메뉴 건너뛰기




Volumn 78, Issue 6, 1997, Pages 608-614

The bionic glove: An electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; ELECTROSTIMULATION; FEMALE; GLOVE; HAND FUNCTION; HAND GRIP; HAND MOVEMENT; HUMAN; MALE; MEDICAL INSTRUMENTATION; QUADRIPLEGIA; SPINAL CORD INJURY; STROKE;

EID: 0030924758     PISSN: 00039993     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0003-9993(97)90426-3     Document Type: Article
Times cited : (199)

References (33)
  • 1
    • 73049136842 scopus 로고
    • Functional electrotherapy: Stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients
    • Liberson WT, Holmquest HJ, Scott D, Dow M. Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch Phys Med Rehabil 1961;42:101-5.
    • (1961) Arch Phys Med Rehabil , vol.42 , pp. 101-105
    • Liberson, W.T.1    Holmquest, H.J.2    Scott, D.3    Dow, M.4
  • 3
    • 0024554696 scopus 로고
    • Neural prosthetic interfaces with the nervous system
    • Loeb GE. Neural prosthetic interfaces with the nervous system. Trends Neurosci 1989;12:195-201.
    • (1989) Trends Neurosci , vol.12 , pp. 195-201
    • Loeb, G.E.1
  • 4
    • 0002821309 scopus 로고
    • Motor prostheses for restoration of upper extremity function
    • Stein RB, Peckham PH, Popovic DB, editors. New York: Oxford University Press
    • Peckham PH, Keith MW. Motor prostheses for restoration of upper extremity function. In: Stein RB, Peckham PH, Popovic DB, editors. Neural prostheses: replacing motor function after disease or disability. New York: Oxford University Press, 1992:162-87.
    • (1992) Neural Prostheses: Replacing Motor Function after Disease or Disability , pp. 162-187
    • Peckham, P.H.1    Keith, M.W.2
  • 5
    • 12644262646 scopus 로고
    • Peripheral nerve stimulation - Superficial and implanted
    • Fields WS, Leavitt LA, editors. New York: Intercontinental Book Corp
    • McNeal D. Peripheral nerve stimulation - superficial and implanted. In: Fields WS, Leavitt LA, editors. Neural organization and its relevance to prosthetics. New York: Intercontinental Book Corp, 1973:77-99.
    • (1973) Neural Organization and Its Relevance to Prosthetics , pp. 77-99
    • McNeal, D.1
  • 6
    • 0017161699 scopus 로고
    • Application of an implantable stimulator in the rehabilitation of paraplegic patients
    • Vavken E, Jeglic A. Application of an implantable stimulator in the rehabilitation of paraplegic patients. Int Surg 1976;61:335-43.
    • (1976) Int Surg , vol.61 , pp. 335-343
    • Vavken, E.1    Jeglic, A.2
  • 7
    • 0343088053 scopus 로고
    • Functional neurostimulation to substitute locomotion in paraplegia patients
    • Adrarde JD, editor. New York: VCH Publishers Inc
    • Thoma H, Frey M, Holle J, Kern H, Mayr W, Schwanda G, et al. Functional neurostimulation to substitute locomotion in paraplegia patients. In: Adrarde JD, editor. Artificial organs. New York: VCH Publishers Inc, 1987:515-29.
    • (1987) Artificial Organs , pp. 515-529
    • Thoma, H.1    Frey, M.2    Holle, J.3    Kern, H.4    Mayr, W.5    Schwanda, G.6
  • 8
    • 0014067894 scopus 로고
    • Control of a skeletal joint by electrical stimulation of antagonists
    • Vodovnik L, Crochetiere WJ, Reswick JB. Control of a skeletal joint by electrical stimulation of antagonists. Med Biol Eng 1967; 5:97-109.
    • (1967) Med Biol Eng , vol.5 , pp. 97-109
    • Vodovnik, L.1    Crochetiere, W.J.2    Reswick, J.B.3
  • 9
    • 0015787499 scopus 로고
    • Proportionally controlled functional electrical stimulation of hand
    • Rebersek S, Vodovnik L. Proportionally controlled functional electrical stimulation of hand. Arch Phys Med Rehabil 1973;54:378-82.
