Impedance of pacemaker leads: Correlation of different methods

Author keywords

lead impedance; pacing system analyzer; polarization effect

Indexed keywords

ADULT; ANALYTIC METHOD; ARTICLE; ARTIFICIAL HEART PACEMAKER; HEART MUSCLE CELL; HEART PACING; HUMAN; IMPEDANCE; IMPLANTATION; MAJOR CLINICAL STUDY; POLARIZATION; STATISTICAL ANALYSIS; TELEMETRY;

EID: 0030042857     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb04795.x     Document Type: Article
Times cited : (9)

References (9)
  • 1
    • 0019596453 scopus 로고
    • Stimulation and sensing thresholds for cardiac pacing: Electrophysiologic and technical aspects
    • Barold SS, Ong LS, Heinle RA. Stimulation and sensing thresholds for cardiac pacing: Electrophysiologic and technical aspects. Prog Cardiovasc Dis 1981; 24:1-24.
    • (1981) Prog Cardiovasc Dis , vol.24 , pp. 1-24
    • Barold, S.S.1    Ong, L.S.2    Heinle, R.A.3
  • 2
    • 0025787935 scopus 로고
    • Active fixation leads-long term threshold reduction using a drug infused ceramic collar
    • Anderson N, Mathivanar R, Skalsky M, et al. Active fixation leads-long term threshold reduction using a drug infused ceramic collar. PACE 1991; 14: 1767-1771.
    • (1991) PACE , vol.14 , pp. 1767-1771
    • Anderson, N.1    Mathivanar, R.2    Skalsky, M.3
  • 3
    • 0022979946 scopus 로고
    • Time course of transvenous pacemaker stimulation impedance, capture threshold, and electrogram amplitude
    • Platia EV, Brinker JA. Time course of transvenous pacemaker stimulation impedance, capture threshold, and electrogram amplitude. PACE 1986; 9: 620-625.
    • (1986) PACE , vol.9 , pp. 620-625
    • Platia, E.V.1    Brinker, J.A.2
  • 4
    • 0023019041 scopus 로고
    • Clinical applications of pacing system analyzers and the Intermedics pacing system computer
    • Rottenberg WB, Carroll M, Reichenbach R. Clinical applications of pacing system analyzers and the Intermedics pacing system computer. Clin Prog Electrophysiol Pacing 1986; 4:460-468.
    • (1986) Clin Prog Electrophysiol Pacing , vol.4 , pp. 460-468
    • Rottenberg, W.B.1    Carroll, M.2    Reichenbach, R.3
  • 6
    • 9044235230 scopus 로고    scopus 로고
    • Personal communication with manufacturers. September, 1993
    • Personal communication with manufacturers. September, 1993.
  • 7
    • 0017540242 scopus 로고
    • Problems in measuring threshold for cardiac pacing
    • Preston TA, Barold SS. Problems in measuring threshold for cardiac pacing. Am J Cardiol 1977; 40: 658-660.
    • (1977) Am J Cardiol , vol.40 , pp. 658-660
    • Preston, T.A.1    Barold, S.S.2
  • 8
    • 0018414359 scopus 로고
    • Myocardial stimulation impedance: The effects of electrode, physiological, and stimulus variables
    • Tyers GFO, Brownlee RR, Hughes HC, et al. Myocardial stimulation impedance: the effects of electrode, physiological, and stimulus variables. Ann Thorac Surg 1979; 27:63-69.
    • (1979) Ann Thorac Surg , vol.27 , pp. 63-69
    • Tyers, G.F.O.1    Brownlee, R.R.2    Hughes, H.C.3
  • 9
    • 0025147911 scopus 로고
    • Ventricular cross stimulation in a dual chamber pacing system: Phenomenon analysis
    • Puglisi A, Ricci R, Azzolini P, et al. Ventricular cross stimulation in a dual chamber pacing system: Phenomenon analysis. PACE 1990; 13:993-1001.
    • (1990) PACE , vol.13 , pp. 993-1001
    • Puglisi, A.1    Ricci, R.2    Azzolini, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.