메뉴 건너뛰기




Volumn 51, Issue 6, 2006, Pages 1577-1593

Quantitative assessment of computed radiography quality control parameters

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING; LASER BEAMS; PARAMETER ESTIMATION; QUALITY CONTROL;

EID: 33644676949     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/6/015     Document Type: Article
Times cited : (19)

References (22)
  • 1
    • 33644685290 scopus 로고    scopus 로고
    • AAPM 2005 Assessment of Display Performance for Medical Imaging Systems Task Group 18 AAPM On-Line Report No. 03 http://www.aapm.org/pubs/reports/ public/OR_03.pdf
    • (2005) AAPM On-Line Report No. 03
    • Aapm1
  • 2
    • 33644672523 scopus 로고    scopus 로고
    • AGFA 1999 ADC compact auto QC software user manual Agfa-Gavaert N.V. 2217B GB 19991125
    • (1999) Agfa-Gavaert N.V.
    • Agfa1
  • 3
    • 0032932540 scopus 로고    scopus 로고
    • Performance characteristics of a Kodak computed radiography system
    • Bradford C D, Peppler W W and Dobbins J T 1999 Performance characteristics of a Kodak computed radiography system Med. Phys. 26 27-37
    • (1999) Med. Phys. , vol.26 , Issue.1 , pp. 27-37
    • Bradford, C.D.1    Peppler, W.W.2    Dobbins, J.T.3
  • 6
    • 33644683930 scopus 로고
    • Fuji 1993 Automatic setting functions for image density and range in the FCR system Technical Review No. 3 Fuji Photo Film Co. Ltd., Tokyo, Japan
    • (1993) Technical Review No. 3
    • Fuji1
  • 8
    • 25644445456 scopus 로고    scopus 로고
    • Speed values, AEC performance evaluation, and quality control with digital receptors
    • Goldman L W 2004 Speed values, AEC performance evaluation, and quality control with digital receptors Medical Physics Monograph No. 30 (Medical Physics Publishing) pp 271-97
    • (2004) Medical Physics Monograph No. 30 , pp. 271-297
    • Goldman, L.W.1
  • 10
    • 0031770493 scopus 로고    scopus 로고
    • A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates
    • Kengyelics S M, Davies A G and Cowen A R 1998 A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates Med. Phys. 25 2163-9
    • (1998) Med. Phys. , vol.25 , Issue.11 , pp. 2163-2169
    • Kengyelics, S.M.1    Davies, A.G.2    Cowen, A.R.3
  • 12
    • 0037341166 scopus 로고    scopus 로고
    • Automatic quantitative low contrast analysis of digital chest phantom radiographs
    • Kwan A L C, Filipow L J and Le L H 2003 Automatic quantitative low contrast analysis of digital chest phantom radiographs Med. Phys. 30 312-20
    • (2003) Med. Phys. , vol.30 , Issue.3 , pp. 312-320
    • Kwan, A.L.C.1    Filipow, L.J.2    Le L, H.3
  • 13
    • 0030720072 scopus 로고    scopus 로고
    • A method for quantifying SPECT uniformity
    • Masden M T 1997 A method for quantifying SPECT uniformity Med. Phys. 24 1696-700
    • (1997) Med. Phys. , vol.24 , Issue.11 , pp. 1696-1700
    • Masden, M.T.1
  • 16
    • 0037038876 scopus 로고    scopus 로고
    • The physics of computed radiography
    • Rowland J A 2002 The physics of computed radiography Phys. Med. Biol. 47 R123-66
    • (2002) Phys. Med. Biol. , vol.47
    • Rowland, J.A.1
  • 17
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • Samei E and Reimann D A 1997 A method for measuring the presampled MTF of digital radiographic systems using an edge test device Med. Phys. 25 102-13
    • (1997) Med. Phys. , vol.25 , Issue.1 , pp. 102-113
    • Samei, E.1    Reimann, D.A.2
  • 20
    • 0032800112 scopus 로고    scopus 로고
    • Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors
    • Stierstorfer K and Spahn M 1999 Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors Med. Phys. 26 1312-9
    • (1999) Med. Phys. , vol.26 , Issue.7 , pp. 1312-1319
    • Stierstorfer, K.1    Spahn, M.2
  • 21
    • 0030904476 scopus 로고    scopus 로고
    • The relationship between pixel value and beam quality in photostimulable phosphor imaging
    • Tucker D M and Rezentes P S 1997 The relationship between pixel value and beam quality in photostimulable phosphor imaging Med. Phys. 24 887-93
    • (1997) Med. Phys. , vol.24 , Issue.6 , pp. 887-893
    • Tucker, D.M.1    Rezentes, P.S.2
  • 22
    • 15944391372 scopus 로고    scopus 로고
    • The ALARA concept in pediatric CR and DR: Dose reduction in pediatric radiographic exams-a white paper conference
    • Willis C E and Slovis T L 2005 The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams-a white paper conference Am. J. Roentgenol. 184 373-4
    • (2005) Am. J. Roentgenol. , vol.184 , pp. 373-374
    • Willis, C.E.1    Slovis, T.L.2