메뉴 건너뛰기




Volumn 11, Issue 4, 2006, Pages 61-

Interventions for mobility and manipulation after spinal cord injury: A review of orthotic and neuroprosthetic options

Author keywords

ADL; Ambulation; Functional electrical stimulation; Grasp; Hand and arm function; Orthoses; Reach; Standing

Indexed keywords

ARM MOVEMENT; BRACE; ELECTROSTIMULATION; HAND MOVEMENT; HUMAN; JOINT FUNCTION; LEG MOVEMENT; LIMB MOVEMENT; MOBILIZATION; MUSCLE CONTRACTION; ORTHOSIS; PARALYSIS; PROSTHESIS; REVIEW; SPINAL CORD INJURY; STANDING; TECHNOLOGY; WRIST;

EID: 33645035455     PISSN: 10820744     EISSN: None     Source Type: Journal    
DOI: 10.1310/9UU4-KL3V-CPL2-Q7VF     Document Type: Review
Times cited : (7)

References (103)
  • 2
    • 0018409913 scopus 로고
    • Technical and clinical function testing of hand orthoses in Sweden
    • Dillner S, Georgiev G. Technical and clinical function testing of hand orthoses in Sweden. Int J Rehabil Res. 1979;2(1):47-60.
    • (1979) Int J Rehabil Res , vol.2 , Issue.1 , pp. 47-60
    • Dillner, S.1    Georgiev, G.2
  • 4
    • 0002541261 scopus 로고    scopus 로고
    • Tetraplegia
    • Green DP, Hotchkiss RN, Pederson WC, Lampert R, eds. New York: Churchill Livingstone
    • McDowell CL, House JH. Tetraplegia. In: Green DP, Hotchkiss RN, Pederson WC, Lampert R, eds. Green's Operative Hand Surgery. New York: Churchill Livingstone; 1999:1588-1606.
    • (1999) Green's Operative Hand Surgery , pp. 1588-1606
    • McDowell, C.L.1    House, J.H.2
  • 6
    • 33645016627 scopus 로고    scopus 로고
    • Upper extremity orthotics
    • DeLisa JA, Gans BM, Walsh NE, eds. Philadelphia, PA: Lippincott Williams & Wilkins
    • Uustal H. Upper extremity orthotics. In: DeLisa JA, Gans BM, Walsh NE, eds. Physical Medicine and Rehabilitation Principles and Practice, Vol. 2. 4th ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2005:1367-1376.
    • (2005) Physical Medicine and Rehabilitation Principles and Practice, Vol. 2. 4th Ed. , vol.2 , pp. 1367-1376
    • Uustal, H.1
  • 7
    • 0018174040 scopus 로고
    • Functional ratchet orthotic system
    • Hoy DJ. Functional ratchet orthotic system. Orthot Prosthet. 1978;32:21.
    • (1978) Orthot Prosthet , vol.32 , pp. 21
    • Hoy, D.J.1
  • 8
    • 33645017750 scopus 로고
    • Upper limb bracing
    • Licht S, Kamenetz HL, eds. Physical Medicine Library. Baltimore, MD: Waverly Press
    • Long C. Upper limb bracing. In: Licht S, Kamenetz HL, eds. Orthotics Etcetera. Volume 9, Physical Medicine Library. Baltimore, MD: Waverly Press; 1966:152-248.
    • (1966) Orthotics Etcetera , vol.9 , pp. 152-248
    • Long, C.1
  • 12
    • 0034098622 scopus 로고    scopus 로고
    • Use of the NESS handmaster to restore handfunction in tetraplegia: Clinical experiences in ten patients
    • Snoek GJ, IJzerman MJ, in't Groen FA, Stoffers TS, Zilvold G. Use of the NESS handmaster to restore handfunction in tetraplegia: clinical experiences in ten patients. Spinal Cord. 2000;38(4):244-249.
    • (2000) Spinal Cord , vol.38 , Issue.4 , pp. 244-249
    • Snoek, G.J.1    Ijzerman, M.J.2    In't Groen, F.A.3    Stoffers, T.S.4    Zilvold, G.5
  • 13
    • 0030924758 scopus 로고    scopus 로고
    • The bionic glove: An electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia
    • Prochazka A, Gauthier M, Wieler M, Kenwell Z. The bionic glove: an electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia. Arch Phys Med Rehabil. 1997;78(6):608-614.
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.6 , pp. 608-614
    • Prochazka, A.1    Gauthier, M.2    Wieler, M.3    Kenwell, Z.4
  • 15
    • 0028944763 scopus 로고
    • An EMG-controlled grasping system for tetraplegics
    • Saxena S, Nikolic S, Popovic D. An EMG-controlled grasping system for tetraplegics. J Rehabil Res Dev. 1995;32(1):17-24.
    • (1995) J Rehabil Res Dev , vol.32 , Issue.1 , pp. 17-24
    • Saxena, S.1    Nikolic, S.2    Popovic, D.3
  • 16
    • 0033028504 scopus 로고    scopus 로고
    • Functional control of the hand in tetraplegics based on residual synergistic EMG activity
    • Thorsen R, Ferrarin M, Spadone R, Frigo C. Functional control of the hand in tetraplegics based on residual synergistic EMG activity. Artif Organs. 1999;23(5):470-473.
