Volumn 32, Issue 12, 2005, Pages 3636-3640

Determination of penumbral widths from ion chamber measurements

Author keywords

[No Author keywords available]

Indexed keywords

DECONVOLUTION;

EID: 33645001082     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2128086     Document Type: Article
Times cited : (17)

References (14)
  • 2
    • 0031911699 scopus 로고    scopus 로고
    • The use of deconvolution and total least squares in recovering a radiation detector line spread function
    • P. Charland, E. El-Khatib, and J. Wolters, " The use of deconvolution and total least squares in recovering a radiation detector line spread function, " Med. Phys. 25, 152-160 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 152-160
    • Charland, P.1
  • 3
    • 0037339773 scopus 로고    scopus 로고
    • The volume effect of detectors in the dosimetry of small fields used in IMRT
    • W. U. Laub and T. Wong, " The volume effect of detectors in the dosimetry of small fields used in IMRT, " Med. Phys. 30, 341-347 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 341-347
    • Laub, W.U.1
  • 4
    • 0031886274 scopus 로고    scopus 로고
    • Experimental determination of the convolution kernel for the study of the spatial response of a detector
    • F. Garcia-Vicente, J. M. Delgado, and C. Peraza, " Experimental determination of the convolution kernel for the study of the spatial response of a detector, " Med. Phys. 25, 202-207 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 202-207
    • Garcia-Vicente, F.1
  • 5
    • 0037152478 scopus 로고    scopus 로고
    • Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams
    • G. Bednarz, M. S. Huq, and U. F. Rosenow, " Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams, " Phys. Med. Biol. 47, 3643-3649 (2003).
    • (2003) Phys. Med. Biol. , vol.47 , pp. 3643-3649
    • Bednarz, G.1
  • 6
    • 0028799438 scopus 로고    scopus 로고
    • Deconvolution of detector size effect for small field measurement
    • P. Higgins, C. Sibata, L. Siskind, and J. W. Sohn, " Deconvolution of detector size effect for small field measurement, " Med. Phys. 23, 1663-1666 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1663-1666
    • Higgins, P.1
  • 7
    • 0021227635 scopus 로고
    • Analysis of physical parameters associated with the measurement of high-energy x-ray penumbra
    • D. J. Dawson, J. M. Harper, and A. C. Akinradewo, " Analysis of physical parameters associated with the measurement of high-energy x-ray penumbra, " Med. Phys. 11, 491-497 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 491-497
    • Dawson, D.J.1
  • 8
    • 0029818463 scopus 로고    scopus 로고
    • The effect of detector size to the broadening of the penumbra - A computer simulated study
    • K.-S. Chang, F.-F. Yin, and K.-W. Nie, " The effect of detector size to the broadening of the penumbra - A computer simulated study, " Med. Phys. 23, 1407-1411 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1407-1411
    • Chang, K.-S.1
  • 9
    • 0023887390 scopus 로고
    • Extraction of pencil beam kernels by the deconvolution method
    • C.-S. Chui and R. Mohan, " Extraction of pencil beam kernels by the deconvolution method, " Med. Phys. 15, 138-144 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 138-144
    • Chui, C.-S.1
  • 10
    • 0036852599 scopus 로고    scopus 로고
    • Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry
    • H.-R. Lee and M. Pankuch, J. C. Chu, J. J. Spokas, " Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry, " Med. Phys. 29, 2489 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2489
    • Lee, H.-R.1
  • 13
    • 85027234433 scopus 로고    scopus 로고
    • Computerized Radiation Scanners, Inc., 140 Sopwith Drive, Vero Beach, FL 32968.
    • Computerized Radiation Scanners, Inc., 140 Sopwith Drive, Vero Beach, FL 32968.
  • 14
    • 85027228763 scopus 로고    scopus 로고
    • Hinsdale Hospital, 120 N. Oak Street, Hinsdale, IL 60521.
    • Hinsdale Hospital, 120 N. Oak Street, Hinsdale, IL 60521.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.