메뉴 건너뛰기




Volumn 19, Issue 1, 2006, Pages 1-7

Imaging the airways in 2006

Author keywords

Airways; Imaging; Lung; Respiratory

Indexed keywords

CARBON 11; CONTRAST MEDIUM; FLUORINE 18; GALLIUM 67; GALLIUM 68; HELIUM; HELIUM 3; INDIUM 111; IODINE 123; IODINE 124; NEON; NEON 19; NITROGEN 13; OXYGEN 15; TECHNETIUM 99M; TRITIUM; UNCLASSIFIED DRUG; XENON; XENON 129;

EID: 33645473345     PISSN: 08942684     EISSN: None     Source Type: Journal    
DOI: 10.1089/jam.2006.19.1     Document Type: Review
Times cited : (8)

References (23)
  • 1
    • 84857486482 scopus 로고
    • The use of radioactive carbon dioxide to measure regional blood flow in the lungs of patients with pulmonary disease
    • West, J.B., C.T. Dollery, and P. Hugh-Jones. 1962. The use of radioactive carbon dioxide to measure regional blood flow in the lungs of patients with pulmonary disease. J. Clin. Invest. 11:1006.
    • (1962) J. Clin. Invest. , vol.11 , pp. 1006
    • West, J.B.1    Dollery, C.T.2    Hugh-Jones, P.3
  • 2
    • 0029873525 scopus 로고    scopus 로고
    • Simultaneous emission and transmission measurements as an adjunct to dynamic planar gamma camera studies
    • Bailey, D.L., M. Robinson, S.R. Meikle, et al. 1996. Simultaneous emission and transmission measurements as an adjunct to dynamic planar gamma camera studies. Eur. J. Nucl. Med. 23:326-331.
    • (1996) Eur. J. Nucl. Med. , vol.23 , pp. 326-331
    • Bailey, D.L.1    Robinson, M.2    Meikle, S.R.3
  • 3
    • 0024393031 scopus 로고
    • Comparison of planar and tomographic scintigraphy to measure the penetration index of inhaled aerosols
    • Phipps, P.R., I. Gonda, D.L. Bailey, et al. 1989. Comparison of planar and tomographic scintigraphy to measure the penetration index of inhaled aerosols. Am. Rev. Respir. Dis. 139:1516-1523.
    • (1989) Am. Rev. Respir. Dis. , vol.139 , pp. 1516-1523
    • Phipps, P.R.1    Gonda, I.2    Bailey, D.L.3
  • 4
    • 0036365650 scopus 로고    scopus 로고
    • Changes in lung deposition of aerosols due to hygroscopic growth: A fast SPECT study
    • Chan, H.-K., S. Eberl, L. Daviskis, et al. 2002. Changes in lung deposition of aerosols due to hygroscopic growth: a fast SPECT study. J. Aerosol. Med. 15:307-311.
    • (2002) J. Aerosol. Med. , vol.15 , pp. 307-311
    • Chan, H.-K.1    Eberl, S.2    Daviskis, L.3
  • 5
    • 0034886425 scopus 로고    scopus 로고
    • Aerosol deposition and clearance measurement: A novel technique using dynamic SPET
    • Eberl, S., H.-K. Chan, E. Daviskas, et al. 2001. Aerosol deposition and clearance measurement: a novel technique using dynamic SPET. Eur. J. Nucl. Med. 28:1365-1372.
    • (2001) Eur. J. Nucl. Med. , vol.28 , pp. 1365-1372
    • Eberl, S.1    Chan, H.-K.2    Daviskas, E.3
  • 6
    • 0008140833 scopus 로고
    • Metabolism of oxygen-15
    • Dollery, C.T., and J.B. West. 1960. Metabolism of oxygen-15. Nature 189:1121.
    • (1960) Nature , vol.189 , pp. 1121
    • Dollery, C.T.1    West, J.B.2
  • 7
    • 0022894831 scopus 로고
    • Quantitative evaluation of regional pulonary ventilation using PET and nitrogen-13 gas
    • Senda, M., K. Murata, H. Itoh, et al. 1986. Quantitative evaluation of regional pulonary ventilation using PET and nitrogen-13 gas. J Nucl. Med. 27:268-273.
    • (1986) J Nucl. Med. , vol.27 , pp. 268-273
    • Senda, M.1    Murata, K.2    Itoh, H.3
  • 8
    • 33645471308 scopus 로고    scopus 로고
    • Assessment of pulmonary function by PET
    • P.E. Valk, D.L. Bailey, D.W. Townsend, and M.N. Maisey, editors. London: Springer-Verlag
    • Schuster, D.P. 2003. Assessment of pulmonary function by PET. In: P.E. Valk, D.L. Bailey, D.W. Townsend, and M.N. Maisey, editors. Positron Emission Tomography: Basic Science & Clinical Practice. London: Springer-Verlag; p. 910.
    • (2003) Positron Emission Tomography: Basic Science & Clinical Practice , pp. 910
    • Schuster, D.P.1
  • 9
    • 0022552020 scopus 로고
    • Regional lung hematocrit in humans using positron emission tomography
