-
1
-
-
0027664734
-
Principles and application of ultrasound backscatter microscopy
-
F. S. Foster, O. J. Pavlin, G. R. Lockwood, L. K. Ryan, K. A. Harasiewicz, L. Berube, and A. M. Rauth, “Principles and application of ultrasound backscatter microscopy,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 40, pp. 608–616, 1993.
-
(1993)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.40
, pp. 608-616
-
-
Foster, F.S.1
Pavlin, O.J.2
Lockwood, G.R.3
Ryan, L.K.4
Harasiewicz, K.A.5
Berube, L.6
Rauth, A.M.7
-
2
-
-
0030291225
-
Beyond 30 MHz: Applications of high frequency ultrasound imaging
-
G. R. Lockwood, D. H. Turnbull, D. A. Christopher, and F. S. Foster, “Beyond 30 MHz: Applications of high frequency ultrasound imaging,” IEEE Eng. Med. Biol., vol. 15, pp. 60–71, 1996.
-
(1996)
IEEE Eng. Med. Biol.
, vol.15
, pp. 60-71
-
-
Lockwood, G.R.1
Turnbull, D.H.2
Christopher, D.A.3
Foster, F.S.4
-
3
-
-
0031079960
-
Improved system for sonographic imaging and biometry of the cornea
-
R. H. Silverman, D. Z. Reinstein, T. Raevsky, and D. J. Coleman, “Improved system for sonographic imaging and biometry of the cornea,” J. Ultras. Med., vol. 16, pp. 117–124, 1995.
-
(1995)
J. Ultras. Med.
, vol.16
, pp. 117-124
-
-
Silverman, R.H.1
Reinstein, D.Z.2
Raevsky, T.3
Coleman, D.J.4
-
4
-
-
0028896445
-
A 40–100 MHz B-scan ultrasound backscatter microscopy for skin imaging
-
D. H. Turnbull, B. G. Starkoski, K. A. Harasiewicz, J. L. Semple, L. From, A. K. Gupta, D. N. Sauder, and F. S. Foster, “A 40–100 MHz B-scan ultrasound backscatter microscopy for skin imaging,” Ultrasound Med. Biol., vol. 21, pp. 79–88, 1995.
-
(1995)
Ultrasound Med. Biol.
, vol.21
, pp. 79-88
-
-
Turnbull, D.H.1
Starkoski, B.G.2
Harasiewicz, K.A.3
Semple, J.L.4
From, L.5
Gupta, A.K.6
Sauder, D.N.7
Foster, F.S.8
-
5
-
-
0027883590
-
In vivo ultrasound biomicroscopy
-
C. Passmann, H. Ermert, T. Auer, K. Kaspar, S. el-Gammal, and P. Altmeyer, “In vivo ultrasound biomicroscopy Proc. IEEE Ultrason. Symp., 1993, pp. 1015–1018.
-
(1993)
Proc. IEEE Ultrason. Symp.
, pp. 1015-1018
-
-
Passmann, C.1
Ermert, H.2
Auer, T.3
Kaspar, K.4
el-Gammal, S.5
Altmeyer, P.6
-
6
-
-
0030196861
-
A 100 MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics
-
C. Passmann and H. Ermert, “A 100 MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 43, no. 4, pp. 545–552, 1996.
-
(1996)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.43
, Issue.4
, pp. 545-552
-
-
Passmann, C.1
Ermert, H.2
-
7
-
-
0028925939
-
Ultrasound backscatter microscope analysis of early mouse embryonic brain development
-
D. H. Turnbull, T. S. Bloomfield, F. S. Foster, and A. L. Joyner, “Ultrasound backscatter microscope analysis of early mouse embryonic brain development,” Proc. Natl. Acad. Sci., vol. 92, no. 6, pp. 2239–2243, 1995.
-
(1995)
Proc. Natl. Acad. Sci.
, vol.92
, Issue.6
, pp. 2239-2243
-
-
Turnbull, D.H.1
Bloomfield, T.S.2
Foster, F.S.3
Joyner, A.L.4
-
8
-
-
0032954293
-
In utero ultrasound backscatter microscopy of early stage mouse embryos
-
D. H. Turnbull, “In utero ultrasound backscatter microscopy of early stage mouse embryos,” Comput. Med. Imaging Graphics, vol. 23, no. 1, pp. 25–31, 1999.
