메뉴 건너뛰기




Volumn 30, Issue 1, 2006, Pages 31-34

Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up)

Author keywords

[No Author keywords available]

Indexed keywords

POLYETHYLENE;

EID: 33645418689     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-005-0021-7     Document Type: Article
Times cited : (9)

References (30)
  • 2
    • 0031709298 scopus 로고    scopus 로고
    • Rheumatoid Arthritis and hydroxyapatite coated hip prosthesis: Five year results
    • International ABG study group
    • Araujo CG, Gonzales FJ, Tonino A (1998) International ABG study group. Rheumatoid Arthritis and hydroxyapatite coated hip prosthesis: five year results. J Arthroplasty 6:660-667
    • (1998) J Arthroplasty , vol.6 , pp. 660-667
    • Araujo, C.G.1    Gonzales, F.J.2    Tonino, A.3
  • 3
    • 3042517840 scopus 로고    scopus 로고
    • High Osteolysis and revision rate with hydroxyapatite coated ABG hip prosthesis. 65 Hips in 56 patients followed for 6-9 years
    • Blacha J (2004) High Osteolysis and revision rate with hydroxyapatite coated ABG hip prosthesis. 65 hips in 56 patients followed for 6-9 years. Acta Orthop Scand 75(3):276-282
    • (2004) Acta Orthop Scand , vol.75 , Issue.3 , pp. 276-282
    • Blacha, J.1
  • 4
    • 0029009803 scopus 로고
    • Failure of Mecring screw-ring acetabular component in total hip arthroplasty. A 3 to 7-year follow-up study
    • Bruijn JD, Seelen RM, Feenstra RM, Hansen BE, Bernoski FP (1995) Failure of Mecring screw-ring acetabular component in total hip arthroplasty. A 3 to 7-year follow-up study. J Bone Joint Surg Am 77:760-766
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 760-766
    • Bruijn, J.D.1    Seelen, R.M.2    Feenstra, R.M.3    Hansen, B.E.4    Bernoski, F.P.5
  • 5
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20-32
    • (1976) Clin Orthop , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 6
    • 1642463514 scopus 로고    scopus 로고
    • Premature wear and Osteolysis in HA coated uncemented total hip arthroplasty
    • Duffy P, Sher JL, Partington PF (2004) Premature wear and Osteolysis in HA coated uncemented total hip arthroplasty. J Bone Joint Surg Br 86:36-38
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 36-38
    • Duffy, P.1    Sher, J.L.2    Partington, P.F.3
  • 7
    • 3042856817 scopus 로고    scopus 로고
    • Factors influencing the revision rate of Zweymuller acetabular cup
    • Effenberger H Ramsaver T, Dorn U, Imhof M (2004) Factors influencing the revision rate of Zweymuller acetabular cup. Int Orthop 28:155-158
    • (2004) Int Orthop , vol.28 , pp. 155-158
    • Effenberger, H.1    Ramsaver, T.2    Dorn, U.3    Imhof, M.4
  • 10
    • 0036178596 scopus 로고    scopus 로고
    • Medium term results of ABG total hip arthroplasty in young patients
    • Giannikas KA, Din R, Sadiq S, Dunningham TH (2002) Medium term results of ABG total hip arthroplasty in young patients. J Arthroplasty 17:184-188
    • (2002) J Arthroplasty , vol.17 , pp. 184-188
    • Giannikas, K.A.1    Din, R.2    Sadiq, S.3    Dunningham, T.H.4
  • 11
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC (1979) "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17-27
    • (1979) Clin Orthop , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 12
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures. Treatment by mould arthroplasty
    • Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures. Treatment by mould arthroplasty. J Bone Joint Surg Am 51:737-755
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 737-755
    • Harris, W.H.1
  • 13
    • 0027397479 scopus 로고
    • The porous coated anatomic total hip prosthesis inserted without cement
    • Heekin RD, Callaghan JJ, Hopkinson WJ (1993) The porous coated anatomic total hip prosthesis inserted without cement. J Bone Joint Surg Am 75:77-91
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 77-91
    • Heekin, R.D.1    Callaghan, J.J.2    Hopkinson, W.J.3
  • 14
    • 0020616988 scopus 로고
    • Arthrography after total hip arthroplasty. A modified technique used in the diagnosis of pain
    • Hendrix RW, Wixon RL, Rana NA, Rogers LF (1983) Arthrography after total hip arthroplasty. A modified technique used in the diagnosis of pain. Radiology 148:647-652
    • (1983) Radiology , vol.148 , pp. 647-652
