메뉴 건너뛰기




Volumn 55, Issue 3, 2006, Pages 465-471

Fast low-angle dual spin-echo (FLADE): A new robust pulse sequence for structural imaging of trabecular bone

Author keywords

Double spin echo; FLADE; FLASE; High resolution imaging; Trabecular bone

Indexed keywords

MAGNETIC SUSCEPTIBILITY; MAGNETIZATION REVERSAL; OPTICAL TRANSFER FUNCTION;

EID: 33644802947     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.20789     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 0022406116 scopus 로고
    • The role of three-dimensional trabecular microstructure in the pathogenesis of vertebral compression fractures
    • Kleerekoper M, Villanueva AR, Stanciu J, Sudhaker Rao D, Parfitt AM. The role of three-dimensional trabecular microstructure in the pathogenesis of vertebral compression fractures. Calcif Tissue Int 1985;37:594-597.
    • (1985) Calcif Tissue Int , vol.37 , pp. 594-597
    • Kleerekoper, M.1    Villanueva, A.R.2    Stanciu, J.3    Sudhaker Rao, D.4    Parfitt, A.M.5
  • 2
    • 0027293872 scopus 로고
    • Architecture and vertebral fracture
    • Recker RR. Architecture and vertebral fracture. Calcif Tissue Int 1993;53 Suppl 1:S139-142.
    • (1993) Calcif Tissue Int , vol.53 , Issue.SUPPL. 1
    • Recker, R.R.1
  • 3
    • 0034765125 scopus 로고    scopus 로고
    • Bone microarchitecture and bone fragility in men: DXA and histomorphometry in humans and in the orchidectomized rat model
    • Audran M, Chappard D, Legrand E, Libouban H, Basle MF. Bone microarchitecture and bone fragility in men: DXA and histomorphometry in humans and in the orchidectomized rat model. Calcif Tissue Int 2001;69:214-217.
    • (2001) Calcif Tissue Int , vol.69 , pp. 214-217
    • Audran, M.1    Chappard, D.2    Legrand, E.3    Libouban, H.4    Basle, M.F.5
  • 5
    • 0036815594 scopus 로고    scopus 로고
    • Magnetic resonance imaging of trabecular bone structure
    • Majumdar S. Magnetic resonance imaging of trabecular bone structure. Top Magn Reson Imaging 2002;13:323-334.
    • (2002) Top Magn Reson Imaging , vol.13 , pp. 323-334
    • Majumdar, S.1
  • 6
    • 3042737563 scopus 로고    scopus 로고
    • Noninvasive assessment of bone architecture by magnetic resonance micro-imaging-based virtual bone biopsy
    • Wehrli FW, Saha PK, Gomberg BR, Song HK. Noninvasive assessment of bone architecture by magnetic resonance micro-imaging-based virtual bone biopsy. Proc IEEE 2003;91:1520-1542.
    • (2003) Proc IEEE , vol.91 , pp. 1520-1542
    • Wehrli, F.W.1    Saha, P.K.2    Gomberg, B.R.3    Song, H.K.4
  • 7
    • 0034922577 scopus 로고    scopus 로고
    • Digital topological analysis of in vivo magnetic resonance microimages of trabecular bone reveals structural implications of osteoporosis
    • Wehrli FW, Gomberg BR, Saha PK, Song HK, Hwang SN, Snyder PJ. Digital topological analysis of in vivo magnetic resonance microimages of trabecular bone reveals structural implications of osteoporosis. J Bone Miner Res 2001;16:1520-1531.
    • (2001) J Bone Miner Res , vol.16 , pp. 1520-1531
    • Wehrli, F.W.1    Gomberg, B.R.2    Saha, P.K.3    Song, H.K.4    Hwang, S.N.5    Snyder, P.J.6
  • 8
    • 0037950421 scopus 로고    scopus 로고
    • Trabecular bone structure of the calcaneus: Preliminary in vivo MR imaging assessment in men with osteoporosis
