메뉴 건너뛰기




Volumn 14, Issue 1, 2006, Pages 77-88

3T MR imaging of the brain

Author keywords

[No Author keywords available]

Indexed keywords

ACCELERATION; ARTICLE; BRAIN; DIFFUSION; HUMAN; MAGNETIC RESONANCE ANGIOGRAPHY; MULTIPLE SCLEROSIS; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; ORBIT; SKULL BASE;

EID: 33644841484     PISSN: 10649689     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mric.2006.01.004     Document Type: Review
Times cited : (19)

References (26)
  • 1
    • 32944469372 scopus 로고    scopus 로고
    • Advantages and pitfalls in 3T MR brain imaging: A pictorial review
    • B.L. Schmitz, A.J. Aschoff, and M.H. Hoffmann Advantages and pitfalls in 3T MR brain imaging: a pictorial review AJNR Am J Neuroradiol 26 2005 2229 2237
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 2229-2237
    • Schmitz, B.L.1    Aschoff, A.J.2    Hoffmann, M.H.3
  • 2
    • 1242294355 scopus 로고    scopus 로고
    • The high-field-strength curmudgeon
    • J.S. Ross The high-field-strength curmudgeon AJNR Am J Neuroradiol 25 2004 168 169
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 168-169
    • Ross, J.S.1
  • 3
    • 0345167988 scopus 로고    scopus 로고
    • Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla
    • T. Ethofer, I. Mader, and U. Seeger Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1.5 and 3 Tesla Magn Reson Med 50 2003 1296 1301
    • (2003) Magn Reson Med , vol.50 , pp. 1296-1301
    • Ethofer, T.1    Mader, I.2    Seeger, U.3
  • 4
    • 0001881418 scopus 로고    scopus 로고
    • Image contrast and noise
    • D.D. Stark W.G. Bradley 3rd edition Mosby St. Louis (MO)
    • R.E. Hendrick Image contrast and noise D.D. Stark W.G. Bradley Magnetic resonance imaging, vol. 1 3rd edition 1999 Mosby St. Louis (MO) 43 67
    • (1999) Magnetic Resonance Imaging, Vol. 1 , pp. 43-67
    • Hendrick, R.E.1
  • 5
    • 0034759242 scopus 로고    scopus 로고
    • Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
    • J.G. Sled, and G.B. Pike Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI Magn Reson Med 46 2001 923 931
    • (2001) Magn Reson Med , vol.46 , pp. 923-931
    • Sled, J.G.1    Pike, G.B.2
  • 6
    • 24144448806 scopus 로고    scopus 로고
    • T1, T2 relaxation and magnetization transfer in tissue at 3T
    • G.J. Stanisz, E.E. Odrobina, and J. Pun T1, T2 relaxation and magnetization transfer in tissue at 3T Magn Reson Med 54 2005 507 512
    • (2005) Magn Reson Med , vol.54 , pp. 507-512
    • Stanisz, G.J.1    Odrobina, E.E.2    Pun, J.3
  • 8
    • 0024573913 scopus 로고
    • Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
    • S.D. Wolff, and R.S. Balaban Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo Magn Reson Med 10 1989 135 144
    • (1989) Magn Reson Med , vol.10 , pp. 135-144
    • Wolff, S.D.1    Balaban, R.S.2
  • 9
    • 32944469184 scopus 로고    scopus 로고
    • Enhancing gray-to-white matter contrast in 3T T1 spin-echo brain scans by optimizing flip angle
    • B.L. Schmitz, G. Gron, and F. Brausewetter Enhancing gray-to-white matter contrast in 3T T1 spin-echo brain scans by optimizing flip angle AJNR Am J Neuroradiol 26 2005 2000 2004
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 2000-2004
    • Schmitz, B.L.1    Gron, G.2    Brausewetter, F.3
  • 10
    • 27744558426 scopus 로고    scopus 로고
    • Brain tumors: Full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T - Initial experience
