메뉴 건너뛰기




Volumn 41, Issue 2, 2006, Pages 168-174

Efficacy of cyto-chex blood preservative for delayed manual CD4 testing using dynal T4 quant CD4 test among HIV-infected persons in Zambia

Author keywords

Blood preservation; CD4 lymphocyte count; Cyto Chex (Streck Laboratories, La Vista, NE); Developing countries; Dynabeads (Dynal Biotech, Oslo, Norway); HIV; Resource constrained countries

Indexed keywords

EDETIC ACID; PRESERVATIVE;

EID: 33645279028     PISSN: 15254135     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.qai.0000191282.77954.fc     Document Type: Article
Times cited : (12)

References (21)
  • 2
    • 0038300741 scopus 로고    scopus 로고
    • Monitoring of human immunodeficiency virus infection in resource-constrained countries
    • Crowe S, Turnbull S, Oelrichs R, et al. Monitoring of human immunodeficiency virus infection in resource-constrained countries. Clin Infect Dis. 2003;37(Suppl 1):S25-S35.
    • (2003) Clin Infect Dis , vol.37 , Issue.1 SUPPL.
    • Crowe, S.1    Turnbull, S.2    Oelrichs, R.3
  • 3
    • 10744228347 scopus 로고    scopus 로고
    • Successful implementation of a low-cost method for enumerating CD4+ T lymphocytes in resource-limited settings: The ANRS 12-26 study
    • Diagbouga S, Chazallon C, Kazatchkine MD, et al. Successful implementation of a low-cost method for enumerating CD4+ T lymphocytes in resource-limited settings: the ANRS 12-26 study. AIDS. 2003;17:2201-2208.
    • (2003) AIDS , vol.17 , pp. 2201-2208
    • Diagbouga, S.1    Chazallon, C.2    Kazatchkine, M.D.3
  • 4
    • 0035251418 scopus 로고    scopus 로고
    • Comparative assessment of five alternative methods for CD4+ T-lymphocyte enumeration for implementation in developing countries
    • Didier JM, Kazatchkine MD, Demouchy C, et al. Comparative assessment of five alternative methods for CD4+ T-lymphocyte enumeration for implementation in developing countries. J Acquir Immune Defic Syndr. 2001;26:193-195.
    • (2001) J Acquir Immune Defic Syndr , vol.26 , pp. 193-195
    • Didier, J.M.1    Kazatchkine, M.D.2    Demouchy, C.3
  • 5
    • 0030576909 scopus 로고    scopus 로고
    • Evaluation of the FACScount, TRAx CD4 and Dynabeads methods for CD4 lymphocyte determination
    • Lyamuya EF, Kagoma C, Mbena EC, et al. Evaluation of the FACScount, TRAx CD4 and Dynabeads methods for CD4 lymphocyte determination. J Immunol Methods. 1996;195:103-112.
    • (1996) J Immunol Methods , vol.195 , pp. 103-112
    • Lyamuya, E.F.1    Kagoma, C.2    Mbena, E.C.3
  • 6
    • 0027750898 scopus 로고
    • A rapid manual method for CD4+ T-cell quantitation for use in developing countries
    • Landay A, Ho JL, Hom D, et al. A rapid manual method for CD4+ T-cell quantitation for use in developing countries. AIDS. 1993;7:1565-1568.
    • (1993) AIDS , vol.7 , pp. 1565-1568
    • Landay, A.1    Ho, J.L.2    Hom, D.3
  • 7
    • 0029154054 scopus 로고
    • Determination of CD4+ and CD8+ lymphocytes with the cytosphere assay: A comparative study with flow cytometry and the immunoalkaline phosphatase method
    • Gernow A, Lisse IM, Böttiger B, et al. Determination of CD4+ and CD8+ lymphocytes with the cytosphere assay: a comparative study with flow cytometry and the immunoalkaline phosphatase method. Clin Immunol Immunopathol. 1995;76:135-141.
    • (1995) Clin Immunol Immunopathol , vol.76 , pp. 135-141
    • Gernow, A.1    Lisse, I.M.2    Böttiger, B.3
  • 8
    • 33646025337 scopus 로고    scopus 로고
    • Storage of processed cord blood samples prior to staining for white blood subsets
    • Childs CR, Helm K, Bryant M, et al. Storage of processed cord blood samples prior to staining for white blood subsets [abstract]. Cytotherapy. 1999;1:231.
    • (1999) Cytotherapy , vol.1 , pp. 231
    • Childs, C.R.1    Helm, K.2    Bryant, M.3
  • 9
    • 0033667566 scopus 로고    scopus 로고
    • Stability of fresh and preserved fetal and adult lymphocyte cell surface markers
    • Schumacher MJ, Burkhead T. Stability of fresh and preserved fetal and adult lymphocyte cell surface markers. J Clin Lab Anal. 2000;14:320-326.
    • (2000) J Clin Lab Anal , vol.14 , pp. 320-326
    • Schumacher, M.J.1    Burkhead, T.2
  • 10
    • 0030236183 scopus 로고    scopus 로고
    • A reagent for stabilizing blood samples
    • Turpen PB, Collins M. A reagent for stabilizing blood samples. Am Clin Lab. 1996;15:30-31.
    • (1996) Am Clin Lab , vol.15 , pp. 30-31
    • Turpen, P.B.1    Collins, M.2
  • 11
    • 0037092123 scopus 로고    scopus 로고
    • CD45-assisted panLeucogating for accurate, cost-effective dual-platform CD4+ T-cell enumeration
    • Glencross D, Scott LE, Jani IV, et al. CD45-assisted panLeucogating for accurate, cost-effective dual-platform CD4+ T-cell enumeration. Cytometry. 2002;50:69-77.