    • Brudin, L.H., S.O. Valind, C.G. Rhodes, et al. 1986. Regional lung hematocrit in humans using positron emission tomography. J. Appl. Physiol. 60:1155-1163.
    • (1986) J. Appl. Physiol. , vol.60 , pp. 1155-1163
    • Brudin, L.H.1    Valind, S.O.2    Rhodes, C.G.3
  • 10
    • 0033870513 scopus 로고    scopus 로고
    • A combined PET/CT scanner for clinical oncology
    • Beyer, T., D.W. Townsend, T. Brun, et al. 2000. A combined PET/CT scanner for clinical oncology. J. Nucl. Med. 41:1369-1379.
    • (2000) J. Nucl. Med. , vol.41 , pp. 1369-1379
    • Beyer, T.1    Townsend, D.W.2    Brun, T.3
  • 11
    • 0031028413 scopus 로고    scopus 로고
    • Automated 3D registration of MR and PET brain images by multi-resolution optimisation of voxel similarity measures
    • Studholme, C., D.L.G. Hill, and D.J. Hawkes. 1997. Automated 3D registration of MR and PET brain images by multi-resolution optimisation of voxel similarity measures. Med. Phys. 24:25-35.
    • (1997) Med. Phys. , vol.24 , pp. 25-35
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3
  • 12
    • 0032762144 scopus 로고    scopus 로고
    • An overlap invariant entropy measure of 3D medical image alignment
    • Studholme, C., D.L.G. Hill, and D.J. Hawkes. 1999. An overlap invariant entropy measure of 3D medical image alignment. Patt. Recog. 32:71-86.
    • (1999) Patt. Recog. , vol.32 , pp. 71-86
    • Studholme, C.1    Hill, D.L.G.2    Hawkes, D.J.3
  • 13
    • 0033169211 scopus 로고    scopus 로고
    • Nonrigid registration using free-form deformations: Application to breast MR images
    • Rueckert, D., L.I. Sonoda, C. Hayes, et al. 1999. Nonrigid registration using free-form deformations: Application to breast MR images. IEEE Trans. Med. Imag. 18:712-721.
    • (1999) IEEE Trans. Med. Imag. , vol.18 , pp. 712-721
    • Rueckert, D.1    Sonoda, L.I.2    Hayes, C.3
  • 16
    • 0032234443 scopus 로고    scopus 로고
    • A three-component deformation model for image-guided surgery
    • Edwards, P.J., D.L.G. Hill, J.A. Little, et al. 1998. A three-component deformation model for image-guided surgery. Med. Imag. Anal. 2:355-367.
    • (1998) Med. Imag. Anal. , vol.2 , pp. 355-367
    • Edwards, P.J.1    Hill, D.L.G.2    Little, J.A.3
  • 17
    • 84925236268 scopus 로고    scopus 로고
    • Nonrigid registration: Concepts, algorithms, and applications
    • J.V. Hajnal, D.L.G. Hill, and D.J. Hawkes, editors. London: CRC Press
    • Rueckert, D. 2001. Nonrigid registration: concepts, algorithms, and applications. In: J.V. Hajnal, D.L.G. Hill, and D.J. Hawkes, editors. Medical Image Registration. London: CRC Press; p. 281-301.
    • (2001) Medical Image Registration , pp. 281-301
    • Rueckert, D.1
  • 19
    • 0021500331 scopus 로고
    • Applied potential tomography
    • Barber, D.C., and B.H. Brown. 1984. Applied potential tomography. J. Phys. [E] 17:723-733.
    • (1984) J. Phys. [E] , vol.17 , pp. 723-733
    • Barber, D.C.1    Brown, B.H.2
  • 20
    • 13344262689 scopus 로고    scopus 로고
    • Three-dimensional electrical impedance tomography
    • Metherall, P., D.C. Barber, R.H. Smallwood, et al. 1996. Three-dimensional electrical impedance tomography. Nature 380:509-512.
    • (1996) Nature , vol.380 , pp. 509-512
    • Metherall, P.1    Barber, D.C.2    Smallwood, R.H.3
  • 21
    • 0038159723 scopus 로고    scopus 로고
    • Regional ventilation by electrical impedance tomography. A comparison with ventilation scintigraphy in pigs
    • Hinz, J., P. Neumann, T. Dudykevych, et al. 2003. Regional ventilation by electrical impedance tomography. A comparison with ventilation scintigraphy in pigs. Chest 124:314-322.
    • (2003) Chest , vol.124 , pp. 314-322
    • Hinz, J.1    Neumann, P.2    Dudykevych, T.3
  • 22
    • 0035739614 scopus 로고    scopus 로고
    • Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent
    • Bayat, S., G. Le Due, L. Porra, et al. 2001. Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent. Phys. Med. Biol. 46:3287-3299.
    • (2001) Phys. Med. Biol. , vol.46 , pp. 3287-3299
    • Bayat, S.1    Le Due, G.2    Porra, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.