    • C. Krautmacher, W.A. Willinek, and H.J. Tschampa Brain tumors: full- and half-dose contrast-enhanced MR imaging at 3.0 T compared with 1.5 T - initial experience Radiology 237 2005 1014 1019
    • (2005) Radiology , vol.237 , pp. 1014-1019
    • Krautmacher, C.1    Willinek, W.A.2    Tschampa, H.J.3
  • 11
    • 0030280548 scopus 로고    scopus 로고
    • Multislice T1-weighted hybrid RARE in CNS imaging: Assessment of magnetization transfer effects and artifacts
    • E.R. Melhem, H. Jara, and E.K. Yucel Multislice T1-weighted hybrid RARE in CNS imaging: assessment of magnetization transfer effects and artifacts J Magn Reson Imaging 6 1996 903 908
    • (1996) J Magn Reson Imaging , vol.6 , pp. 903-908
    • Melhem, E.R.1    Jara, H.2    Yucel, E.K.3
  • 12
    • 0026562978 scopus 로고
    • Magnetization transfer effects in multislice RARE sequences
    • P.S. Melki, and R.V. Mulkern Magnetization transfer effects in multislice RARE sequences Magn Reson Med 24 1992 189 195
    • (1992) Magn Reson Med , vol.24 , pp. 189-195
    • Melki, P.S.1    Mulkern, R.V.2
  • 13
    • 0028157387 scopus 로고
    • Cranial tissues: Appearance at gadolinium-enhanced and nonenhanced MR imaging with magnetization transfer contrast
    • A.D. Elster, J.C. King, and V.P. Mathews Cranial tissues: appearance at gadolinium-enhanced and nonenhanced MR imaging with magnetization transfer contrast Radiology 190 1994 541 546
    • (1994) Radiology , vol.190 , pp. 541-546
    • Elster, A.D.1    King, J.C.2    Mathews, V.P.3
  • 14
    • 0028330776 scopus 로고
    • Improved detection of gadolinium enhancement using magnetization transfer imaging
    • A.D. Elster, V.P. Mathews, and J.C. King Improved detection of gadolinium enhancement using magnetization transfer imaging Neuroimaging Clin N Am 4 1994 185 192
    • (1994) Neuroimaging Clin N Am , vol.4 , pp. 185-192
    • Elster, A.D.1    Mathews, V.P.2    King, J.C.3
  • 15
    • 0027968745 scopus 로고
    • Magnetization transfer imaging: Practical aspects and clinical applications
    • S.D. Wolff, and R.S. Balaban Magnetization transfer imaging: practical aspects and clinical applications Radiology 192 1994 593 599
    • (1994) Radiology , vol.192 , pp. 593-599
    • Wolff, S.D.1    Balaban, R.S.2
  • 16
    • 0032880622 scopus 로고    scopus 로고
    • Magnetization transfer imaging of the brain: A quantitative comparison of results obtained at 1.5 and 4.0 T
    • U. Duvvuri, D.A. Roberts, and J.S. Leigh Magnetization transfer imaging of the brain: a quantitative comparison of results obtained at 1.5 and 4.0 T J Magn Reson Imaging 10 1999 527 532
    • (1999) J Magn Reson Imaging , vol.10 , pp. 527-532
    • Duvvuri, U.1    Roberts, D.A.2    Leigh, J.S.3
  • 17
    • 13844266851 scopus 로고    scopus 로고
    • Functional 3.0-T MR assessment of higher cognitive function: Are there advantages over 1.5-T imaging?
    • K. Hoenig, C.K. Kuhl, and L. Scheef Functional 3.0-T MR assessment of higher cognitive function: are there advantages over 1.5-T imaging? Radiology 234 2005 860 868
    • (2005) Radiology , vol.234 , pp. 860-868
    • Hoenig, K.1    Kuhl, C.K.2    Scheef, L.3
  • 18
    • 0033067313 scopus 로고    scopus 로고
    • Clinical rationale for very-high-field (3.0 Tesla) functional magnetic resonance imaging
    • K.R. Thulborn Clinical rationale for very-high-field (3.0 Tesla) functional magnetic resonance imaging Top Magn Reson Imaging 10 1999 37 50