-
(1999)
Comput. Med. Imaging Graphics
, vol.23
, Issue.1
, pp. 25-31
-
-
Turnbull, D.H.1
-
9
-
-
0036750352
-
A new ultrasound instrument for in vivo microimaging of mice
-
F. S. Foster, M. Y. Zhang, Y. Q. Zhou, G. Liu, J. Mehi, E. Cherin, K. A. Harasiewicz, B. G. Starkoski, L. Zan, D. A. Knapik, and S. L. Adamson, “A new ultrasound instrument for in vivo microimaging of mice,” Ultrasound Med. Biol., vol. 28, no. 9, pp. 1165–1172, 2002.
-
(2002)
Ultrasound Med. Biol.
, vol.28
, Issue.9
, pp. 1165-1172
-
-
Foster, F.S.1
Zhang, M.Y.2
Zhou, Y.Q.3
Liu, G.4
Mehi, J.5
Cherin, E.6
Harasiewicz, K.A.7
Starkoski, B.G.8
Zan, L.9
Knapik, D.A.10
Adamson, S.L.11
-
11
-
-
4043082664
-
Design and fabrication of annular arrays for high frequency ultrasound
-
J. A. Brown, C. E. M. Demore, and G. R. Lockwood, “Design and fabrication of annular arrays for high frequency ultrasound,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 51, no. 8, pp. 1010–1017, 2004.
-
(2004)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.51
, Issue.8
, pp. 1010-1017
-
-
Brown, J.A.1
Demore, C.E.M.2
Lockwood, G.R.3
-
12
-
-
0035732308
-
Design of a high frequency annular array for medical ultrasound
-
K. A. Snook, T. A. Ritter, T. R. Shrout, and K. K. Shung, “Design of a high frequency annular array for medical ultrasound Proc. IEEE Ultrason. Symp., 2001, pp. 1161–1164.
-
(2001)
Proc. IEEE Ultrason. Symp.
, pp. 1161-1164
-
-
Snook, K.A.1
Ritter, T.A.2
Shrout, T.R.3
Shung, K.K.4
-
13
-
-
0019450840
-
Transient fields of concave annular arrays
-
M. Arditi, F. S. Foster, and J. W. Hunt, “Transient fields of concave annular arrays,” Ultrason. Imag., vol. 3, no. 1, pp. 37–61, 1981.
-
(1981)
Ultrason. Imag.
, vol.3
, Issue.1
, pp. 37-61
-
-
Arditi, M.1
Foster, F.S.2
Hunt, J.W.3
-
14
-
-
0020039808
-
An annular array system for high resolution breast echography
-
M. Arditi, W. B. Taylor, F. S. Foster, and J. W. Hunt, “An annular array system for high resolution breast echography,” Ultrason. Imag., vol. 4, pp. 1–31, 1982.
-
(1982)
Ultrason. Imag.
, vol.4
, pp. 1-31
-
-
Arditi, M.1
Taylor, W.B.2
Foster, F.S.3
Hunt, J.W.4
-
15
-
-
0024764684
-
A closed-form field analysis of a broad band annular array
-
T. K. Song and S. B. Park, “A closed-form field analysis of a broad band annular array,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 36, pp. 661–671, 1989.
-
(1989)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.36
, pp. 661-671
-
-
Song, T.K.1
Park, S.B.2
-
16
-
-
0025483467
-
Ultrasonic nondiffracting transducer for medical imaging
-
J.-Y. Lu and J. F. Greenleaf, “Ultrasonic nondiffracting transducer for medical imaging,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 37, pp. 438–447, 1990.
-
(1990)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.37
, pp. 438-447
-
-
Lu, J.-Y.1
Greenleaf, J.F.2
-
17
-
-
0036012871
-
Molding of CW annular arrays using limited diffraction Bessel beams
-
P. D. Fox and S. Holm, “Molding of CW annular arrays using limited diffraction Bessel beams,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 49, pp. 85–93, 2002.