    • Hendrix, R.W.1    Wixon, R.L.2    Rana, N.A.3    Rogers, L.F.4
  • 17
    • 0027161508 scopus 로고
    • Primary total hip reconstruction with titanium fibre coated prosthesis inserted without cement
    • Martell JM, Pierson RH 3rd, Jacobs JJ (1993) Primary total hip reconstruction with titanium fibre coated prosthesis inserted without cement. J Bone Joint Surg Am 75:554-571
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 554-571
    • Martell, J.M.1    Pierson III, R.H.2    Jacobs, J.J.3
  • 18
    • 0033637708 scopus 로고    scopus 로고
    • Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study
    • Mckellop H, Shen FW, Lu B, Campbell P, Salovey R (2000) Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg Am 82:1708-1725
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 1708-1725
    • Mckellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 19
  • 20
    • 0042923073 scopus 로고    scopus 로고
    • The ABG hydroxyapatite-coated hip prosthesis: One hundred consecutive operations with average 6-year follow-up
    • Rogers A, Kulkarni R, Downes EM (2003) The ABG hydroxyapatite-coated hip prosthesis: one hundred consecutive operations with average 6-year follow-up. J Arthroplasty 18:619-625
    • (2003) J Arthroplasty , vol.18 , pp. 619-625
    • Rogers, A.1    Kulkarni, R.2    Downes, E.M.3
  • 22
    • 0028198810 scopus 로고
    • The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis
    • Schmalzried TP, Guttmann D, Grecula M, Amstutz HC (1994) The relationship between the design, position, and articular wear of acetabular components inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg Am 76:677-688
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 677-688
    • Schmalzried, T.P.1    Guttmann, D.2    Grecula, M.3    Amstutz, H.C.4
  • 24
    • 0030972875 scopus 로고    scopus 로고
    • Measurement of polyethylene wear in cementless total hip arthroplasty
    • Shih CH, Lee PC, Chen JH (1997) Measurement of polyethylene wear in cementless total hip arthroplasty. J Bone Joint Surg Br 79:361-365
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 361-365
    • Shih, C.H.1    Lee, P.C.2    Chen, J.H.3
  • 26
    • 0031018638 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with a porous-coated acetabular component. Seven-to-ten-year results
    • Tompkins GS, Jacobs JJ, Kull LR (1997) Primary total hip arthroplasty with a porous-coated acetabular component. Seven-to-ten-year results. J Bone Joint Surg Am 79:169-176
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 169-176
    • Tompkins, G.S.1    Jacobs, J.J.2    Kull, L.R.3
  • 27
    • 12944305874 scopus 로고    scopus 로고
    • The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study
    • The International ABG Study Group
    • Tonino AJ, Rahmy AI (2000) The hydroxyapatite-ABG hip system: 5- to 7-year results from an international multicentre study. The International ABG Study Group. J Arthroplasty 15:274-282
    • (2000) J Arthroplasty , vol.15 , pp. 274-282
    • Tonino, A.J.1    Rahmy, A.I.2
  • 28
    • 3042516008 scopus 로고    scopus 로고
    • Catastrophic failure of an uncemented acetabular component due to high wear and osteolysis: An analysis of 154 omnifit prostheses with mean 6-year followup
    • Von Schewelow T, Sanzen L, Onsten I, Carlsson A (2004) Catastrophic failure of an uncemented acetabular component due to high wear and osteolysis: an analysis of 154 omnifit prostheses with mean 6-year followup. Acta Orthop Scand 75:283-294
    • (2004) Acta Orthop Scand , vol.75 , pp. 283-294
    • Von Schewelow, T.1    Sanzen, L.2    Onsten, I.3    Carlsson, A.4
  • 29
    • 0038686680 scopus 로고    scopus 로고
    • Experiences with the Plasmacup - Early stability, wear, remodelling and outcome
    • Wilkinson JM, Gordan A, Stockley I (2003) Experiences with the Plasmacup - early stability, wear, remodelling and outcome. Int Orthop 27 (Suppl 1):16-19
    • (2003) Int Orthop , vol.27 , Issue.1 SUPPL. , pp. 16-19
    • Wilkinson, J.M.1    Gordan, A.2    Stockley, I.3
  • 30
    • 0028956936 scopus 로고
    • Patterns of osteolysis around total hip components inserted with and without cement
    • Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:432-439
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 432-439
    • Zicat, B.1    Engh, C.A.2    Gokcen, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.