    • (1973) Arch Phys Med Rehabil , vol.54 , pp. 378-382
    • Rebersek, S.1    Vodovnik, L.2
  • 10
    • 0019133932 scopus 로고
    • Restoration of key grip and release in the C6 tetraplegic patient through functional electrical stimulation
    • Peckham PH, Marsolais EB, Mortimer JT. Restoration of key grip and release in the C6 tetraplegic patient through functional electrical stimulation. J Hand Surg 1980;5:462-9.
    • (1980) J Hand Surg , vol.5 , pp. 462-469
    • Peckham, P.H.1    Marsolais, E.B.2    Mortimer, J.T.3
  • 11
    • 0019596207 scopus 로고
    • Therapeutic effects of functional electrical stimulation of extremities
    • Vodovnik L. Therapeutic effects of functional electrical stimulation of extremities. Med Biol Eng Comput 1981;19:470-8.
    • (1981) Med Biol Eng Comput , vol.19 , pp. 470-478
    • Vodovnik, L.1
  • 12
  • 13
    • 0016675208 scopus 로고
    • Electrophysiological orthosis for the upper extremity in hemiplegia: Feasibility study
    • Merletti R, Acimovic R, Grobelnik S, Cvilak G. Electrophysiological orthosis for the upper extremity in hemiplegia: feasibility study. Arch Phys Med Rehabil 1975;56:507-13.
    • (1975) Arch Phys Med Rehabil , vol.56 , pp. 507-513
    • Merletti, R.1    Acimovic, R.2    Grobelnik, S.3    Cvilak, G.4
  • 14
    • 84978276070 scopus 로고
    • Treatment of hemiplegic upper extremity using electrical stimulation and bio-feedback training
    • Popovic D, editor. Belgrade: Yugoslav Committee for Electronics and Automation
    • Waters R, Bowman B, Baker L, Benton L, Meadows P. Treatment of hemiplegic upper extremity using electrical stimulation and bio-feedback training. In: Popovic D, editor. Advances in external control of human extremities 7. Belgrade: Yugoslav Committee for Electronics and Automation, 1981:251-66.
    • (1981) Advances in External Control of Human Extremities , vol.7 , pp. 251-266
    • Waters, R.1    Bowman, B.2    Baker, L.3    Benton, L.4    Meadows, P.5
  • 16
    • 0020632145 scopus 로고
    • Functional walking in paralysed patients by means of electrical stimulation
    • Marsolais EB, Kobetic R. Functional walking in paralysed patients by means of electrical stimulation. Clin Orthop Rel Res 1983; 175: 30-6.
    • (1983) Clin Orthop Rel Res , vol.175 , pp. 30-36
    • Marsolais, E.B.1    Kobetic, R.2
  • 17
    • 0023223730 scopus 로고
    • Functional electrical stimulation for walking in paraplegia
    • Marsolais EB, Kobetic R. Functional electrical stimulation for walking in paraplegia. J Bone Joint Surg 1987;69A:728-33.
    • (1987) J Bone Joint Surg , vol.69 A , pp. 728-733
    • Marsolais, E.B.1    Kobetic, R.2
  • 18
    • 0022749698 scopus 로고
    • Implantation techniques and experience with percutaneous intramuscular electrode in the lower extremities
    • Marsolais EB. Kobetic R. Implantation techniques and experience with percutaneous intramuscular electrode in the lower extremities. J Rehabil Res 1987;23:1-8.
    • (1987) J Rehabil Res , vol.23 , pp. 1-8
    • Marsolais, E.B.1    Kobetic, R.2
  • 20
    • 75549096986 scopus 로고
    • An electrophysiological splint for the hand
    • Long C, Masciarelli VD. An electrophysiological splint for the hand. Arch Phys Med Rehabil 1963;44:499-503.
    • (1963) Arch Phys Med Rehabil , vol.44 , pp. 499-503
    • Long, C.1    Masciarelli, V.D.2
  • 21
    • 0018580322 scopus 로고
    • Electrical stimulation of wrist and fingers for hemiplegic patients
    • Baker L, Yeh C, Wilson D, Waters RL. Electrical stimulation of wrist and fingers for hemiplegic patients. Phys Ther 1979;59:1495-9.