-
(2002)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.49
, pp. 85-93
-
-
Fox, P.D.1
Holm, S.2
-
18
-
-
85047683359
-
Fourier-Bessel field calculation and tuning of a CW annular array
-
P. D. Fox, J. Cheng, and J.-Y. Lu, “Fourier-Bessel field calculation and tuning of a CW annular array,” IEEE Trans. Ultrason., Ferroelect., Freq Contr. vol. 49, pp. 1179–1190, 2002.
-
(2002)
IEEE Trans. Ultrason., Ferroelect., Freq Contr.
, vol.49
, pp. 1179-1190
-
-
Fox, P.D.1
Cheng, J.2
Lu, J.-Y.3
-
19
-
-
0032265311
-
Nondiffraction beam generated from an annular array driven by uniform velocity amplitude
-
T. Yokoyama, H. Masuyama, and K. Nagai, “Nondiffraction beam generated from an annular array driven by uniform velocity amplitude Proc. IEEE Ultrason. Symp., 1998, pp. 1069–1072.
-
(1998)
Proc. IEEE Ultrason. Symp.
, pp. 1069-1072
-
-
Yokoyama, T.1
Masuyama, H.2
Nagai, K.3
-
20
-
-
0020330150
-
A proposed annular array imaging system for contact B-scan applications
-
M. O'Donnell, “A proposed annular array imaging system for contact B-scan applications,” IEEE Trans. Sonics Ultrason., vol. SU-29, no. 6, pp. 331–338, 1982.
-
(1982)
IEEE Trans. Sonics Ultrason.
, vol.SU-29
, Issue.6
, pp. 331-338
-
-
O'Donnell, M.1
-
21
-
-
0024460577
-
Development of a 12 element annular array transducer for real time ultrasound imaging
-
F. S. Foster, J. D. Larson, M. K. Mason, T. S. Shoup, G. Nelson, and H. Yoshida, “Development of a 12 element annular array transducer for real time ultrasound imaging,” Ultrasound Med. Biol., vol. 15, no. 7, pp. 649–659, 1989.
-
(1989)
Ultrasound Med. Biol.
, vol.15
, Issue.7
, pp. 649-659
-
-
Foster, F.S.1
Larson, J.D.2
Mason, M.K.3
Shoup, T.S.4
Nelson, G.5
Yoshida, H.6
-
22
-
-
85008028356
-
Design and testing of an annular array for very high frequency imaging
-
J. A. Ketterling, S. Ramachadran, F. L. Lizzi, O. Aristizabal, and D. H. Turnbull, “Design and testing of an annular array for very high frequency imaging,” J. Acoust. Soc. Amer., vol. 115, no. 5, pp. 2377–2378, 2004.
-
(2004)
J. Acoust. Soc. Amer.
, vol.115
, Issue.5
, pp. 2377-2378
-
-
Ketterling, J.A.1
Ramachadran, S.2
Lizzi, F.L.3
Aristizabal, O.4
Turnbull, D.H.5
-
24
-
-
0036995721
-
Design of a real time digital beamformer for a 50 Mhz annular array transducer
-
P. J. Cao and K. K. Shung, “Design of a real time digital beamformer for a 50 Mhz annular array transducer Proc. IEEE Ultrason. Symp., 2002, pp. 1619–1622.
-
(2002)
Proc. IEEE Ultrason. Symp.
, pp. 1619-1622
-
-
Cao, P.J.1
Shung, K.K.2
-
25
-
-
4143069475
-
Development of a real time digital high frequency annular array ultrasound imaging system
-
P. J. Cao, C. H. Hu, and K. K. Shung, “Development of a real time digital high frequency annular array ultrasound imaging system Proc. IEEE Ultrason. Symp., 2003, pp. 1867–1870.
-
(2003)
Proc. IEEE Ultrason. Symp.
, pp. 1867-1870
-
-
Cao, P.J.1
Hu, C.H.2
Shung, K.K.3
-
26
-
-
33645326266
-
High-frequency ultrasound annular-array imaging. Part I: Array design and fabrication
-
K. A. Snook, C. Hu, T. R. Shrout, and K. K. Shung, “High-frequency ultrasound annular-array imaging. Part I: Array design and fabrication,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 53, no. 2, pp. 299–307, 2006.
