High pacing impedances: Are you overtorquing your leads?

Author keywords

Atrium; Electrophysiology; Endocardium; Impedance; Pacing

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; CONTROLLED STUDY; ELECTROCARDIOGRAPHY; ELECTROPHYSIOLOGY; ENDOCARDIUM; ENDOSCOPY; HEART ATRIUM MUSCLE; HEART ATRIUM PACING; HEART RIGHT ATRIUM; HUMAN; HUMAN TISSUE; IMPEDANCE; NONHUMAN; P WAVE; PACEMAKER ELECTRODE; PARAMETER; SWINE; TORQUE; ANIMAL; ARTIFICIAL HEART PACEMAKER; ELECTRODE; EQUIPMENT DESIGN; HEART PACING; IN VITRO STUDY; METHODOLOGY; STANDARD;

EID: 33644693962     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2005.00192.x     Document Type: Article
Times cited : (18)

References (15)
  • 2
    • 0018888570 scopus 로고
    • Measurement of the ohmic electrode-tissue contact resistance and the voltage applied to myocardium
    • Benzing G, III., Iltis R, Helmsworth JA, Schreiber T, Kaplan S. Measurement of the ohmic electrode-tissue contact resistance and the voltage applied to myocardium. J Biomed Eng 1980 2 : 3 8.
    • (1980) J Biomed Eng , vol.2 , pp. 3-8
    • Benzing, G.1    Iii2    Iltis, R.3    Helmsworth, J.A.4    Schreiber, T.5    Kaplan, S.6
  • 3
    • 0029741132 scopus 로고    scopus 로고
    • Low stimulation impedance in pacemaker patients with cardiac diseases. the Thera Pacemaker Study Group
    • Schuchert A, van Langen H, Michels K, Meinertz T. Low stimulation impedance in pacemaker patients with cardiac diseases. The Thera Pacemaker Study Group. Dtsch Med Wochenschr 1996 121 : 1046 1049.
    • (1996) Dtsch Med Wochenschr , vol.121 , pp. 1046-1049
    • Schuchert, A.1    Van Langen, H.2    Michels, K.3    Meinertz, T.4
  • 4
    • 0031654637 scopus 로고    scopus 로고
    • Changes in pacing lead impedance over time predict lead failure
    • Sharif MN, Wyse DG, Rothschild JM, Gillis AM. Changes in pacing lead impedance over time predict lead failure. Am J Cardiol 1998 82 : 600 603.
    • (1998) Am J Cardiol , vol.82 , pp. 600-603
    • Sharif, M.N.1    Wyse, D.G.2    Rothschild, J.M.3    Gillis, A.M.4
  • 5
    • 0021264636 scopus 로고
    • Insulation failure with bipolar polyurethane pacing leads
    • Raymond RD, Nanian KB. Insulation failure with bipolar polyurethane pacing leads. PACE 1984 7 : 378 380.
    • (1984) PACE , vol.7 , pp. 378-380
    • Raymond, R.D.1    Nanian, K.B.2
  • 6
    • 0029978858 scopus 로고    scopus 로고
    • Effects of high energy shocks on pacing impedance during transvenous ICD implantation
    • Hidden-Lucet F, Hartung WM, McTeague KK, Walter PF, Langberg JJ. Effects of high energy shocks on pacing impedance during transvenous ICD implantation. PACE 1996 19 : 752 757.
    • (1996) PACE , vol.19 , pp. 752-757
    • Hidden-Lucet, F.1    Hartung, W.M.2    McTeague, K.K.3    Walter, P.F.4    Langberg, J.J.5
  • 7
    • 0022979946 scopus 로고
    • Time course of transvenous pacemaker stimulation impedance, capture threshold, and electrogram amplitude
    • Platia EV, Brinker JA. Time course of transvenous pacemaker stimulation impedance, capture threshold, and electrogram amplitude. PACE 1986 9 : 620 625.
    • (1986) PACE , vol.9 , pp. 620-625
    • Platia, E.V.1    Brinker, J.A.2
  • 8
    • 0027435171 scopus 로고
    • Effects of local steroid elution on chronic pacing threshold and impedance of endocardial pacemaker leads
    • Schuchert A, Kuck KH. Effects of local steroid elution on chronic pacing threshold and impedance of endocardial pacemaker leads. Cardiology 1993 83 : 240 243.
    • (1993) Cardiology , vol.83 , pp. 240-243
    • Schuchert, A.1    Kuck, K.H.2
  • 10
    • 0029919690 scopus 로고    scopus 로고
    • Reliability and variability of impedance measured by real-time telemetry
    • Schuchert A, Cappato R, Kuck KH, Meinertz T. Reliability and variability of impedance measured by real-time telemetry. PACE 1996 19 : 265 271.
    • (1996) PACE , vol.19 , pp. 265-271
    • Schuchert, A.1    Cappato, R.2    Kuck, K.H.3    Meinertz, T.4
  • 11
    • 0031878214 scopus 로고    scopus 로고
    • Pacing impedance variability in tined steroid eluting leads
    • Danilovic D, Ohm OJ. Pacing impedance variability in tined steroid eluting leads. PACE 1998 21 : 1356 1363.
    • (1998) PACE , vol.21 , pp. 1356-1363
    • Danilovic, D.1    Ohm, O.J.2
  • 12
    • 0002944687 scopus 로고
    • Stimulation electrodes
    • In: Schaldach, M., Furman, S., Hein, F., Thull, R. (. eds.). Berlin, Heidelberg, Springer-Valley Publishing
    • Irnich W. Stimulation electrodes. In : Schaldach M, Furman S, Hein F, Thull R (eds.) Advances in Pacemaker Technology. Berlin, Heidelberg, Springer-Valley Publishing, 1975, 247 253.
    • (1975) Advances in Pacemaker Technology. , pp. 247-253
    • Irnich, W.1
  • 15
    • 0036906732 scopus 로고    scopus 로고
    • Comparative in vivo and ex vivo pacing and sensing performance study using an isolated four-chamber working swine heart model. [abstract]
    • Laske TG, Skadsberg ND, Iaizzo PA. Comparative in vivo and ex vivo pacing and sensing performance study using an isolated four-chamber working swine heart model. [Abstract] IEEE Trans 2002 A.6.1 : 4 3.
    • (2002) IEEE Trans , vol.61 , pp. 4-3
    • Laske, T.G.1    Skadsberg, N.D.2    Iaizzo, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.