    • (1979) Phys Ther , vol.59 , pp. 1495-1499
    • Baker, L.1    Yeh, C.2    Wilson, D.3    Waters, R.L.4
  • 22
    • 0025254291 scopus 로고
    • Upper limb functions regained in quadriplegia: A hybrid computerized neuromuscular stimulation system
    • Nathan RH, Ohry A. Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system. Arch Phys Med Rehabil 1990;71:415-21.
    • (1990) Arch Phys Med Rehabil , vol.71 , pp. 415-421
    • Nathan, R.H.1    Ohry, A.2
  • 23
    • 0018654135 scopus 로고
    • Functional electrical stimulation of the upper limb: Charting the forearm surface
    • Nathan RH. Functional electrical stimulation of the upper limb: charting the forearm surface. Med Biol Eng Comput 1979;17:729-36.
    • (1979) Med Biol Eng Comput , vol.17 , pp. 729-736
    • Nathan, R.H.1
  • 26
    • 85030299923 scopus 로고
    • Multicentre trials of the Bionic Glove: Using electrical stimulation to improve hand closing and opening in people with spinal cord injury
    • June 25-30; Washington (DC): Washington, American Physical Therapy Association
    • Wieler M, Prochazka A, Kenwell Z, Gauthier M, Isaacson G. Multicentre trials of the Bionic Glove: using electrical stimulation to improve hand closing and opening in people with spinal cord injury. Proceedings of the 12th International Congress of World Confederation for Physical Therapy: 1995 June 25-30; Washington (DC): Washington, American Physical Therapy Association.
    • (1995) Proceedings of the 12th International Congress of World Confederation for Physical Therapy
    • Wieler, M.1    Prochazka, A.2    Kenwell, Z.3    Gauthier, M.4    Isaacson, G.5
  • 27
    • 0015156701 scopus 로고
    • Mammalian motor units: Physiological-histochemical correlation in three types in cat gastrocnemius
    • Burke RE, Levine DN, Zajac FC, Tsairis P, Engel WK. Mammalian motor units: physiological-histochemical correlation in three types in cat gastrocnemius. Science 1971;174:709-12.
    • (1971) Science , vol.174 , pp. 709-712
    • Burke, R.E.1    Levine, D.N.2    Zajac, F.C.3    Tsairis, P.4    Engel, W.K.5
  • 28
    • 0028297054 scopus 로고
    • Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesis
    • Wuolle KS, Van Doren CL, Thrope GB, Keith MW, Peckham PH. Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesis. J Hand Surg 1994;2:209-18.
    • (1994) J Hand Surg , vol.2 , pp. 209-218
    • Wuolle, K.S.1    Van Doren, C.L.2    Thrope, G.B.3    Keith, M.W.4    Peckham, P.H.5
  • 30
    • 84907040756 scopus 로고
    • The enigma of "carry-over"
    • Waters RL. The enigma of "carry-over." Int Rehabil Med 1984; 6:9-12.
    • (1984) Int Rehabil Med , vol.6 , pp. 9-12
    • Waters, R.L.1
  • 31
    • 0029325798 scopus 로고
    • Hand opening by electrical stimulation in patients with spastic hemiplegia
    • Hines AE, Crago PE, Billian C. Hand opening by electrical stimulation in patients with spastic hemiplegia. IEEE Trans Rehab Eng 1995;3:193-204.
    • (1995) IEEE Trans Rehab Eng , vol.3 , pp. 193-204
    • Hines, A.E.1    Crago, P.E.2    Billian, C.3
  • 32
    • 0026577290 scopus 로고
    • Attenuation of pathological tremors by functional electrical stimulation: II. Clinical application
    • Javidan M, Elek J, Prochazka A. Attenuation of pathological tremors by functional electrical stimulation: II. Clinical application. Ann Biomed Eng 1992;20:225-36.
    • (1992) Ann Biomed Eng , vol.20 , pp. 225-236
    • Javidan, M.1    Elek, J.2    Prochazka, A.3
  • 33
    • 0026506746 scopus 로고
    • Attenuation of pathological tremors by functional electrical stimulation: I. Technique
    • Prochazka A, Elek J, Javidan M. Attenuation of pathological tremors by functional electrical stimulation: I. Technique. Ann Biomed Eng 1992;20:205-24.
    • (1992) Ann Biomed Eng , vol.20 , pp. 205-224
    • Prochazka, A.1    Elek, J.2    Javidan, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.