메뉴 건너뛰기




Volumn 54, Issue 2, 2006, Pages 61-66

Lower limits of hematocrit and mixed venous oxygen saturation ensuring sufficient cerebral oxygenation during hemodilution in rabbits

Author keywords

Cerebral oxygenation; Hematocrit; Hemodilution; Jugular venous oxygen saturation; Mixed venous oxygen saturation

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BRAIN OXYGEN CONSUMPTION; CARDIOPULMONARY BYPASS; CONTROLLED STUDY; HEMATOCRIT; HEMODILUTION; JUGULAR VEIN; NONHUMAN; OXYGEN SATURATION; OXYGEN TENSION; PRESSURE MEASUREMENT; RABBIT; SAFETY; TISSUE OXYGENATION;

EID: 33645324437     PISSN: 13444964     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02744602     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 1542348336 scopus 로고    scopus 로고
    • Critical values of hematocrit and mixed venous oxygen saturation as parameters for a safe cardiopulmonary bypass
    • Osawa H, Yoshii S, Abraham SJ, Hosaka S, Suzuki S, Ogata K, et al. Critical values of hematocrit and mixed venous oxygen saturation as parameters for a safe cardiopulmonary bypass. Jpn J Thorac Cardiovasc Surg 2004; 52: 49-56.
    • (2004) Jpn J Thorac Cardiovasc Surg , vol.52 , pp. 49-56
    • Osawa, H.1    Yoshii, S.2    Abraham, S.J.3    Hosaka, S.4    Suzuki, S.5    Ogata, K.6
  • 2
    • 0028911113 scopus 로고
    • Mixed venous oxygen saturation during cardiopulmonary bypass poorly predicts regional venous saturation
    • McDaniel LB, Zwischenberger JB, Vertrees RA, Nutt L, Uchida T, Nguyen T, et al. Mixed venous oxygen saturation during cardiopulmonary bypass poorly predicts regional venous saturation. Anesth Analg 1995; 80: 466-72.
    • (1995) Anesth Analg , vol.80 , pp. 466-472
    • McDaniel, L.B.1    Zwischenberger, J.B.2    Vertrees, R.A.3    Nutt, L.4    Uchida, T.5    Nguyen, T.6
  • 3
    • 0036207745 scopus 로고    scopus 로고
    • The relationship between mixed venous and regional venous oxygen saturation during cardiopulmonary bypass
    • Lindholm L, Hansdottir V, Lundqvist M, Jeppsson A. The relationship between mixed venous and regional venous oxygen saturation during cardiopulmonary bypass. Perfusion 2002; 17: 133-9.
    • (2002) Perfusion , vol.17 , pp. 133-139
    • Lindholm, L.1    Hansdottir, V.2    Lundqvist, M.3    Jeppsson, A.4
  • 4
    • 0027429709 scopus 로고
    • Accuracy of continuous jugular bulb venous oximetry during cardiopulmonary bypass
    • Nakajima T, Ohsumi H, Kuro M. Accuracy of continuous jugular bulb venous oximetry during cardiopulmonary bypass. Anesth Analg 1993; 77: 1111-5.
    • (1993) Anesth Analg , vol.77 , pp. 1111-1115
    • Nakajima, T.1    Ohsumi, H.2    Kuro, M.3
  • 7
    • 0027992411 scopus 로고
    • Evaluation of a 7.5 French pulmonary catheter for continuous monitoring of cerebral venous oxygen saturation
    • Olsen KS, Madsen PL, Børme T, Schmidt JF. Evaluation of a 7.5 French pulmonary catheter for continuous monitoring of cerebral venous oxygen saturation. J Neurosurg Anesthesiol 1994; 6: 233-8.
    • (1994) J Neurosurg Anesthesiol , vol.6 , pp. 233-238
    • Olsen, K.S.1    Madsen, P.L.2    Børme, T.3    Schmidt, J.F.4
  • 8
    • 0029925522 scopus 로고    scopus 로고
    • Jugular venous bulb oxyhemoglobin saturation during cardiac surgery: Accuracy and reliability using a continuous monitor
    • Trubiano P, Heyer EJ, Adams DC, McMahon DJ, Christiansen I, Rose EA, et al. Jugular venous bulb oxyhemoglobin saturation during cardiac surgery: Accuracy and reliability using a continuous monitor. Anesth Analg 1996; 82: 964-8.
    • (1996) Anesth Analg , vol.82 , pp. 964-968
    • Trubiano, P.1    Heyer, E.J.2    Adams, D.C.3    McMahon, D.J.4    Christiansen, I.5    Rose, E.A.6
  • 9
    • 33645323997 scopus 로고    scopus 로고
    • Functional near-infrared spectroscopy: Limitations and potential
    • Hoshi Y. Functional near-infrared spectroscopy: Limitations and potential (Eng abstr). J Jpn Coll Angiol 2005; 45: 61-7.
    • (2005) J Jpn Coll Angiol , vol.45 , pp. 61-67
    • Hoshi, Y.1
  • 11
    • 0028300411 scopus 로고
    • A prospective, randomized comparison of cerebral venous oxygen saturation during normothermic and hypothermic cardiopulmonary bypass
    • Cook DJ, Oliver WC Jr, Orszulak TA, Daly RC. A prospective, randomized comparison of cerebral venous oxygen saturation during normothermic and hypothermic cardiopulmonary bypass. J Thorac Cardiovasc Surg 1994; 107: 1020-9.
    • (1994) J Thorac Cardiovasc Surg , vol.107 , pp. 1020-1029
    • Cook, D.J.1    Oliver Jr., W.C.2    Orszulak, T.A.3    Daly, R.C.4
  • 14
    • 0028049641 scopus 로고
    • A critique of the intraoperative use of jugular venous bulb catheters during neurosurgical procedures
    • Matta BF, Lam AM, Mayberg TS, Shapira Y, Winn HR. A critique of the intraoperative use of jugular venous bulb catheters during neurosurgical procedures. Anesth Analg 1994; 79: 745-50.
    • (1994) Anesth Analg , vol.79 , pp. 745-750
    • Matta, B.F.1    Lam, A.M.2    Mayberg, T.S.3    Shapira, Y.4    Winn, H.R.5
  • 16
    • 0035499207 scopus 로고    scopus 로고
    • Decrease in jugular venous oxygen saturation during normothermic cardiopulmonary bypass predicts short-term postoperative neurologic dysfunction in elderly patients
    • Kadoi Y, Saito S, Goto F, Fujita N. Decrease in jugular venous oxygen saturation during normothermic cardiopulmonary bypass predicts short-term postoperative neurologic dysfunction in elderly patients. J Am Coll Cardiol 2001; 38: 1450-5.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 1450-1455
    • Kadoi, Y.1    Saito, S.2    Goto, F.3    Fujita, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.