-
(2006)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.53
, Issue.2
, pp. 299-307
-
-
Snook, K.A.1
Hu, C.2
Shrout, T.R.3
Shung, K.K.4
-
28
-
-
0035731190
-
Characterization of high-frequency transducers with small aperture hydrophones
-
B. Huang, K. Snook, and K. K. Shung, “Characterization of high-frequency transducers with small aperture hydrophones Proc. IEEE Ultrason. Symp., 2001, pp. 1069–1071.
-
(2001)
Proc. IEEE Ultrason. Symp.
, pp. 1069-1071
-
-
Huang, B.1
Snook, K.2
Shung, K.K.3
-
29
-
-
0030358702
-
Evolution of ultrasound beamformers
-
K. E. Thomenius, “Evolution of ultrasound beamformers Proc. IEEE Ultrason. Symp., 1996, pp. 1615–1622.
-
(1996)
Proc. IEEE Ultrason. Symp.
, pp. 1615-1622
-
-
Thomenius, K.E.1
-
30
-
-
0021466923
-
Real-time digital image reconstruction: A description of imaging hardware and an analysis of quantization errors
-
D. K. Peterson and G. S. Kino, “Real-time digital image reconstruction: A description of imaging hardware and an analysis of quantization errors,” IEEE Trans. Sonics Ultrason., vol. SU-31, pp. 337–351, 1984.
-
(1984)
IEEE Trans. Sonics Ultrason.
, vol.SU-31
, pp. 337-351
-
-
Peterson, D.K.1
Kino, G.S.2
-
31
-
-
0026945778
-
Digital beamforming in ultrasound
-
B. D. Steinberg, “Digital beamforming in ultrasound,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 39, pp. 716–721, 1992.
-
(1992)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.39
, pp. 716-721
-
-
Steinberg, B.D.1
-
33
-
-
0021466923
-
Real-time digital image reconstruction: A description of imaging hardware and an analysis of quantization errors
-
D. K. Peterson and G. S. Kino, “Real-time digital image reconstruction: A description of imaging hardware and an analysis of quantization errors,” IEEE Trans. Sonics Ultrason., vol. SU-31, pp. 337–351, 1984.
-
(1984)
IEEE Trans. Sonics Ultrason.
, vol.SU-31
, pp. 337-351
-
-
Peterson, D.K.1
Kino, G.S.2
-
34
-
-
0021445103
-
A comparison of efficient beamforming algorithms
-
R. A. Mucci, “A comparison of efficient beamforming algorithms,” IEEE Trans. Acoust. Speech Signal Processing, vol. ASSP-32, no. 3, pp. 428–557, 1984.
-
(1984)
IEEE Trans. Acoust. Speech Signal Processing
, vol.ASSP-32
, Issue.3
, pp. 428-557
-
-
Mucci, R.A.1
-
35
-
-
0018479351
-
Digital interpolation beamforming for low-pass and band pass signals
-
R. G. Pridham and R. A. Mucci, “Digital interpolation beamforming for low-pass and band pass signals,” J. Acoust. Soc. Amer., vol. 67, no. 6, pp. 904–919, 1979.
-
(1979)
J. Acoust. Soc. Amer.
, vol.67
, Issue.6
, pp. 904-919
-
-
Pridham, R.G.1
Mucci, R.A.2
-
36
-
-
85032783198
-
Splitting the unit delay
-
T. I. Laasko, V. Valimaki, M. Karjalainen, and U. K. Laine, “Splitting the unit delay,” IEEE Signal Processing Magazine, pp. 30–60, 1996.
-
(1996)
IEEE Signal Processing Magazine
, pp. 30-60
-
-
Laasko, T.I.1
Valimaki, V.2
Karjalainen, M.3
Laine, U.K.4
-
37
-
-
0442326648
-
Design of efficient, broadband single-element (20–80 MHz) ultrasonic transducers for medical imaging applications
-
J. M. Cannata, T. A. Ritter, W. H. Chen, R. H. Silverman, and K. K. Shung, “Design of efficient, broadband single-element (20–80 MHz) ultrasonic transducers for medical imaging applications,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 50, no. 11, pp. 1548–1557, 2003.
-
(2003)
IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
, vol.50
, Issue.11
, pp. 1548-1557
-
-
Cannata, J.M.1
Ritter, T.A.2
Chen, W.H.3
Silverman, R.H.4
Shung, K.K.5
|