    • (1999) Artif Organs , vol.23 , Issue.5 , pp. 470-473
    • Thorsen, R.1    Ferrarin, M.2    Spadone, R.3    Frigo, C.4
  • 17
    • 0023615850 scopus 로고
    • Functional electrical stimulation for the control of the upper extremities
    • Handa Y, Hoshimiya N. Functional electrical stimulation for the control of the upper extremities. Med Prog Technol. 1987;12(1-2):51-63.
    • (1987) Med Prog Technol , vol.12 , Issue.1-2 , pp. 51-63
    • Handa, Y.1    Hoshimiya, N.2
  • 18
    • 0019133932 scopus 로고
    • Restoration of key grip and release in the C6 tetraplegic patient through functional electrical stimulation
    • Peckham PH, Marsolais EB, Mortimer JT. Restoration of key grip and release in the C6 tetraplegic patient through functional electrical stimulation. J Hand Surg [Am]. 1980;5(5):462-469.
    • (1980) J Hand Surg [Am] , vol.5 , Issue.5 , pp. 462-469
    • Peckham, P.H.1    Marsolais, E.B.2    Mortimer, J.T.3
  • 19
    • 0027017689 scopus 로고
    • Functional electrical stimulation (FES) systems for restoration of motor function of paralyzed muscles-versatile systems and a portable system
    • Handa Y, Handa T, Ichie M, Murakami H, Hoshimiya N, Ishikawa S, Ohkubo K. Functional electrical stimulation (FES) systems for restoration of motor function of paralyzed muscles-versatile systems and a portable system. Front Med Biol Eng. 1992;4(4):241-255.
    • (1992) Front Med Biol Eng , vol.4 , Issue.4 , pp. 241-255
    • Handa, Y.1    Handa, T.2    Ichie, M.3    Murakami, H.4    Hoshimiya, N.5    Ishikawa, S.6    Ohkubo, K.7
  • 20
    • 0034785252 scopus 로고    scopus 로고
    • Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: A multicenter study
    • Peckham PH, Keith MW, Kilgore KL, et al. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study. Arch Phys Med Rehabil. 2001;82(10):1380-1388.
    • (2001) Arch Phys Med Rehabil , vol.82 , Issue.10 , pp. 1380-1388
    • Peckham, P.H.1    Keith, M.W.2    Kilgore, K.L.3
  • 21
    • 0036127135 scopus 로고    scopus 로고
    • An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller
    • Peckham PH, Kilgore KL, Keith MW, Bryden AM, Bhadra N, Montague FW. An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller. J Hand Surg [Am]. 2002;27(2):265-276.
    • (2002) J Hand Surg [Am] , vol.27 , Issue.2 , pp. 265-276
    • Peckham, P.H.1    Kilgore, K.L.2    Keith, M.W.3    Bryden, A.M.4    Bhadra, N.5    Montague, F.W.6
  • 23
    • 0037229499 scopus 로고    scopus 로고
    • Persons with C5 or C6 tetraplegia achieve selected functional gains using a neuroprosthesis
    • Alon G, McBride K. Persons with C5 or C6 tetraplegia achieve selected functional gains using a neuroprosthesis. Arch Phys Med Rehabil. 2003;84(1):119-124.
    • (2003) Arch Phys Med Rehabil , vol.84 , Issue.1 , pp. 119-124
    • Alon, G.1    McBride, K.2
  • 24
    • 0023378409 scopus 로고
    • An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle
    • Smith B, Peckham PH, Keith MW, Roscoe DD. An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle. IEEE Trans Biomed Eng. 1987;34(7):499-508.
    • (1987) IEEE Trans Biomed Eng , vol.34 , Issue.7 , pp. 499-508
    • Smith, B.1    Peckham, P.H.2    Keith, M.W.3    Roscoe, D.D.4
  • 26
    • 0033840747 scopus 로고    scopus 로고
    • Australian experience with the Freehand System for restoring grasp in quadriplegia
    • Carroll S, Cooper C, Brown D, Sormann G, Flood S, Denison M. Australian experience with the Freehand System for restoring grasp in quadriplegia. Aust N Z J Surg. 2000;70(8):563-568.
    • (2000) Aust N Z J Surg , vol.70 , Issue.8 , pp. 563-568
    • Carroll, S.1    Cooper, C.2    Brown, D.3    Sormann, G.4    Flood, S.5    Denison, M.6
  • 27
    • 3042825153 scopus 로고    scopus 로고
    • Implanted neuroprostheses for restoration of hand function in tetraplegic patients
    • Cornwall R, Hausman MR. Implanted neuroprostheses for restoration of hand function in tetraplegic patients. J Am Acad Orthop Surg. 2004;12(2):72-79.
    • (2004) J Am Acad Orthop Surg , vol.12 , Issue.2 , pp. 72-79
    • Cornwall, R.1    Hausman, M.R.2
  • 28
    • 0030980252 scopus 로고    scopus 로고
    • Implanted functional electrical stimulation hand system in adolescents with spinal injuries: An evaluation
    • Mulcahey MJ, Betz RR, Smith BT, Weiss AA, Davis SE. Implanted functional electrical stimulation hand system in adolescents with spinal injuries: an evaluation. Arch Phys Med Rehabil. 1997;78(6):597-607.
