메뉴 건너뛰기




Volumn 18, Issue 11, 2004, Pages 1649-1656

In vivo kinematic measurement during laparoscopic cholecystectomy

Author keywords

Computer assisted surgery; In vivo measurements; Kinematic measurement; Laparoscopic surgery; Motion analysis; Robotics

Indexed keywords

ADULT; ARTICLE; CAMERA; CHOLECYSTECTOMY; COMPUTER ASSISTED SURGERY; COMPUTER PROGRAM; CONTROLLED STUDY; ELECTROMAGNETIC FIELD; ERGONOMICS; FEASIBILITY STUDY; FEMALE; GALLBLADDER; HUMAN; MALE; MATHEMATICAL ANALYSIS; MATHEMATICAL MODEL; MEDICAL DOCUMENTATION; PARAMETER; PRIORITY JOURNAL; ROBOTICS; SIMULATION; VELOCITY;

EID: 27144470793     PISSN: 09302794     EISSN: 14322218     Source Type: Journal    
DOI: 10.1007/s00464-003-9196-4     Document Type: Article
Times cited : (9)

References (11)
  • 4
    • 0034932308 scopus 로고    scopus 로고
    • Influence of handle design on the surgeon's upper limb movements, muscle recruitment, and fatigue during endoscopic suturing
    • TA Emam TG Frank GB Hanna 2001 Influence of handle design on the surgeon's upper limb movements, muscle recruitment, and fatigue during endoscopic suturing Surg Endosc 15 667 672
    • (2001) Surg Endosc , vol.15 , pp. 667-672
    • Emam, T.A.1    Frank, T.G.2    Hanna, G.B.3
  • 5
    • 0033002233 scopus 로고    scopus 로고
    • Rocker handle for endoscopic needle drivers: Technical and ergonomic evaluation by infrared motion analysis system
    • TA Emam TG Frank GB Hanna 1999 Rocker handle for endoscopic needle drivers: technical and ergonomic evaluation by infrared motion analysis system Surg Endosc 13 658 661
    • (1999) Surg Endosc , vol.13 , pp. 658-661
    • Emam, T.A.1    Frank, T.G.2    Hanna, G.B.3
  • 6
    • 0013034933 scopus 로고    scopus 로고
    • A comparison of the accuracy of an electromagnetic and a hybrid ultrasound-inertia position tracking system
    • V Kindratenko 2001 A comparison of the accuracy of an electromagnetic and a hybrid ultrasound-inertia position tracking system Presence 10 657 663
    • (2001) Presence , vol.10 , pp. 657-663
    • Kindratenko, V.1
  • 7
    • 0034954795 scopus 로고    scopus 로고
    • Hierarchical decomposition of laparoscopic surgery: A human factors approach to investigating the operating room environment
    • CL MacKenzie JA Ibbotson CGL Cao AJ Lomax 2001 Hierarchical decomposition of laparoscopic surgery: a human factors approach to investigating the operating room environment Min Invas Ther Allied Technol 10 121 127
    • (2001) Min Invas Ther Allied Technol , vol.10 , pp. 121-127
    • MacKenzie, C.L.1    Ibbotson, J.A.2    Cao, C.G.L.3    Lomax, A.J.4
  • 8
    • 6944237311 scopus 로고    scopus 로고
    • On defining metrices for assessing laparoscopic surgical skills in a virtual training environment
    • IOS Press .
    • S Payandeh AJ Lomax J Dill CL MacKenzie CG Cao 2002 On defining metrices for assessing laparoscopic surgical skills in a virtual training environment Medicine meets virtual reality IOS Press. 334 340
    • (2002) Medicine Meets Virtual Reality , pp. 334-340
    • Payandeh, S.1    Lomax, A.J.2    Dill, J.3    MacKenzie, C.L.4    Cao, C.G.5
  • 9
    • 0034850217 scopus 로고    scopus 로고
    • Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery
    • JG Person AJ Hodgson AG Nagy 2001 Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery Surg Endosc 15 997 1003
    • (2001) Surg Endosc , vol.15 , pp. 997-1003
    • Person, J.G.1    Hodgson, A.J.2    Nagy, A.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.