메뉴 건너뛰기




Volumn 26, Issue 2, 2006, Pages 149-153

Forecasting the ESDD of insulator based on least squares support vector machine

Author keywords

Equal salt deposit density forecasting; Insulator; Leakage current; Least squares support vector machine

Indexed keywords

ATMOSPHERIC HUMIDITY; COMPUTER SIMULATION; FORECASTING; LEAKAGE CURRENTS; LEAST SQUARES APPROXIMATIONS; MATHEMATICAL MODELS; MONITORING; ONLINE SYSTEMS; POLLUTION; SALT DEPOSITS; TEMPERATURE; VECTORS;

EID: 33645642398     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (25)

References (15)
  • 1
    • 85009339830 scopus 로고    scopus 로고
    • Chinese source
  • 2
    • 2542417382 scopus 로고    scopus 로고
    • Test and research on cleaning of high voltage transmission line based on salt density
    • Wang Tao, Ou Qihe, Wu Jianghong, et al. Test and research on cleaning of high voltage transmission line based on salt density[J]. Power System Technology, 2004, 28(4): 22-26.
    • (2004) Power System Technology , vol.28 , Issue.4 , pp. 22-26
    • Wang, T.1    Ou, Q.2    Wu, J.3
  • 3
    • 2542458386 scopus 로고    scopus 로고
    • Study on defining pollution classes and mapping pollution areas by saturated equal salt deposit density
    • Su Zhiyi. Study on defining pollution classes and mapping pollution areas by saturated equal salt deposit density[J]. Power System Technology, 2004, 28(8): 16-19.
    • (2004) Power System Technology , vol.28 , Issue.8 , pp. 16-19
    • Su, Z.1
  • 4
    • 23744483406 scopus 로고    scopus 로고
    • The building and application of a neural network model for forecasting the flashover voltage of the insulator in complex ambient conditions
    • Yang Qing, Sima Wenxia, Jiang Xingliang, et al. The building and application of a neural network model for forecasting the flashover voltage of the insulator in complex ambient conditions[J]. Proceedings of the CSEE, 2005, 25(13): 155-159.
    • (2005) Proceedings of the CSEE , vol.25 , Issue.13 , pp. 155-159
    • Yang, Q.1    Sima, W.2    Jiang, X.3
  • 5
    • 1442307833 scopus 로고    scopus 로고
    • Extrapolation of insulator's ESDD based on climate factor with artificial neural network
    • Zhang Han, Wen Xishan, Ding Hui. Extrapolation of insulator's ESDD based on climate factor with artificial neural network[J]. High Voltage Apparatus, 2003, 39(6): 31-32, 35.
    • (2003) High Voltage Apparatus , vol.39 , Issue.6
    • Zhang, H.1    Wen, X.2    Ding, H.3
  • 7
    • 0002343859 scopus 로고    scopus 로고
    • Introduction to statistical learning theory and support vector machines
    • Zhang Xuegong. Introduction to statistical learning theory and support vector machines[J]. Acta Automatica Sinica, 2000, 26(1): 32-41.
    • (2000) Acta Automatica Sinica , vol.26 , Issue.1 , pp. 32-41
    • Zhang, X.1
  • 8
    • 0141678325 scopus 로고    scopus 로고
    • Study of support vector machines for short-term load forecasting
    • Li Yuancheng, Fang Tingjian, Yu Erkeng. Study of support vector machines for short-term load forecasting[J]. Proceedings of the CSEE, 2003, 23(6): 55-59.
    • (2003) Proceedings of the CSEE , vol.23 , Issue.6 , pp. 55-59
    • Li, Y.1    Fang, T.2    Yu, E.3
  • 9
    • 10644240948 scopus 로고    scopus 로고
    • Ship power load forecasting using support vector machine
    • Wang Xihuai, Zhu Sifeng. Ship power load forecasting using support vector machine[J]. Proceedings of the CSEE, 2004, 24(10): 36-39.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.10 , pp. 36-39
    • Wang, X.1    Zhu, S.2
  • 10
    • 15744375797 scopus 로고    scopus 로고
    • Research on power plant boiler air preheater hot spots detection system based on LS-SVM
    • Liu Han, Li Qi, Liu Ding, et al. Research on power plant boiler air preheater hot spots detection system based on LS-SVM[J]. Proceedings of the CSEE, 2005, 25(3): 147-152.
    • (2005) Proceedings of the CSEE , vol.25 , Issue.3 , pp. 147-152
    • Liu, H.1    Li, Q.2    Liu, D.3
  • 11
    • 0037396222 scopus 로고    scopus 로고
    • Electrical behavior of contaminated distribution insulators exposed to natural wetting
    • Richard C S, Benner C L, Butler-Purry K L, et al. Electrical behavior of contaminated distribution insulators exposed to natural wetting[J]. IEEE Trans. on Power Delivery, 2003, 18(2): 551-558.
    • (2003) IEEE Trans. on Power Delivery , vol.18 , Issue.2 , pp. 551-558
    • Richard, C.S.1    Benner, C.L.2    Butler-Purry, K.L.3
  • 12
    • 85009339140 scopus 로고    scopus 로고
    • External insulation pollution classes of high-voltage electric power equipment
    • GB/T 5582-93
    • GB/T 5582-93. External insulation pollution classes of high-voltage electric power equipment[S].
  • 13
    • 14844291810 scopus 로고    scopus 로고
    • Artificial pollution tests on high-voltage insulators to be used on a.c. systems: Solid-layer method
    • GB/T 4585.2-91
    • GB/T 4585.2-91. Artificial pollution tests on high-voltage insulators to be used on a.c. systems: solid-layer method[S].
  • 15
    • 0030787228 scopus 로고    scopus 로고
    • Development of a remote insulator contamination monitoring system
    • Richards C N, Renowden J D. Development of a remote insulator contamination monitoring system[J]. IEEE Trans. on Power Delivery, 1997, 12(1): 389-397.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.1 , pp. 389-397
    • Richards, C.N.1    Renowden, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.