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.6 , pp. 597-607
    • Mulcahey, M.J.1    Betz, R.R.2    Smith, B.T.3    Weiss, A.A.4    Davis, S.E.5
  • 29
    • 0034767839 scopus 로고    scopus 로고
    • Restoration of tetraplegic hand function by use of the neurocontrol freehand system
    • Hobby J, Taylor PN, Esnouf J. Restoration of tetraplegic hand function by use of the neurocontrol freehand system. J Hand Surg [Br]. 2001;26(5):459-464.
    • (2001) J Hand Surg [Br] , vol.26 , Issue.5 , pp. 459-464
    • Hobby, J.1    Taylor, P.N.2    Esnouf, J.3
  • 33
    • 0032103958 scopus 로고    scopus 로고
    • A comparison between control methods for implanted FES hand-grasp systems
    • Hart RL, Kilgore KL, Peckham PH. A comparison between control methods for implanted FES hand-grasp systems. IEEE Trans Rehabil Eng. 1998;6(2):208-218.
    • (1998) IEEE Trans Rehabil Eng , vol.6 , Issue.2 , pp. 208-218
    • Hart, R.L.1    Kilgore, K.L.2    Peckham, P.H.3
  • 34
    • 0009749295 scopus 로고    scopus 로고
    • Electrically stimulated elbow extension in persons with C5/C6 tetraplegia: A functional and physiological evaluation
    • Bryden AM, Memberg WD, Crago PE. Electrically stimulated elbow extension in persons with C5/C6 tetraplegia: a functional and physiological evaluation. Arch Phys Med Rehabil. 2000;81(1):80-88.
    • (2000) Arch Phys Med Rehabil , vol.81 , Issue.1 , pp. 80-88
    • Bryden, A.M.1    Memberg, W.D.2    Crago, P.E.3
  • 35
    • 0346880312 scopus 로고    scopus 로고
    • Restoration of elbow extension via functional electrical stimulation in individuals with tetraplegia
    • Memberg WD, Crago PE, Keith MW. Restoration of elbow extension via functional electrical stimulation in individuals with tetraplegia. J Rehabil Res Dev. 2003;40(6):477-486.
    • (2003) J Rehabil Res Dev , vol.40 , Issue.6 , pp. 477-486
    • Memberg, W.D.1    Crago, P.E.2    Keith, M.W.3
  • 36
    • 0030468938 scopus 로고    scopus 로고
    • Development of an upper extremity FES system for individuals with C4 tetraplegia
    • Smith BT, Mulcahey MJ, Betz RR. Development of an upper extremity FES system for individuals with C4 tetraplegia. IEEE Trans Rehabil Eng. 1996;4(4):264-270.
    • (1996) IEEE Trans Rehabil Eng , vol.4 , Issue.4 , pp. 264-270
    • Smith, B.T.1    Mulcahey, M.J.2    Betz, R.R.3
  • 38
    • 0031741295 scopus 로고    scopus 로고
    • Application of functional electrical stimulation to the paralyzed extremities
    • Handa Y, Yagi R, Hoshimiya N. Application of functional electrical stimulation to the paralyzed extremities. Neurol Med Chir (Tokyo). 1998;38(11):784-788.
    • (1998) Neurol Med Chir (Tokyo) , vol.38 , Issue.11 , pp. 784-788
    • Handa, Y.1    Yagi, R.2    Hoshimiya, N.3
  • 39
    • 0024761981 scopus 로고
    • An FNS-based system for generating upper limb function in the C4 quadriplegic
    • Nathan RH. An FNS-based system for generating upper limb function in the C4 quadriplegic. Med Biol Eng Computing. 1989;27:549-556.
    • (1989) Med Biol Eng Computing , vol.27 , pp. 549-556
    • Nathan, R.H.1
  • 41
    • 0036994474 scopus 로고    scopus 로고
    • Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
    • Tyler DJ, Durand DM. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. IEEE Trans Neural Syst Rehabil Eng. 2002;10(4):294-303.
    • (2002) IEEE Trans Neural Syst Rehabil Eng , vol.10 , Issue.4 , pp. 294-303
    • Tyler, D.J.1    Durand, D.M.2
  • 42
    • 2942653497 scopus 로고    scopus 로고
    • Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode
    • Tarler MD, Mortimer JT. Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode. IEEE Trans Neural Syst Rehabil Eng. 2004;12(2):251-257.
    • (2004) IEEE Trans Neural Syst Rehabil Eng , vol.12 , Issue.2 , pp. 251-257
    • Tarler, M.D.1    Mortimer, J.T.2
  • 44
    • 0037036102 scopus 로고    scopus 로고
    • Direct cortical control of 3D neuroprosthetic devices
    • Taylor DM, Tillery SI, Schwartz AB. Direct cortical control of 3D neuroprosthetic devices. Science. 2002;296(5574):1829-1832.
