메뉴 건너뛰기




Volumn 29, Issue 4, 2002, Pages 509-521

Dosimetric characteristics of the DRAXIMAGE model LS-1 I-125 interstitial brachytherapy source design: A Monte Carlo investigation

Author keywords

Dosimetry; I 125; Monte Carlo simulation; Permanent brachytherapy; Task Group 43

Indexed keywords

DOSIMETRY; GEOMETRY; NONDESTRUCTIVE EXAMINATION; ONCOLOGY; RADIOTHERAPY; RATE CONSTANTS; X RAY RADIOGRAPHY; X RAYS;

EID: 0036118006     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1452733     Document Type: Article
Times cited : (33)

References (50)
  • 1
    • 0032427802 scopus 로고    scopus 로고
    • Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources
    • (1998) Med. Phys. , vol.25 , pp. 2269-2270
    • Williamson, J.F.1
  • 2
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1
  • 3
  • 7
    • 0029891839 scopus 로고    scopus 로고
    • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy response artifacts
    • (1996) Phys. Med. Biol. , vol.41 , pp. 995-1006
    • Das, R.K.1
  • 8
    • 0025900734 scopus 로고
    • Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds
    • (1991) Med. Phys. , vol.18 , pp. 776-786
    • Williamson, J.F.1
  • 13
    • 0023514509 scopus 로고
    • Monte Carlo evaluation of kerma at a point for photon transport problems
    • (1987) Med. Phys. , vol.14 , pp. 567-576
    • Williamson, J.F.1
  • 21
    • 0029062568 scopus 로고
    • Experimental validation of Monte Carlo dosecalculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy
    • (1995) Med. Phys. , vol.22 , pp. 821-830
    • Valicenti, R.K.1
  • 24
    • 0001239625 scopus 로고
    • Wide-angle free-air chamber for calibration of low- energy brachytherapy sources
    • abstract
    • (1993) Med. Phys. , vol.20 , pp. 907
    • Loevinger, R.1
  • 27
    • 0032891406 scopus 로고    scopus 로고
    • Guidance to users of Nycomed Amersham and North American Scientific, Inc. 1-125 interstitial sources: Dosimetry and calibration changes: Recommendation of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry
    • (1999) Med. Phys. , vol.26 , pp. 570-573
    • Williamson, J.F.1
  • 34
  • 42
    • 0030816843 scopus 로고    scopus 로고
    • Dosimetric characteristics of the type 8 Ytterbium-169 interstitial brachytherapy source
    • (1997) J. Brachytherapy Int. , vol.13 , pp. 219-234
    • Das, R.K.1
  • 50
    • 85027236263 scopus 로고    scopus 로고
    • or from ftp.aip.org in the directory/epaps/. See the EPAPS homepage for more information


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.