메뉴 건너뛰기




Volumn 52, Issue 2, 2004, Pages 49-56

Critical Values of Hematocrit and Mixed Venous Oxygen Saturation as Parameters for a Safe Cardiopulmonary Bypass

Author keywords

Blood conservation; Cardiopulmonary bypass; Hematocrit; Mixed venous oxygen saturation

Indexed keywords

DEXTRAN 40; LACTIC ACID;

EID: 1542348336     PISSN: 13444964     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11748-004-0083-2     Document Type: Article
Times cited : (6)

References (24)
  • 2
    • 27044437528 scopus 로고
    • Conservation of blood during cardiovascular surgery
    • Cooley DA. Conservation of blood during cardiovascular surgery. Am J Surg 1995; 170: 53S-9S.
    • (1995) Am J Surg , vol.170
    • Cooley, D.A.1
  • 4
    • 0016201368 scopus 로고
    • Safe limits of hemodilution in cardiopulmonary bypass
    • Kawashima Y, Yamamoto Z, Manabe H. Safe limits of hemodilution in cardiopulmonary bypass. Surgery 1974; 76: 391-7.
    • (1974) Surgery , vol.76 , pp. 391-397
    • Kawashima, Y.1    Yamamoto, Z.2    Manabe, H.3
  • 5
    • 0017057113 scopus 로고
    • Critical point in progressive hemodilution with hydroxyethyl starch
    • Takaori M, Safar P. Critical point in progressive hemodilution with hydroxyethyl starch. Kawasaki Med J 1976; 2: 211-22.
    • (1976) Kawasaki Med J , vol.2 , pp. 211-222
    • Takaori, M.1    Safar, P.2
  • 6
    • 0017654141 scopus 로고
    • High-flow total body perfusion with severe hemodilution and normothermia in infants weighing less than 10 kg: Safe limits of hemodilution in cardiopulmonary bypass in infants
    • Kawamura M, Sakakibara K, Minamikawa O, Yokochi H, Kobayashi A. High-flow total body perfusion with severe hemodilution and normothermia in infants weighing less than 10 kg: Safe limits of hemodilution in cardiopulmonary bypass in infants. Jpn J Surg 1977; 7: 54-64.
    • (1977) Jpn J Surg , vol.7 , pp. 54-64
    • Kawamura, M.1    Sakakibara, K.2    Minamikawa, O.3    Yokochi, H.4    Kobayashi, A.5
  • 7
    • 0345563278 scopus 로고    scopus 로고
    • Minimum hematocrit at differing cardiopulmonary bypass temperatures in dogs
    • Cook DJ, Orszulak TA, Daly RC. Minimum hematocrit at differing cardiopulmonary bypass temperatures in dogs. Circulation 1998; 98: II-170-5.
    • (1998) Circulation , vol.98
    • Cook, D.J.1    Orszulak, T.A.2    Daly, R.C.3
  • 9
    • 0022521932 scopus 로고
    • Continuous venous oximetry in surgical patients
    • Nelson LD. Continuous venous oximetry in surgical patients. Ann Surg 1986; 203: 329-33.
    • (1986) Ann Surg , vol.203 , pp. 329-333
    • Nelson, L.D.1
  • 12
    • 0028564958 scopus 로고
    • In vitro evaluation of continuous mixed venous oxygen saturation and hematocrit monitors
    • Brown ME, Rawleigh JD, Gallagher JM. In vitro evaluation of continuous mixed venous oxygen saturation and hematocrit monitors. J Extra Corporeal Technol 1994; 26: 189-93.
    • (1994) J Extra Corporeal Technol , vol.26 , pp. 189-193
    • Brown, M.E.1    Rawleigh, J.D.2    Gallagher, J.M.3
  • 13
    • 0034264998 scopus 로고    scopus 로고
    • Whole-body oxygen consumption at different temperatures during cardiopulmonary bypass
    • Higuchi H, Yoshii S, Osawa H, Suzuki S, Samuel A, Hosaka S, et al. Whole-body oxygen consumption at different temperatures during cardiopulmonary bypass (Eng abstr). Kyobu Geka 2000; 53: 841-6.
    • (2000) Kyobu Geka , vol.53 , pp. 841-846
    • Higuchi, H.1    Yoshii, S.2    Osawa, H.3    Suzuki, S.4    Samuel, A.5    Hosaka, S.6
  • 14
    • 0025139753 scopus 로고
    • Continuous venous oximetry during cardiopulmonary bypass: Influence of temperature changes, perfusion flow, and hematocrit levels
