메뉴 건너뛰기




Volumn 112, Issue 24, 2005, Pages 3763-3768

Registration of three-dimensional left atrial computed tomographic images with projection images obtained using fluoroscopy

Author keywords

Ablation; Atrium; Image guided therapy; Imaging; Registration

Indexed keywords

CONTRAST MEDIUM; PLATINUM;

EID: 33644874938     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/CIRCULATIONAHA.105.565218     Document Type: Article
Times cited : (73)

References (13)
  • 1
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659-666.
    • (1998) N Engl J Med , vol.339 , pp. 659-666
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3    Takahashi, A.4    Hocini, M.5    Quiniou, G.6
  • 2
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    • Chen SA, Hsieh MH, Tai CT, Tsai CF, Prakash VS, Yu WC, Hsu TL, Ding YA, Chang MS. Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. Circulation. 1999;100:1879-1886.
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3    Tsai, C.F.4    Prakash, V.S.5    Yu, W.C.6    Hsu, T.L.7    Ding, Y.A.8    Chang, M.S.9
  • 5
    • 0346786507 scopus 로고    scopus 로고
    • Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation
    • Lacomis JM, Wigginton W, Fuhrman C, Schwartzman D, Armfield DR, Pealer KM. Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation. Radiographics. 2003;23:S35-S50.
    • (2003) Radiographics , vol.23
    • Lacomis, J.M.1    Wigginton, W.2    Fuhrman, C.3    Schwartzman, D.4    Armfield, D.R.5    Pealer, K.M.6
  • 6
    • 19944428236 scopus 로고    scopus 로고
    • Feasibility and validation of registration of three-dimensional left atrial models derived from computed tomography with a noncontact cardiac mapping system
    • Sra J, Krum D, Hare J, Okerlund D, Thompson H, Vass M, Schweitzer J, Olson E, Foley WD, Akhtar M. Feasibility and validation of registration of three-dimensional left atrial models derived from computed tomography with a noncontact cardiac mapping system. Heart Rhythm. 2005;2:55-63.
    • (2005) Heart Rhythm , vol.2 , pp. 55-63
    • Sra, J.1    Krum, D.2    Hare, J.3    Okerlund, D.4    Thompson, H.5    Vass, M.6    Schweitzer, J.7    Olson, E.8    Foley, W.D.9    Akhtar, M.10
  • 7
    • 0000988974 scopus 로고
    • A generalized solution of the orthogonal Procrustes problem
    • Schönemann PH. A generalized solution of the orthogonal Procrustes problem. Psychometrika. 1966;31:1-10.
    • (1966) Psychometrika , vol.31 , pp. 1-10
    • Schönemann, P.H.1
  • 11
    • 0034546682 scopus 로고    scopus 로고
    • Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: A comparison of two image registration methods
    • Solomon SB, White P, Wiener CM, Orens JB, Wang KP. Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: a comparison of two image registration methods. Chest. 2000;118:1783-1787.
    • (2000) Chest , vol.118 , pp. 1783-1787
    • Solomon, S.B.1    White, P.2    Wiener, C.M.3    Orens, J.B.4    Wang, K.P.5
  • 12
    • 9644265416 scopus 로고    scopus 로고
    • Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation: Feasibility in a porcine model of healed myocardial infarction
    • Reddy VY, Malchano ZJ, Holmvang G, Schmidt EJ, d'Avila A, Houghtaling C, Chan RC, Ruskin JN. Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation: feasibility in a porcine model of healed myocardial infarction. J Am Coll Cardiol. 2004;44:2202-2213.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2202-2213
    • Reddy, V.Y.1    Malchano, Z.J.2    Holmvang, G.3    Schmidt, E.J.4    D'Avila, A.5    Houghtaling, C.6    Chan, R.C.7    Ruskin, J.N.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.