    • (2002) Science , vol.296 , Issue.5574 , pp. 1829-1832
    • Taylor, D.M.1    Tillery, S.I.2    Schwartz, A.B.3
  • 45
    • 0017851077 scopus 로고
    • Assessment of orthoses by means of speed and heart rate
    • Stallard R, Tait D. Assessment of orthoses by means of speed and heart rate. J Med Eng Tech. 1978;2(1):22-24.
    • (1978) J Med Eng Tech , vol.2 , Issue.1 , pp. 22-24
    • Stallard, R.1    Tait, D.2
  • 46
    • 0031675374 scopus 로고    scopus 로고
    • A medial linkage orthosis to assist ambulation after spinal cord injury
    • Middleton JW, Fisher W, Davis GM, Smith RM. A medial linkage orthosis to assist ambulation after spinal cord injury. Prosthet Orthot Int. 1998;22(3):258-264.
    • (1998) Prosthet Orthot Int , vol.22 , Issue.3 , pp. 258-264
    • Middleton, J.W.1    Fisher, W.2    Davis, G.M.3    Smith, R.M.4
  • 47
    • 0032778532 scopus 로고    scopus 로고
    • Postural control during stance in paraplegia: Effects of medially linked versus unlinked knee-ankle-foot orthoses
    • Middleton JW, Sinclair PJ, Smith RM, Davis GM. Postural control during stance in paraplegia: effects of medially linked versus unlinked knee-ankle-foot orthoses. Arch Phys Med Rehabil. 1999;80(12):1558-1565.
    • (1999) Arch Phys Med Rehabil , vol.80 , Issue.12 , pp. 1558-1565
    • Middleton, J.W.1    Sinclair, P.J.2    Smith, R.M.3    Davis, G.M.4
  • 48
    • 0030152820 scopus 로고    scopus 로고
    • Clinical experience with a new hip-knee-ankle-foot orthotic system using a medial single hip joint for paraplegic standing and walking
    • Saitoh E, Suzuki T, Sonoda S, Fujitani J, Tomita Y, Chino N. Clinical experience with a new hip-knee-ankle-foot orthotic system using a medial single hip joint for paraplegic standing and walking. Am J Phys Med Rehabil. 1996;75(3):198-203.
    • (1996) Am J Phys Med Rehabil , vol.75 , Issue.3 , pp. 198-203
    • Saitoh, E.1    Suzuki, T.2    Sonoda, S.3    Fujitani, J.4    Tomita, Y.5    Chino, N.6
  • 51
    • 0030752710 scopus 로고    scopus 로고
    • A comparison of the attitude of paraplegic individuals to the walkabout orthosis and the isocentric reciprocal gait orthosis
    • Harvey LA, Newton-John T, Davis GM, Smith MB, Engel S. A comparison of the attitude of paraplegic individuals to the walkabout orthosis and the isocentric reciprocal gait orthosis. Spinal Cord. 1997;35(9):580-584.
    • (1997) Spinal Cord , vol.35 , Issue.9 , pp. 580-584
    • Harvey, L.A.1    Newton-John, T.2    Davis, G.M.3    Smith, M.B.4    Engel, S.5
  • 52
    • 0031852735 scopus 로고    scopus 로고
    • Energy expenditure during gait using the walkabout and isocentric reciprocal gait orthoses in persons with paraplegia
    • Harvey LA, Davis GM, Smith MB, Engel S. Energy expenditure during gait using the walkabout and isocentric reciprocal gait orthoses in persons with paraplegia. Arch Phys Med Rehabil. 1998;79(8):945-949.
    • (1998) Arch Phys Med Rehabil , vol.79 , Issue.8 , pp. 945-949
    • Harvey, L.A.1    Davis, G.M.2    Smith, M.B.3    Engel, S.4
  • 53
    • 0345268737 scopus 로고    scopus 로고
    • A prototype of an adjustable advanced reciprocating gait orthosis (ARGO) for spinal cord injury (SCI)
    • Scivoletto G, Mancini M, Fiorelli E, Morganti B, Molinari M. A prototype of an adjustable advanced reciprocating gait orthosis (ARGO) for spinal cord injury (SCI). Spinal Cord. 2003;41(3):187-191.
    • (2003) Spinal Cord , vol.41 , Issue.3 , pp. 187-191
    • Scivoletto, G.1    Mancini, M.2    Fiorelli, E.3    Morganti, B.4    Molinari, M.5
  • 54
    • 0018344707 scopus 로고
    • The principles and practice of hip guidance articulations
    • Rose GK. The principles and practice of hip guidance articulations. Prosthet Orthot Int. 1979;3:37-43.
    • (1979) Prosthet Orthot Int , vol.3 , pp. 37-43
    • Rose, G.K.1
  • 55
    • 0026028062 scopus 로고
    • A clinical review of adult paraplegic patients with complete lesions using the ORLAU ParaWalker
    • Moore P, Stallard J. A clinical review of adult paraplegic patients with complete lesions using the ORLAU ParaWalker. Paraplegia. 1991;29:191-196.
    • (1991) Paraplegia , vol.29 , pp. 191-196
    • Moore, P.1    Stallard, J.2
  • 56
    • 84965590180 scopus 로고
    • Paraplegic walking
    • Whittle MW. Paraplegic walking. Clin Rehabil. 1988;2:45-49.
