-
1
-
-
0036267213
-
Comparability of proptosis measurements by different techniques
-
Segni M, Bartley GB, Garrity JA et al . Comparability of proptosis measurements by different techniques. Am J Ophthalmol 2002;133:813-8.
-
(2002)
Am J Ophthalmol
, vol.133
, pp. 813-818
-
-
Segni, M.1
Bartley, G.B.2
Garrity, J.A.3
-
2
-
-
0034988771
-
Normal range of exophthalmos values on orbit computerized tomography in Koreans
-
Kim IT, Choi JB. Normal range of exophthalmos values on orbit computerized tomography in Koreans. Ophthalmologica 2001;215:156-62.
-
(2001)
Ophthalmologica
, vol.215
, pp. 156-162
-
-
Kim, I.T.1
Choi, J.B.2
-
3
-
-
0000354767
-
Ein einfaches Exophthalmometer
-
Hertel E. Ein einfaches Exophthalmometer. Arch Ophthalmol 1905;60:171-4.
-
(1905)
Arch Ophthalmol
, vol.60
, pp. 171-174
-
-
Hertel, E.1
-
4
-
-
0030842685
-
Exophthalmometry: A comparative study of Naugle and Hertel instruments
-
Cole HP, Couvillion JT, Fink AJ, et al Exophthalmometry: a comparative study of Naugle and Hertel instruments. Ophthal Plast Reconstr Surg 1997;13:189-94.
-
(1997)
Ophthal Plast Reconstr Surg
, vol.13
, pp. 189-194
-
-
Cole, H.P.1
Couvillion, J.T.2
Fink, A.J.3
-
5
-
-
0028245422
-
Hertel exophthalmometry without orbital rim contact
-
Kratky V, Hurwitz JJ. Hertel exophthalmometry without orbital rim contact. Ophthalmology 1994;101:931-7.
-
(1994)
Ophthalmology
, vol.101
, pp. 931-937
-
-
Kratky, V.1
Hurwitz, J.J.2
-
6
-
-
0036021127
-
Interinstrument variability in Hertel-type exophthalmometers
-
Sleep T, Manners R. Interinstrument variability in Hertel-type exophthalmometers. Ophthal Plast Reconstr Surg 2002;18:254-7.
-
(2002)
Ophthal Plast Reconstr Surg
, vol.18
, pp. 254-257
-
-
Sleep, T.1
Manners, R.2
-
7
-
-
6344234932
-
Normal exophthalmometry values: The need for calibrated exophthalmometers
-
[Editorial]
-
Van den Bosch WA. Normal exophthalmometry values: the need for calibrated exophthalmometers [Editorial]. Orbit 2004;23:147-51.
-
(2004)
Orbit
, vol.23
, pp. 147-151
-
-
Van Den Bosch, W.A.1
-
8
-
-
6344247585
-
Reliability exophthalmos measurement and exophthalmometry value distribution in a healthy Dutch population and graves patients: An exploring study
-
Mourits MP, Lombardo SHC, Van der Sluijs FA, Fenton S. Reliability exophthalmos measurement and exophthalmometry value distribution in a healthy Dutch population and graves patients: an exploring study. Orbit 2004;23:161-8.
-
(2004)
Orbit
, vol.23
, pp. 161-168
-
-
Mourits, M.P.1
Lombardo, S.H.C.2
Van Der Sluijs, F.A.3
Fenton, S.4
-
9
-
-
0014899490
-
Principles and sources of error in exophthalmometry: A new exophthalmometer
-
Davanger M. Principles and sources of error in exophthalmometry: a new exophthalmometer. Acta Ophthalmol 1970;48:625-33.
-
(1970)
Acta Ophthalmol
, vol.48
, pp. 625-633
-
-
Davanger, M.1
-
11
-
-
0021930088
-
Positional effects on exophthalmometer readings in Graves disease
-
Frueh BR, Garber F, Gril RL, et al Positional effects on exophthalmometer readings in Graves disease. Arch Ophthalmol 1985;103: 1355-6.
-
(1985)
Arch Ophthalmol
, vol.103
, pp. 1355-1356
-
-
Frueh, B.R.1
Garber, F.2
Gril, R.L.3
|