    • (1999) Top Magn Reson Imaging , vol.10 , pp. 37-50
    • Thulborn, K.R.1
  • 19
    • 0031723433 scopus 로고    scopus 로고
    • Usefulness of optimized gadolinium-enhanced fast fluid-attenuated inversion recovery MR imaging in revealing lesions of the brain
    • E.R. Melhem, R.J. Bert, and R.E. Walker Usefulness of optimized gadolinium-enhanced fast fluid-attenuated inversion recovery MR imaging in revealing lesions of the brain AJR Am J Roentgenol 171 1998 803 807
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 803-807
    • Melhem, E.R.1    Bert, R.J.2    Walker, R.E.3
  • 20
    • 0033073691 scopus 로고    scopus 로고
    • Why neuroradiologists should consider very-high-field magnets for clinical applications of functional magnetic resonance imaging
    • K.R. Thulborn Why neuroradiologists should consider very-high-field magnets for clinical applications of functional magnetic resonance imaging Top Magn Reson Imaging 10 1999 1 2
    • (1999) Top Magn Reson Imaging , vol.10 , pp. 1-2
    • Thulborn, K.R.1
  • 21
    • 11144322057 scopus 로고    scopus 로고
    • Structural abnormalities remote from the seizure focus: A study using T2 relaxometry at 3 T
    • R.S. Briellmann, G.D. Jackson, and G.S. Pell Structural abnormalities remote from the seizure focus: a study using T2 relaxometry at 3 T Neurology 63 2004 2303 2308
    • (2004) Neurology , vol.63 , pp. 2303-2308
    • Briellmann, R.S.1    Jackson, G.D.2    Pell, G.S.3
  • 22
    • 0034868687 scopus 로고    scopus 로고
    • PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion
    • K.P. Forbes, J.G. Pipe, and C.R. Bird PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion J Magn Reson Imaging 14 2001 215 222
    • (2001) J Magn Reson Imaging , vol.14 , pp. 215-222
    • Forbes, K.P.1    Pipe, J.G.2    Bird, C.R.3
  • 23
    • 0036829562 scopus 로고    scopus 로고
    • Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging
    • K.P. Forbes, J.G. Pipe, and J.P. Karis Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging Radiology 225 2002 551 555
    • (2002) Radiology , vol.225 , pp. 551-555
    • Forbes, K.P.1    Pipe, J.G.2    Karis, J.P.3
  • 24
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • J.G. Pipe Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging Magn Reson Med 42 1999 963 969
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 25
    • 12744261213 scopus 로고    scopus 로고
    • 3.0-Tesla MR angiography of intracranial aneurysms: Comparison of time-of-flight and contrast-enhanced techniques
    • G.F. Gibbs, J. Huston III, and M.A. Bernstein 3.0-Tesla MR angiography of intracranial aneurysms: comparison of time-of-flight and contrast-enhanced techniques J Magn Reson Imaging 21 2005 97 102
    • (2005) J Magn Reson Imaging , vol.21 , pp. 97-102
    • Gibbs, G.F.1    Huston III, J.2    Bernstein, M.A.3
  • 26
    • 1642541669 scopus 로고    scopus 로고
    • Improved image quality of intracranial aneurysms: 3.0-T versus 1.5 T time-of-flight MR angiography
    • G.F. Gibbs, J. Huston III, and M.A. Bernstein Improved image quality of intracranial aneurysms: 3.0-T versus 1.5 T time-of-flight MR angiography AJNR Am J Neuroradiol 25 2004 84 87
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 84-87
    • Gibbs, G.F.1    Huston III, J.2    Bernstein, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.