    • (1988) Clin Rehabil , vol.2 , pp. 45-49
    • Whittle, M.W.1
  • 57
    • 0023475350 scopus 로고
    • Dynamics of reciprocal gait of adult paraplegics using the ParaWalker (hip guidance orthosis)
    • Nene AV, Major RE. Dynamics of reciprocal gait of adult paraplegics using the ParaWalker (hip guidance orthosis). Prosthet Orthot Int. 1987;11:124-127.
    • (1987) Prosthet Orthot Int , vol.11 , pp. 124-127
    • Nene, A.V.1    Major, R.E.2
  • 58
    • 0026503455 scopus 로고
    • Physiologic cost index of paraplegic locomotion using the ORLAU ParaWalker
    • Nene AV, Jennings SJ. Physiologic cost index of paraplegic locomotion using the ORLAU ParaWalker. Paraplegia. 1992;30(4):246-252.
    • (1992) Paraplegia , vol.30 , Issue.4 , pp. 246-252
    • Nene, A.V.1    Jennings, S.J.2
  • 60
    • 0031470988 scopus 로고    scopus 로고
    • A new concept of dynamic orthosis for paraplegia: The weight-bearing control orthosis (WBC)
    • Yano H, Kaneko S, Nakazawa K, Yamamoto SI, Bettoh A. A new concept of dynamic orthosis for paraplegia: the weight-bearing control orthosis (WBC). Prosthet Orthot Int. 1997;21(3):222-228.
    • (1997) Prosthet Orthot Int , vol.21 , Issue.3 , pp. 222-228
    • Yano, H.1    Kaneko, S.2    Nakazawa, K.3    Yamamoto, S.I.4    Bettoh, A.5
  • 61
    • 0042830571 scopus 로고    scopus 로고
    • Energy expenditure during walking with weight-bearing control (WBC) orthosis in thoracic level of paraplegic patients
    • Kawashima N, Sone Y, Nakazawa K, Akai M, Yano H. Energy expenditure during walking with weight-bearing control (WBC) orthosis in thoracic level of paraplegic patients. Spinal Cord. 2003;41(9):506-510.
    • (2003) Spinal Cord , vol.41 , Issue.9 , pp. 506-510
    • Kawashima, N.1    Sone, Y.2    Nakazawa, K.3    Akai, M.4    Yano, H.5
  • 62
    • 0027024195 scopus 로고
    • Lower extremity applications of functional neuromuscular stimulation
    • Jaeger RJ. Lower extremity applications of functional neuromuscular stimulation. Assistive Technol. 1992;4(1):19-30.
    • (1992) Assistive Technol , vol.4 , Issue.1 , pp. 19-30
    • Jaeger, R.J.1
  • 63
    • 0002003827 scopus 로고    scopus 로고
    • Standing and walking with FNS: Technical and clinical challenges
    • Harris G, ed. New York: IEEE Press
    • Triolo RJ, Kobetic R, Betz R. Standing and walking with FNS: technical and clinical challenges. In: Harris G, ed. Human Motion Analysis. New York: IEEE Press; 1996:318-350.
    • (1996) Human Motion Analysis , pp. 318-350
    • Triolo, R.J.1    Kobetic, R.2    Betz, R.3
  • 66
    • 0026528447 scopus 로고
    • Neuromuscular stimulation in spinal cord injury: I. Restoration of functional movement of the extremities
    • Yarcony GM, Rothe EJ, Cybulski GR, Jaeger RJ. Neuromuscular stimulation in spinal cord injury: I. Restoration of functional movement of the extremities. Arch Phys Med Rehabil. 1992;73:78-86.
    • (1992) Arch Phys Med Rehabil , vol.73 , pp. 78-86
    • Yarcony, G.M.1    Rothe, E.J.2    Cybulski, G.R.3    Jaeger, R.J.4
  • 68
    • 0033060401 scopus 로고    scopus 로고
    • Use of functional electrical stimulation in the lower extremities of incomplete spinal cord injured patients
    • Bajd T, Kralj A, Stefancic M, et al. Use of functional electrical stimulation in the lower extremities of incomplete spinal cord injured patients. Artif Organs. 1999;23:403-409.
    • (1999) Artif Organs , vol.23 , pp. 403-409
    • Bajd, T.1    Kralj, A.2    Stefancic, M.3
  • 69
    • 0027199261 scopus 로고
    • The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury-observed benefits during gait studies
    • Granat MH, Ferguson AC, Andrews BJ, et al. The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury-observed benefits during gait studies. Paraplegia. 1993;31:207-215.
    • (1993) Paraplegia , vol.31 , pp. 207-215
    • Granat, M.H.1    Ferguson, A.C.2    Andrews, B.J.3
  • 70
    • 0031006466 scopus 로고    scopus 로고
    • Transcutaneous functional neuromuscular stimulation of certain traumatic complete thoracic paraplegics for independent short-distance ambulation
    • Graupe D, Kohn KH. Transcutaneous functional neuromuscular stimulation of certain traumatic complete thoracic paraplegics for independent short-distance ambulation. Neurol Res. 1997;19(3):323-333.