    • Boutry N, Cortet B, Dubois P, Marchandise X, Cotten A. Trabecular bone structure of the calcaneus: preliminary in vivo MR imaging assessment in men with osteoporosis. Radiology 2003;227:708-717.
    • (2003) Radiology , vol.227 , pp. 708-717
    • Boutry, N.1    Cortet, B.2    Dubois, P.3    Marchandise, X.4    Cotten, A.5
  • 9
    • 0036146823 scopus 로고    scopus 로고
    • High-resolution MRI and micro-FE for the evaluation of changes in bone mechanical properties during longitudinal clinical trials: Application to calcaneal bone in postmenopausal women after one year of idoxifene treatment
    • van Rietbergen B, Majumdar S, Newitt D, MacDonald B. High-resolution MRI and micro-FE for the evaluation of changes in bone mechanical properties during longitudinal clinical trials: application to calcaneal bone in postmenopausal women after one year of idoxifene treatment. Clin Biomech (Bristol, Avon) 2002;17:81-88.
    • (2002) Clin Biomech (Bristol, Avon) , vol.17 , pp. 81-88
    • Van Rietbergen, B.1    Majumdar, S.2    Newitt, D.3    MacDonald, B.4
  • 11
    • 0030909915 scopus 로고    scopus 로고
    • Magnetic susceptibility measurement of insoluble solids by NMR: Magnetic susceptibility of bone
    • Hopkins JA, Wehrli FW. Magnetic susceptibility measurement of insoluble solids by NMR: magnetic susceptibility of bone. Magn Reson Med 1997;37:494-500.
    • (1997) Magn Reson Med , vol.37 , pp. 494-500
    • Hopkins, J.A.1    Wehrli, F.W.2
  • 12
    • 0027413855 scopus 로고
    • High-resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo
    • Jara H, Wehrli FW, Chung H. High-resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo. Magn Reson Med 1993;29:528-539.
    • (1993) Magn Reson Med , vol.29 , pp. 528-539
    • Jara, H.1    Wehrli, F.W.2    Chung, H.3
  • 13
    • 0029894505 scopus 로고    scopus 로고
    • Fast 3D large-angle spin-echo imaging (3D FLASE)
    • Ma J, Wehrli FW, Song HK. Fast 3D large-angle spin-echo imaging (3D FLASE). Magn Reson Med 1996;35:903-910.
    • (1996) Magn Reson Med , vol.35 , pp. 903-910
    • Ma, J.1    Wehrli, F.W.2    Song, H.K.3
  • 14
    • 3543121914 scopus 로고    scopus 로고
    • Coherence induced artifacts in large-flip-angle steady-state spin-echo imaging
    • Vasilic B, Song H, Wehrli F. Coherence induced artifacts in large-flip-angle steady-state spin-echo imaging. Magn Reson Med 2004;52:346-353.
    • (2004) Magn Reson Med , vol.52 , pp. 346-353
    • Vasilic, B.1    Song, H.2    Wehrli, F.3
  • 15
    • 0023939889 scopus 로고
    • Correction of spatially dependent phase shifts for partial Fourier imaging
    • MacFall JR, Pelc NJ, Vavrek RM. Correction of spatially dependent phase shifts for partial Fourier imaging. Magn Reson Imaging 1988;6:143-155.
    • (1988) Magn Reson Imaging , vol.6 , pp. 143-155
    • MacFall, J.R.1    Pelc, N.J.2    Vavrek, R.M.3
  • 16
    • 0033623975 scopus 로고    scopus 로고
    • Application of topological analysis to magnetic resonance images of human trabecular bone
    • Gomberg BG, Saha PK, Song HK, Hwang SN, Wehrli FW. Application of topological analysis to magnetic resonance images of human trabecular bone. IEEE Trans Med Im 2000;19:166-174.
    • (2000) IEEE Trans Med Im , vol.19 , pp. 166-174
    • Gomberg, B.G.1    Saha, P.K.2    Song, H.K.3    Hwang, S.N.4    Wehrli, F.W.5
  • 17
    • 0030229278 scopus 로고    scopus 로고
    • Noise in MRI