    • Baraka A, Baroody M, Haroun S, Nawfal M, Dabbous A, Sibai A, et al. Continuous venous oximetry during cardiopulmonary bypass: Influence of temperature changes, perfusion flow, and hematocrit levels. J Cardiothorac Anesth 1990; 4: 35-8.
    • (1990) J Cardiothorac Anesth , vol.4 , pp. 35-38
    • Baraka, A.1    Baroody, M.2    Haroun, S.3    Nawfal, M.4    Dabbous, A.5    Sibai, A.6
  • 15
    • 0020053382 scopus 로고
    • Relationship of whole body oxygen consumption to perfusion flow rate during hypothermic cardiopulmonary bypass
    • Fox LS, Blackstone EH, Kirklin JW, Stewart RW, Samuelson PN. Relationship of whole body oxygen consumption to perfusion flow rate during hypothermic cardiopulmonary bypass. J Thorac Cardiovasc Surg 1982; 83: 239-48.
    • (1982) J Thorac Cardiovasc Surg , vol.83 , pp. 239-248
    • Fox, L.S.1    Blackstone, E.H.2    Kirklin, J.W.3    Stewart, R.W.4    Samuelson, P.N.5
  • 16
    • 0032611241 scopus 로고    scopus 로고
    • Impaired oxygen utilization during rapid cooling on cardiopulmonary bypass
    • Irita K, Kai Y, Takahashi S. Impaired oxygen utilization during rapid cooling on cardiopulmonary bypass. Fukuoka Acta Med 1999; 90: 14-22.
    • (1999) Fukuoka Acta Med , vol.90 , pp. 14-22
    • Irita, K.1    Kai, Y.2    Takahashi, S.3
  • 17
    • 0021070515 scopus 로고
    • Whole-body oxygen consumption during low-flow hypothermic cardiopulmonary bypass
    • Hickey RF, Hoar PF. Whole-body oxygen consumption during low-flow hypothermic cardiopulmonary bypass. J Thorac Cardiovasc Surg 1983; 86: 903-6.
    • (1983) J Thorac Cardiovasc Surg , vol.86 , pp. 903-906
    • Hickey, R.F.1    Hoar, P.F.2
  • 18
    • 1542371011 scopus 로고
    • Optimal flow rate in perfusion
    • Allen JG ed. Springfield, IL; Thomas
    • Clark LC Jr. Optimal flow rate in perfusion. In: Allen JG ed. Extracorporeal circulation. Springfield, IL; Thomas, 1958, 156.8-157.12.
    • (1958) Extracorporeal Circulation , pp. 1568-15712
    • Clark Jr., L.C.1
  • 20
    • 0028911113 scopus 로고
    • Mixed venous saturation during cardiopulmonary bypass poorly predicts regional venous oxygen saturation
    • McDaniel LB, Zwischenberger JB, Vertrees RA, Nutt L, Uchida T, Nguyen T, et al. Mixed venous saturation during cardiopulmonary bypass poorly predicts regional venous oxygen saturation. Anesth Analg 1995; 80: 466-72.
    • (1995) Anesth Analg , vol.80 , pp. 466-472
    • McDaniel, L.B.1    Zwischenberger, J.B.2    Vertrees, R.A.3    Nutt, L.4    Uchida, T.5    Nguyen, T.6
  • 22
    • 0029550093 scopus 로고
    • Cardiopulmonary bypass temperature, hematocrit, and cerebral oxygen delivery in humans
    • Cook DJ, Oliver WC Jr, Orszulak TA, Daly RC, Bryce RD. Cardiopulmonary bypass temperature, hematocrit, and cerebral oxygen delivery in humans. Ann Thorac Surg 1995; 60: 1671-7.
    • (1995) Ann Thorac Surg , vol.60 , pp. 1671-1677
    • Cook, D.J.1    Oliver Jr., W.C.2    Orszulak, T.A.3    Daly, R.C.4    Bryce, R.D.5
  • 23
    • 0343923690 scopus 로고    scopus 로고
    • Minimum hematocrit for normothermic cardiopulmonary bypass in dogs
    • Cook DJ, Orszulak TA, Daly RC, MacVeigh I. Minimum hematocrit for normothermic cardiopulmonary bypass in dogs. Circulation 1997; 96 (9 Suppl): II-200-4.
    • (1997) Circulation , vol.96 , Issue.9 SUPPL.
    • Cook, D.J.1    Orszulak, T.A.2    Daly, R.C.3    MacVeigh, I.4
  • 24
    • 0032751931 scopus 로고    scopus 로고
    • Cerebral response to hemodilution during hypothermic cardiopulmonary bypass in adults
    • Sungurtekin H, Cook DJ, Orszulak TA, Dary RC, Mullany CJ. Cerebral response to hemodilution during hypothermic cardiopulmonary bypass in adults. Anesth Analg 1999; 89: 1078-83
    • (1999) Anesth Analg , vol.89 , pp. 1078-1083
    • Sungurtekin, H.1    Cook, D.J.2    Orszulak, T.A.3    Dary, R.C.4    Mullany, C.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.