    • (1997) Neurol Res , vol.19 , Issue.3 , pp. 323-333
    • Graupe, D.1    Kohn, K.H.2
  • 71
    • 0032169132 scopus 로고    scopus 로고
    • Functional neuromuscular stimulator for short-distance ambulation by certain thoracic-level spinal-cord-injured paraplegics
    • Graupe D, Kohn KH. Functional neuromuscular stimulator for short-distance ambulation by certain thoracic-level spinal-cord-injured paraplegics. Surg Neurol. 1998;50(3):202-207.
    • (1998) Surg Neurol , vol.50 , Issue.3 , pp. 202-207
    • Graupe, D.1    Kohn, K.H.2
  • 72
    • 0030853661 scopus 로고    scopus 로고
    • Evaluation of a training program for persons with SCI paraplegia using the Parastep 1 ambulation system: Part 1. Ambulation performance and anthropometric measures
    • Klose KJ, Jacobs PL, Broton JG, et al. Evaluation of a training program for persons with SCI paraplegia using the Parastep 1 ambulation system: part 1. Ambulation performance and anthropometric measures. Arch Phys Med Rehabil. 1997;78(8):789-793.
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.8 , pp. 789-793
    • Klose, K.J.1    Jacobs, P.L.2    Broton, J.G.3
  • 73
    • 0028799357 scopus 로고
    • Restoration of gait by functional electrical stimulation for spinal cord injured patients
    • Gallien P, Brissot R, Eyssette M, Tell L, Barat M, Wiart L, Petit H. Restoration of gait by functional electrical stimulation for spinal cord injured patients. Paraplegia. 1995;33:660-664.
    • (1995) Paraplegia , vol.33 , pp. 660-664
    • Gallien, P.1    Brissot, R.2    Eyssette, M.3    Tell, L.4    Barat, M.5    Wiart, L.6    Petit, H.7
  • 74
    • 0034002630 scopus 로고    scopus 로고
    • Clinical experience with functional electrical stimulation-assisted gait with Parastep in spinal cord-injured patients
    • Brissot R, Gallien P, Le Bot MP, Beaubras A, Laisne D, Beillot J, Dassonville J. Clinical experience with functional electrical stimulation-assisted gait with Parastep in spinal cord-injured patients. Spine. 2000;25(4):501-508.
    • (2000) Spine , vol.25 , Issue.4 , pp. 501-508
    • Brissot, R.1    Gallien, P.2    Le Bot, M.P.3    Beaubras, A.4    Laisne, D.5    Beillot, J.6    Dassonville, J.7
  • 75
    • 0030850531 scopus 로고    scopus 로고
    • Evaluation of a training program for persons with SCI paraplegia using the Parastep 1 ambulation system: Part 5. Lower extremity blood flow and hyperemic response to occlusion are augmented by ambulation training
    • Nash MS, Jacobs PL, Montalvo BM, Klose KJ, Guest RS, Needham-Shropshire BM. Evaluation of a training program for persons with SCI paraplegia using the Parastep 1 ambulation system: part 5. Lower extremity blood flow and hyperemic response to occlusion are augmented by ambulation training. Arch Phys Med Rehabil. 1997;78(8):808-814.
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.8 , pp. 808-814
    • Nash, M.S.1    Jacobs, P.L.2    Montalvo, B.M.3    Klose, K.J.4    Guest, R.S.5    Needham-Shropshire, B.M.6
  • 76
    • 0030876236 scopus 로고    scopus 로고
    • Evaluation of a training program for persons with SCI paraplegia using the Parastep 1 ambulation system: Part 4. Effect on physical self-concept and depression
    • Guest RS, Klose KJ, Needham-Shropshire BM, Jacobs PL. Evaluation of a training program for persons with SCI paraplegia using the Parastep 1 ambulation system: part 4. Effect on physical self-concept and depression. Arch Phys Med Rehabil. 1997;78(8):804-807.
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.8 , pp. 804-807
    • Guest, R.S.1    Klose, K.J.2    Needham-Shropshire, B.M.3    Jacobs, P.L.4
  • 77
    • 0034002630 scopus 로고    scopus 로고
    • Clinical experience with functional electrical stimulation-assisted gait with Parastep in spinal cord-injured patients
    • Brissot R, Gallien P, Le Bot MP, Beaubras A, Laisne D, Beillot J, Dassonville J. Clinical experience with functional electrical stimulation-assisted gait with Parastep in spinal cord-injured patients. Spine. 2000;25(4):501-508.
    • (2000) Spine , vol.25 , Issue.4 , pp. 501-508
    • Brissot, R.1    Gallien, P.2    Le Bot, M.P.3    Beaubras, A.4    Laisne, D.5    Beillot, J.6    Dassonville, J.7
  • 78
    • 0028443327 scopus 로고
    • Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation
    • Kobetic R, Marsolais EB. Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation. IEEE Trans Biomed Eng. 1994;2(2):66-67.
    • (1994) IEEE Trans Biomed Eng , vol.2 , Issue.2 , pp. 66-67
    • Kobetic, R.1    Marsolais, E.B.2
  • 79
    • 0029911085 scopus 로고    scopus 로고
    • Implanted FNS systems for assisted standing and transfers for individuals with cervical spinal cord injuries: Clinical case reports
    • Triolo RJ, Bieri C, Uhlir J, Kobetic R, Scheiner A, Marsolais EB. Implanted FNS systems for assisted standing and transfers for individuals with cervical spinal cord injuries: clinical case reports. Arch Phys Med Rehabil. 1996;7(11):1119-1128.
