메뉴 건너뛰기




Volumn 51, Issue 8, 2006, Pages 2101-2111

Polymer gel dosimetry for the TG-43 dosimetric characterization of a new 125I interstitial brachytherapy seed

Author keywords

[No Author keywords available]

Indexed keywords

ANISOTROPY; DOSIMETRY; ION IMPLANTATION; IRRADIATION; MONTE CARLO METHODS; POLYMERS; THERMOLUMINESCENCE;

EID: 33645537480     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/8/010     Document Type: Article
Times cited : (19)

References (16)
  • 1
    • 18744386091 scopus 로고    scopus 로고
    • Polymer gel dosimetry using a three-dimensional MRI acquisition technique
    • Baras P et al 2002 Polymer gel dosimetry using a three-dimensional MRI acquisition technique Med. Phys. 29 2506-216
    • (2002) Med. Phys. , vol.29 , Issue.11 , pp. 2506-2216
    • Baras, P.1    Al, E.2
  • 2
    • 28044468392 scopus 로고    scopus 로고
    • An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients
    • Baras P, Seimenis I, Sandilos P, Vlachos L, Bieganski T, Georgiou E, Pantelis E, Papagiannis P and Sakelliou L 2005 An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients Med. Phys. 32 3339-45
    • (2005) Med. Phys. , vol.32 , Issue.11 , pp. 3339-3345
    • Baras, P.1    Seimenis, I.2    Sandilos, P.3    Vlachos, L.4    Bieganski, T.5    Georgiou, E.6    Pantelis, E.7    Papagiannis, P.8    Sakelliou, L.9
  • 3
    • 0033943154 scopus 로고    scopus 로고
    • Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: II. Analysis of B1-field inhomogeneity
    • De Deene Y, De Wagter C, De Neve W and Achten E 2000 Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: II. Analysis of B1-field inhomogeneity Phys. Med. Biol. 45 1825-39
    • (2000) Phys. Med. Biol. , vol.45 , Issue.7 , pp. 1825-1839
    • De Deene, Y.1    De Wagter, C.2    De Neve, W.3    Achten, E.4
  • 4
    • 0034764227 scopus 로고    scopus 로고
    • On the accuracy of monomer/polymer gel dosimetry in the proximity of a high dose rate 192Ir source
    • De Deene Y, Reynaert N and De Wagter C 2001 On the accuracy of monomer/polymer gel dosimetry in the proximity of a high dose rate 192Ir source Phys. Med. Biol. 46 2801-25
    • (2001) Phys. Med. Biol. , vol.46 , Issue.11 , pp. 2801-2825
    • De Deene, Y.1    Reynaert, N.2    De Wagter, C.3
  • 8
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group 43
    • Nath R, Anderson L, Luxton G, Weaver K A, Williamson J F and Meigooni A S 1995 Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group 43 Med. Phys. 22 209-34
    • (1995) Med. Phys. , vol.22 , Issue.2 , pp. 209-234
    • Nath, R.1    Anderson, L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 9
    • 4444310345 scopus 로고    scopus 로고
    • Polymer gel water equivalence and relative energy response with emphasis on low photon energy dosimetry in brachytherapy
    • Pantelis E, Karlis A K, Kozicki M, Papagiannis P, Sakelliou L and Rosiak J M 2004 Polymer gel water equivalence and relative energy response with emphasis on low photon energy dosimetry in brachytherapy Phys. Med. Biol. 49 3495-514
    • (2004) Phys. Med. Biol. , vol.49 , Issue.15 , pp. 3495-3514
    • Pantelis, E.1    Karlis, A.K.2    Kozicki, M.3    Papagiannis, P.4    Sakelliou, L.5    Rosiak, J.M.6
  • 11
  • 14
    • 3242717970 scopus 로고    scopus 로고
    • Dose verification in clinical IMRT prostate incidents
    • Sandilos P et al 2004 Dose verification in clinical IMRT prostate incidents Int. J. Radiat. Oncol. Biol. Phys. 59 1540-7
    • (2004) Int. J. Radiat. Oncol. Biol. Phys. , vol.59 , Issue.5 , pp. 1540-1547
    • Sandilos, P.1    Al, E.2
  • 15
    • 0034004934 scopus 로고    scopus 로고
    • 103Pd interstitial brachytherapy source
    • 103Pd interstitial brachytherapy source Med. Phys. 27 643-54
    • (2000) Med. Phys. , vol.27 , Issue.4 , pp. 643-654
    • Williamson, J.F.1
  • 16
    • 0036118006 scopus 로고    scopus 로고
    • Dosimetric characteristics of the DRAXIMAGE Model LS-1 I-125 interstitial brachytherapy source design: A Monte Carlo investigation
    • Williamson J F 2002 Dosimetric characteristics of the DRAXIMAGE Model LS-1 I-125 interstitial brachytherapy source design: a Monte Carlo investigation Med. Phys. 29 509-21
    • (2002) Med. Phys. , vol.29 , Issue.4 , pp. 509-521
    • Williamson, J.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.