    • Macovski A. Noise in MRI. Magn Reson Med 36:494-497, 1996.
    • (1996) Magn Reson Med , vol.36 , pp. 494-497
    • Macovski, A.1
  • 18
    • 0036233788 scopus 로고    scopus 로고
    • Subvoxel processing: A method for reducing partial volume blurring with application to in vivo MR images of trabecular bone
    • Hwang SN, Wehrli FW. Subvoxel processing: a method for reducing partial volume blurring with application to in vivo MR images of trabecular bone. Magn Reson Med 2002;47:948-957.
    • (2002) Magn Reson Med , vol.47 , pp. 948-957
    • Hwang, S.N.1    Wehrli, F.W.2
  • 19
    • 0026836513 scopus 로고
    • In vivo relationship between marrow T2* and trabecular bone density determined with a chemical shift-selective asymmetric spin-echo sequence
    • Majumdar S, Genant HK. In vivo relationship between marrow T2* and trabecular bone density determined with a chemical shift-selective asymmetric spin-echo sequence. J Magn Reson Imaging 1992;2:209-219.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 209-219
    • Majumdar, S.1    Genant, H.K.2
  • 20
    • 0033735617 scopus 로고    scopus 로고
    • Cross-sectional study of osteopenia by quantitative magnetic resonance and bone densitometry
    • Wehrli FW, Hopkins JA, Hwang SN, Song HK, Snyder PJ, Haddad JG. Cross-sectional study of osteopenia by quantitative magnetic resonance and bone densitometry. Radiology 2000;217:527-538.
    • (2000) Radiology , vol.217 , pp. 527-538
    • Wehrli, F.W.1    Hopkins, J.A.2    Hwang, S.N.3    Song, H.K.4    Snyder, P.J.5    Haddad, J.G.6
  • 21
    • 0033155708 scopus 로고    scopus 로고
    • Experimental evaluation of a surface charge method for computing the induced magnetic field in trabecular bone
    • Hwang SN, Wehrli FW. Experimental evaluation of a surface charge method for computing the induced magnetic field in trabecular bone. J Magn Reson 1999;139:35-45.
    • (1999) J Magn Reson , vol.139 , pp. 35-45
    • Hwang, S.N.1    Wehrli, F.W.2
  • 22
    • 20044386323 scopus 로고    scopus 로고
    • Application of refocused steady-state free-precession methods at 1.5 and 3 T to in vivo high-resolution MRI of trabecular bone: Simulations and experiments
    • Banerjee S, Han ET, Krug R, Newitt DC, Majumdar S. Application of refocused steady-state free-precession methods at 1.5 and 3 T to in vivo high-resolution MRI of trabecular bone: simulations and experiments. J Magn Reson Imaging 2005;21:818-825.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 818-825
    • Banerjee, S.1    Han, E.T.2    Krug, R.3    Newitt, D.C.4    Majumdar, S.5
  • 23
    • 27644439963 scopus 로고    scopus 로고
    • Implications of pulse sequence in structural imaging of trabecular bone
    • Techawiboonwong A, Song H, Saha P, Wehrli F. Implications of pulse sequence in structural imaging of trabecular bone. J Magn Reson Imaging 2005;22:647-655.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 647-655
    • Techawiboonwong, A.1    Song, H.2    Saha, P.3    Wehrli, F.4
  • 25
    • 0344689909 scopus 로고    scopus 로고
    • In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis
    • Song HK, Wehrli FW. In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis. Magn Reson Med 1999;41:947-953.
    • (1999) Magn Reson Med , vol.41 , pp. 947-953
    • Song, H.K.1    Wehrli, F.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.