    • (1996) Arch Phys Med Rehabil , vol.7 , Issue.11 , pp. 1119-1128
    • Triolo, R.J.1    Bieri, C.2    Uhlir, J.3    Kobetic, R.4    Scheiner, A.5    Marsolais, E.B.6
  • 80
    • 0004428877 scopus 로고
    • The next step: Artificial walking
    • Rose J, Ganble JG, eds. Baltimore, MD: Williams & Wilkins
    • Kobetic R, Marsolais EB, Samane P, et al. The next step: artificial walking. In: Rose J, Ganble JG, eds. Human Walking. Baltimore, MD: Williams & Wilkins; 1994:225-252.
    • (1994) Human Walking , pp. 225-252
    • Kobetic, R.1    Marsolais, E.B.2    Samane, P.3
  • 83
    • 0031239099 scopus 로고    scopus 로고
    • Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs
    • Cameron T, Loeb GE, Peck RA. Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs. IEEE Trans Biomed Eng. 1997;44:781-790.
    • (1997) IEEE Trans Biomed Eng , vol.44 , pp. 781-790
    • Cameron, T.1    Loeb, G.E.2    Peck, R.A.3
  • 85
    • 0035708730 scopus 로고    scopus 로고
    • Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers
    • Davis JA, Triolo RJ, Uhlir JP, Bieri C, Rohde L, Lissy D. Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers. J Rehabil Res Dev. 2001;38(6):609-617.
    • (2001) J Rehabil Res Dev , vol.38 , Issue.6 , pp. 609-617
    • Davis, J.A.1    Triolo, R.J.2    Uhlir, J.P.3    Bieri, C.4    Rohde, L.5    Lissy, D.6
  • 86
    • 0031170788 scopus 로고    scopus 로고
    • Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes
    • Akers JM, Peckham PH, Keith MW, Merritt K. Tissue response to chronically stimulated implanted epimysial and intramuscular electrodes. IEEE Trans Rehabil Eng. 1996;5(2):207-220.
    • (1996) IEEE Trans Rehabil Eng , vol.5 , Issue.2 , pp. 207-220
    • Akers, J.M.1    Peckham, P.H.2    Keith, M.W.3    Merritt, K.4
  • 87
    • 0008210246 scopus 로고    scopus 로고
    • A wearable controller for clinical studies involving multi-implant FNS systems
    • Buckett J, Triolo R, Ferencz D, Katorgi M, Bieri C. A wearable controller for clinical studies involving multi-implant FNS systems. J Spinal Cord Med. 1998;21(2):179.
    • (1998) J Spinal Cord Med , vol.21 , Issue.2 , pp. 179
    • Buckett, J.1    Triolo, R.2    Ferencz, D.3    Katorgi, M.4    Bieri, C.5
  • 88
    • 0033408446 scopus 로고    scopus 로고
    • Implanted functional electrical stimulation system for mobility in paraplegia: A follow-up case report
    • Kobetic R, Triolo RJ, Uhlir JP, et al. Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report. IEEE Trans Rehabil Eng. 1999;7:390-398.
    • (1999) IEEE Trans Rehabil Eng , vol.7 , pp. 390-398
    • Kobetic, R.1    Triolo, R.J.2    Uhlir, J.P.3
  • 89
    • 0346880311 scopus 로고    scopus 로고
    • The effects of regular use of neuromuscular electrical stimulation on tissue health
    • Bogie K, Triolo RJ. The effects of regular use of neuromuscular electrical stimulation on tissue health. J Rehabil Res Dev. 2003;40(6):469-476.
    • (2003) J Rehabil Res Dev , vol.40 , Issue.6 , pp. 469-476
    • Bogie, K.1    Triolo, R.J.2
  • 90
    • 0037643534 scopus 로고    scopus 로고
    • Long term user perceptions of an implanted neuroprosthesis for exercise, standing and transfers after spinal cord injury
    • Agarwal S, Triolo RJ, Kobetic R, et al. Long term user perceptions of an implanted neuroprosthesis for exercise, standing and transfers after spinal cord injury. J Rehabil Res Dev. 2003;40(3):214-234.
    • (2003) J Rehabil Res Dev , vol.40 , Issue.3 , pp. 214-234
    • Agarwal, S.1    Triolo, R.J.2    Kobetic, R.3
  • 91
    • 0029347530 scopus 로고
    • Modeling and simulation of paraplegic ambulation in a reciprocating gait orthosis
    • Tashman S, Zajac FE, Perkash I. Modeling and simulation of paraplegic ambulation in a reciprocating gait orthosis. J Biomech Eng. 1995;17:300-308.
    • (1995) J Biomech Eng , vol.17 , pp. 300-308
    • Tashman, S.1    Zajac, F.E.2    Perkash, I.3
  • 92
    • 0031443533 scopus 로고    scopus 로고
    • The influence of the reciprocal hip joint link in the advanced reciprocating gait orthosis on standing performance in paraplegia
    • Baardman G, Ijzerman MJ, Hermens HJ, Veltink PH, Boom HBK, Zilvold G. The influence of the reciprocal hip joint link in the advanced reciprocating gait orthosis on standing performance in paraplegia. Prosthet Orthot Int. 1997;21:210-221.
