메뉴 건너뛰기




Volumn 28, Issue 3, 2004, Pages 155-158

Factors influencing the revision rate of Zweymueller acetabular cup

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BODY MASS; CONTROLLED STUDY; FEMALE; FEMUR HEAD; GENDER; HUMAN; KNEE PROSTHESIS; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; REOPERATION; RISK FACTOR; SURVIVAL RATE; TREATMENT FAILURE; ZWEYMUELLER ACETABULAR CUP;

EID: 3042856817     PISSN: 03412695     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00264-004-0546-1     Document Type: Article
Times cited : (12)

References (15)
  • 1
    • 0029886633 scopus 로고    scopus 로고
    • The porous-coated anatomic total hip prosthesis: Failure of the metal-backed acetabular component
    • Astion DJ, Saluan P, Stuhlberg BN, Rimanc CMN, Li S (1996) The porous-coated anatomic total hip prosthesis: failure of the metal-backed acetabular component. J Bone Joint Surg [Am] 78:755-766
    • (1996) J Bone Joint Surg [Am] , vol.78 , pp. 755-766
    • Astion, D.J.1    Saluan, P.2    Stuhlberg, B.N.3    Rimanc, C.M.N.4    Li, S.5
  • 2
    • 0036563404 scopus 로고    scopus 로고
    • Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: Results at nine to fourteen years
    • Crowther JD, Lachiewicz PF (2002) Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years. Bone Joint Surg [Am] 84:720-735
    • (2002) Bone Joint Surg [Am] , vol.84 , pp. 720-735
    • Crowther, J.D.1    Lachiewicz, P.F.2
  • 3
    • 0035032505 scopus 로고    scopus 로고
    • Survival analysis of cementless grit-blasted titanium total hip arthroplasties
    • Delaunay CP, Kapandji AI (2001) Survival analysis of cementless grit-blasted titanium total hip arthroplasties. J Bone Joint Surg [Br] 83:408-413
    • (2001) J Bone Joint Surg [Br] , vol.83 , pp. 408-413
    • Delaunay, C.P.1    Kapandji, A.I.2
  • 4
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 121:20-32
    • (1976) Clin Orthop , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 5
    • 0344927558 scopus 로고    scopus 로고
    • Assessment of polyethylene wear in total hip replacement
    • Devane PA, Horne JG (1999) Assessment of polyethylene wear in total hip replacement. Clin Orthop 369:59-72
    • (1999) Clin Orthop , vol.369 , pp. 59-72
    • Devane, P.A.1    Horne, J.G.2
  • 6
    • 0022976577 scopus 로고
    • Survivorship analysis in the evaluation of joint replacement
    • Dorey F, Amstutz HC (1986) Survivorship analysis in the evaluation of joint replacement. J Arthroplasty 1:63-69
    • (1986) J Arthroplasty , vol.1 , pp. 63-69
    • Dorey, F.1    Amstutz, H.C.2
  • 8
    • 0035231740 scopus 로고    scopus 로고
    • The effect of socket design, materials and liner thickness on the wear of the porous coated anatomic total hip replacement
    • Elfick AP, Hall RM, Pinder IM, Unsworth A (2001) The effect of socket design, materials and liner thickness on the wear of the porous coated anatomic total hip replacement. Proc Inst Mech Eng 215:447-457
    • (2001) Proc Inst Mech Eng , vol.215 , pp. 447-457
    • Elfick, A.P.1    Hall, R.M.2    Pinder, I.M.3    Unsworth, A.4
  • 9
    • 0037331012 scopus 로고    scopus 로고
    • A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: Clinical, radiographic and survivorship analyses with comparison to the literature
    • Epinette JA, Manley MT, D'Antonio JA, Edidin AA, Capello WN (2003) A 10-year minimum follow-up of hydroxyapatite-coated threaded cups: clinical, radiographic and survivorship analyses with comparison to the literature. J Arthroplasty 18:140-148
    • (2003) J Arthroplasty , vol.18 , pp. 140-148
    • Epinette, J.A.1    Manley, M.T.2    D'Antonio, J.A.3    Edidin, A.A.4    Capello, W.N.5
  • 10
    • 0037315541 scopus 로고    scopus 로고
    • Total hip arthroplasty with use of the cementless Zweymueller Alloclassic system. A ten to thirteen-year follow-up study
    • Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M (2003) Total hip arthroplasty with use of the cementless Zweymueller Alloclassic system. A ten to thirteen-year follow-up study. J Bone Joint Surg [Am] 85:296-303
    • (2003) J Bone Joint Surg [Am] , vol.85 , pp. 296-303
    • Garcia-Cimbrelo, E.1    Cruz-Pardos, A.2    Madero, R.3    Ortega-Andreu, M.4
  • 11
    • 0036512931 scopus 로고    scopus 로고
    • Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup
    • Grübl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F (2002) Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup. J Bone Joint Surg [Am] 84:425-431
    • (2002) J Bone Joint Surg [Am] , vol.84 , pp. 425-431
    • Grübl, A.1    Chiari, C.2    Gruber, M.3    Kaider, A.4    Gottsauner-Wolf, F.5
  • 12
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty-an end-result study using a new method of result evaluation
    • Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty-an end-result study using a new method of result evaluation. J Bone Joint Surg [Am] 51:737-755
    • (1969) J Bone Joint Surg [Am] , vol.51 , pp. 737-755
    • Harris, W.H.1
  • 13
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • Kaplan EL, Meier L (1958) Nonparametric estimation from incomplete observations. J Am Stat Ass 53:457-481
    • (1958) J Am Stat Ass , vol.53 , pp. 457-481
    • Kaplan, E.L.1    Meier, L.2
  • 14
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
    • Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13:520-534
    • (1998) J Arthroplasty , vol.13 , pp. 520-534
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3    Sullivan, R.J.4    Griffen, D.G.5    Sheehan, L.J.6
  • 15
    • 0029380423 scopus 로고
    • EBRA: A method to measure migration of acetabular components
    • Krismer M, Bauer R, Tschupik J, Mayrhofer P (1995) EBRA: A method to measure migration of acetabular components. J Biomechanics 28:1225-1236
    • (1995) J Biomechanics , vol.28 , pp. 1225-1236
    • Krismer, M.1    Bauer, R.2    Tschupik, J.3    Mayrhofer, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.