen, J.1    Hannaford, B.2
  • 15
    • 0032211748 scopus 로고    scopus 로고
    • Learning to predict human error: Issues of acceptability, reliability and validity
    • Stanton NA, Stevenage SV (1998) Learning to predict human error: issues of acceptability, reliability and validity. Ergon 41: 1737-1756
    • (1998) Ergon , vol.41 , pp. 1737-1756
    • Stanton, N.A.1    Stevenage, S.V.2
  • 16
    • 7744232787 scopus 로고    scopus 로고
    • Identification and categorization of technical errors by observational clinical human reliability assessment (OCHRA) during laparoscopic cholecystectomy
    • Tang B, Hanna GB, Joice P, Cuschieri A (2004) Identification and categorization of technical errors by observational clinical human reliability assessment (OCHRA) during laparoscopic cholecystectomy. Arch Surg 139: 1215-1220
    • (2004) Arch Surg , vol.139 , pp. 1215-1220
    • Tang, B.1    Hanna, G.B.2    Joice, P.3    Cuschieri, A.4
  • 17
    • 0032224249 scopus 로고    scopus 로고
    • Development of virtual environments for training skills and reducing errors in laparoscopic surgery
    • Tendick F, Downes M, Cavusoglu MC, Gantert W, Way LW (1998) Development of virtual environments for training skills and reducing errors in laparoscopic surgery. Proc SPIE 3262: 36-44
    • (1998) Proc SPIE , vol.3262 , pp. 36-44
    • Tendick, F.1    Downes, M.2    Cavusoglu, M.C.3    Gantert, W.4    Way, L.W.5
  • 18
    • 0003360958 scopus 로고
    • Future or laparoscopic surgery
    • Way LW, Bhoyrul S, Mori T (eds). Churchill Livingstone, New York
    • Tendick F, Mori T, Way LW (1995) Future or laparoscopic surgery. In: Way LW, Bhoyrul S, Mori T (eds). Fundamentals of laparoscopic surgery. Churchill Livingstone, New York, pp 235-252
    • (1995) Fundamentals of Laparoscopic Surgery , pp. 235-252
    • Tendick, F.1    Mori, T.2    Way, L.W.3
  • 19
    • 0002088191 scopus 로고    scopus 로고
    • A surgeon's perspective on the difficulties of laparoscopic surgery
    • Taylor RH, Lavalleé S, Burdea GC, Mösges R (eds). MIT Press, Cambridge, MA
    • Treat M (1996) A surgeon's perspective on the difficulties of laparoscopic surgery. In: Taylor RH, Lavalleé S, Burdea GC, Mösges R (eds). Computer-integrated surgery. MIT Press, Cambridge, MA, pp 559-560
    • (1996) Computer-integrated Surgery , pp. 559-560
    • Treat, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.