    • (2002) Cytometry , vol.50 , pp. 69-77
    • Glencross, D.1    Scott, L.E.2    Jani, I.V.3
  • 12
    • 0035514480 scopus 로고    scopus 로고
    • Affordable CD4+ T cell counts by flow cytometry: II: The use of fixed whole blood in resource-poor settings
    • Jani IV, Janossy G, Iqbal A, et al. Affordable CD4+ T cell counts by flow cytometry: II: the use of fixed whole blood in resource-poor settings. J Immunol Methods. 2001;257:145-154.
    • (2001) J Immunol Methods , vol.257 , pp. 145-154
    • Jani, I.V.1    Janossy, G.2    Iqbal, A.3
  • 13
    • 33444473288 scopus 로고    scopus 로고
    • A robust whole blood preparation for absolute counting
    • Abstract
    • Shafaie A, Bergeron M, Phaneuf S, et al. A robust whole blood preparation for absolute counting. Cytometry. 2000;(Suppl 10):145. Abstract.
    • (2000) Cytometry , Issue.10 SUPPL. , pp. 145
    • Shafaie, A.1    Bergeron, M.2    Phaneuf, S.3
  • 14
    • 1842444807 scopus 로고    scopus 로고
    • TransFixed whole blood may be a QC solution for the single platform cell enumeration
    • Abstract
    • Shafaie A, Bergeron M, Mandy F, et al. TransFixed whole blood may be a QC solution for the single platform cell enumeration. Cytometry. 2000;(Suppl 10):146. Abstract.
    • (2000) Cytometry , Issue.10 SUPPL. , pp. 146
    • Shafaie, A.1    Bergeron, M.2    Mandy, F.3
  • 15
    • 0002889555 scopus 로고    scopus 로고
    • TransFix: A clinical sample stabilizing fluid for use in cellular haematology and immunology
    • Abstract
    • Barnett D, Granger V, Pockley AG, et al. TransFix: a clinical sample stabilizing fluid for use in cellular haematology and immunology Cytometry. 1999;38:88. Abstract.
    • (1999) Cytometry , vol.38 , pp. 88
    • Barnett, D.1    Granger, V.2    Pockley, A.G.3
  • 16
    • 0242266578 scopus 로고    scopus 로고
    • Use of dried whole blood spots to measure CD4+ lymphocyte counts in HIV-1-infected patients
    • Mwaba P, Cassol S, Pilon R, et al. Use of dried whole blood spots to measure CD4+ lymphocyte counts in HIV-1-infected patients. Lancet. 2003;362:1459-1460.
    • (2003) Lancet , vol.362 , pp. 1459-1460
    • Mwaba, P.1    Cassol, S.2    Pilon, R.3
  • 17
    • 1542376684 scopus 로고    scopus 로고
    • Dried blood spot technology for CD4+ T-cell counting
    • Correspondence
    • Shapiro HM, Mandy FF, Rinke de Wit TF, et al. Dried blood spot technology for CD4+ T-cell counting. Lancet. 2004;363:164. Correspondence.
    • (2004) Lancet , vol.363 , pp. 164
    • Shapiro, H.M.1    Mandy, F.F.2    Rinke De Wit, T.F.3
  • 18
    • 0028847153 scopus 로고
    • Evaluation of four alternative methodologies for determination of absolute CD4+ lymphocyte counts. The National Heart, Lung, and Blood Institute Retrovirus Epidemiology Donor Study
    • Johnson D, Hirschkorn D, Busch MP. Evaluation of four alternative methodologies for determination of absolute CD4+ lymphocyte counts. The National Heart, Lung, and Blood Institute Retrovirus Epidemiology Donor Study. J Acquir Immune Defic Syndr Hum Retrovirol. 1995;10:522-530.
    • (1995) J Acquir Immune Defic Syndr Hum Retrovirol , vol.10 , pp. 522-530
    • Johnson, D.1    Hirschkorn, D.2    Busch, M.P.3
  • 19
    • 0029862203 scopus 로고    scopus 로고
    • Comparison of absolute CD4+ lymphocyte counts determined by enzyme immunoassay (TRAx CD4 test kit) and flow cytometry
    • Moss MW, Carella AV, Provost V, et al. Comparison of absolute CD4+ lymphocyte counts determined by enzyme immunoassay (TRAx CD4 test kit) and flow cytometry. Clin Diagn Lab Immunol. 1996;3:371-373.
    • (1996) Clin Diagn Lab Immunol , vol.3 , pp. 371-373
    • Moss, M.W.1    Carella, A.V.2    Provost, V.3
  • 20
    • 0028800492 scopus 로고
    • Comparison of CD4 cell count by a simple enzyme-linked immunosorbent assay using the TRAx CD4 test kit and by flow cytometry and hematology
    • Paxton H, Pins M, Denton G, et al. Comparison of CD4 cell count by a simple enzyme-linked immunosorbent assay using the TRAx CD4 test kit and by flow cytometry and hematology. Clin Diagn Lab Immunol. 1995;2:104-114.
    • (1995) Clin Diagn Lab Immunol , vol.2 , pp. 104-114
    • Paxton, H.1    Pins, M.2    Denton, G.3
  • 21
    • 0031467969 scopus 로고    scopus 로고
    • Helper T-lymphocyte count: TRAx CD4 test kit versus conventional flow cytometry
    • Saah AJ, Spruill C, Hoover DR, et al. Helper T-lymphocyte count: TRAx CD4 test kit versus conventional flow cytometry. Arch Pathol Lab Med. 1997;121:960-962.
    • (1997) Arch Pathol Lab Med , vol.121 , pp. 960-962
    • Saah, A.J.1    Spruill, C.2    Hoover, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.