    • (1997) Prosthet Orthot Int , vol.21 , pp. 210-221
    • Baardman, G.1    Ijzerman, M.J.2    Hermens, H.J.3    Veltink, P.H.4    Boom, H.B.K.5    Zilvold, G.6
  • 93
    • 0031011103 scopus 로고    scopus 로고
    • The influence of the reciprocal cable linkage in the advanced reciprocating orthosis on the paraplegic gait performance
    • Ijzerman MJ, Baardman G, Hermens HJ, Veltink PH, Boom HBK, Zilvold G. The influence of the reciprocal cable linkage in the advanced reciprocating orthosis on the paraplegic gait performance. Prosthet Orthot Int. 1997;21:52-61.
    • (1997) Prosthet Orthot Int , vol.21 , pp. 52-61
    • Ijzerman, M.J.1    Baardman, G.2    Hermens, H.J.3    Veltink, P.H.4    Boom, H.B.K.5    Zilvold, G.6
  • 94
  • 95
    • 1842413032 scopus 로고    scopus 로고
    • Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II). Part I: Performance evaluation of 70 paraplegic patients
    • Solomonow M, Aguilar E, Reisin E, Baratta RV, Best R, Coetzee T, D'Ambrosia R. Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II). Part I: performance evaluation of 70 paraplegic patients. Orthopedics. 1997;20(4):315-324.
    • (1997) Orthopedics , vol.20 , Issue.4 , pp. 315-324
    • Solomonow, M.1    Aguilar, E.2    Reisin, E.3    Baratta, R.V.4    Best, R.5    Coetzee, T.6    D'Ambrosia, R.7
  • 96
    • 1842329203 scopus 로고    scopus 로고
    • Reciprocal gait orthosis powered with electrical muscle stimulation (RGO II). Part II: Medical evaluation of 70 paraplegic patients
    • Solomonow M, Reisin E, Aguilar E, Baratta RV, Best R, D'Ambrosia RD. Reciprocal gait orthosis powered with electrical muscle stimulation (RGO II). Part II: medical evaluation of 70 paraplegic patients. Orthopedics. 1997;20(5):411-418.
    • (1997) Orthopedics , vol.20 , Issue.5 , pp. 411-418
    • Solomonow, M.1    Reisin, E.2    Aguilar, E.3    Baratta, R.V.4    Best, R.5    D'Ambrosia, R.D.6
  • 97
    • 0024317422 scopus 로고
    • The RGO Generation II: Muscle stimulation powered orthosis as a practical walking system for thoracic paraplegics
    • Solomonow M, Baratta R, Hirokawa S, et al. The RGO Generation II: muscle stimulation powered orthosis as a practical walking system for thoracic paraplegics. Orthopedics. 1989;12:1309-1315.
    • (1989) Orthopedics , vol.12 , pp. 1309-1315
    • Solomonow, M.1    Baratta, R.2    Hirokawa, S.3
  • 98
    • 0030013034 scopus 로고    scopus 로고
    • Energy consumption of paraplegic locomotion using reciprocal gait orthosis
    • Beillot J, Carre F, Le Claire G, et al. Energy consumption of paraplegic locomotion using reciprocal gait orthosis. Eur J Appl Physiol. 1996;73:376-381.
    • (1996) Eur J Appl Physiol , vol.73 , pp. 376-381
    • Beillot, J.1    Carre, F.2    Le Claire, G.3
  • 99
    • 0026566365 scopus 로고
    • Ambulation using the reciprocating gait orthosis and functional electrical stimulation
    • Isakov E, Douglas R, Berns P. Ambulation using the reciprocating gait orthosis and functional electrical stimulation. Paraplegia. 1992;30(4):239-245.
    • (1992) Paraplegia , vol.30 , Issue.4 , pp. 239-245
    • Isakov, E.1    Douglas, R.2    Berns, P.3
  • 101
    • 19544362904 scopus 로고    scopus 로고
    • Preliminary design and simulation of a pneumatic, stored-energy, hybrid orthosis for gait restoration
    • November 13-20; Anaheim, CA
    • Durfee WK, Rivard A. Preliminary design and simulation of a pneumatic, stored-energy, hybrid orthosis for gait restoration. In: Proceedings of the ASME International Mechanical Engineering Congress; November 13-20, 2004; Anaheim, CA:1-7.
    • (2004) Proceedings of the ASME International Mechanical Engineering Congress , pp. 1-7
    • Durfee, W.K.1    Rivard, A.2
  • 102
    • 0034198963 scopus 로고    scopus 로고
    • The Case Western Reserve University hybrid gait orthosis
    • Marsolais EB, Kobetic R, Polando G, et al. The Case Western Reserve University hybrid gait orthosis. J Spinal Cord Med. 2000;23(2):100-108.
    • (2000) J Spinal Cord Med , vol.23 , Issue.2 , pp. 100-108
    • Marsolais, E.B.1    Kobetic, R.2    Polando, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.