메뉴 건너뛰기




Volumn , Issue , 2005, Pages 1289-1300

Effective dose ratios for tomographic and stylized models from external exposure to photons

Author keywords

Effective dose; Monte Carlo; Radiation protection; Voxel phantoms

Indexed keywords

BIOLOGICAL ORGANS; MONTE CARLO METHODS; PHOTONS; RADIATION PROTECTION; RADIOLOGY; TISSUE; TOMOGRAPHY;

EID: 33644591486     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (13)
  • 1
    • 0003733260 scopus 로고
    • ICRP 60, ICRP Publication 60, International Commission On Radiological Protection, Pergamon Press, Oxford
    • ICRP 60, "1990 Recommendations of the International Commission on Radiological Protection", ICRP Publication 60, International Commission On Radiological Protection, Pergamon Press, Oxford, (1991).
    • (1991) 1990 Recommendations of the International Commission on Radiological Protection
  • 2
    • 0003166807 scopus 로고
    • The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Part I: The male (Adam) and female (Eva) adult mathematical phantoms
    • Institut für Strahlenschutz, GSF-Forschungszentrum für Umwelt und Gesundheit, Neuherberg-Muenchen
    • KRAMER R, ZANKL M, WILLIAMS G and DREXLER G, "The Calculation of Dose from External Photon Exposures Using Reference Human Phantoms and Monte Carlo Methods. Part I: The Male (Adam) and Female (Eva) Adult Mathematical Phantoms". GSFReport S-885. Institut für Strahlenschutz, GSF-Forschungszentrum für Umwelt und Gesundheit, Neuherberg-Muenchen, (1982).
    • (1982) GSFReport , vol.S-885
    • Kramer, R.1    Zankl, M.2    Williams, G.3    Drexler, G.4
  • 4
    • 0038459031 scopus 로고    scopus 로고
    • All about MAX: A Male Adult voXel phantom for Monte Carlo calculations in radiation protection dosimetry
    • KRAMER R, VIEIRA J W, KHOURY H J, LIMA F R A and FUELLE D, "All About MAX: a Male Adult voXel Phantom for Monte Carlo Calculations in Radiation Protection Dosimetry", Phys. Med. Biol, 48, no. 10, 1239-1262, (2003).
    • (2003) Phys. Med. Biol , vol.48 , Issue.10 , pp. 1239-1262
    • Kramer, R.1    Vieira, J.W.2    Khoury, H.J.3    Lima, F.R.A.4    Fuelle, D.5
  • 5
    • 11044227792 scopus 로고    scopus 로고
    • All about FAX: A Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry
    • KRAMER R., VIEIRA J. W., KHOURY H. J., LIMA F. R. A., LOUREIRO E. C. M., LIMA V. J. M. and HOFF G., "All about FAX: a Female Adult voXel Phantom for Monte Carlo Calculation in Radiation Protection Dosimetry", Phys. Med. Biol. 49, 5203-5216, (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 5203-5216
    • Kramer, R.1    Vieira, J.W.2    Khoury, H.J.3    Lima, F.R.A.4    Loureiro, E.C.M.5    Lima, V.J.M.6    Hoff, G.7
  • 8
    • 0003444170 scopus 로고
    • ICRP 23, ICRP publication 23, International Commission on Radiological Protection, Pergamon Press, Oxford
    • ICRP 23, "Report of the Task Group on Reference Man", ICRP publication 23, International Commission on Radiological Protection, Pergamon Press, Oxford, (1975).
    • (1975) Report of the Task Group on Reference Man
  • 9
    • 0003620648 scopus 로고
    • SLAC-265 Stanford Linear Accelerator Center, Stanford University, Stanford, California
    • NELSON W R, HIRAYAMA H and ROGERS D W O, "The EGS4 Code System". SLAC-265 Stanford Linear Accelerator Center, Stanford University, Stanford, California, (1985).
    • (1985) The EGS4 Code System.
    • Nelson, W.R.1    Hirayama, H.2    Rogers, D.W.O.3
  • 11
    • 84907513176 scopus 로고
    • Tissue substitutes in radiation dosimetry and measurement
    • ICRU 44. International Commission On Radiation Units And Measurements, Bethesda, MD
    • ICRU 44, "Tissue Substitutes in Radiation Dosimetry and Measurement". ICRU Report 44. International Commission On Radiation Units And Measurements, Bethesda, MD, (1989).
    • (1989) ICRU Report , vol.44
  • 12
    • 0003598546 scopus 로고    scopus 로고
    • The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Part VII: Organ doses due to parallel and environmental exposure geometries
    • Institut für Strahlenschutz, GSF-Forschungszentrum für Umwelt und Gesundheit, München-Neuherberg
    • ZANKL M, DREXLER G, PETOUSSI-HENSS N and SAITO K, "The Calculation of Dose from External Photon Exposures Using Reference Human Phantoms and Monte Carlo Methods. Part VII: Organ Doses Due to Parallel and Environmental Exposure Geometries". GSF-Report 8/97. Institut für Strahlenschutz, GSF-Forschungszentrum für Umwelt und Gesundheit, München-Neuherberg, (1997).
    • (1997) GSF-Report , vol.8 , Issue.97
    • Zankl, M.1    Drexler, G.2    Petoussi-Henss, N.3    Saito, K.4
  • 13
    • 1642487114 scopus 로고    scopus 로고
    • MAX meets ADAM: A dosimetric comparison between a voxel-based and a mathematical model for external exposures to photons
    • KRAMER R, VIEIRA J W, KHOURY H J and LIMA F R A, "MAX meets ADAM: a Dosimetric Comparison Between a Voxel-Based and a Mathematical Model for External Exposures to Photons", Phys. Med. Biol., 49, 887-910, (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 887-910
    • Kramer, R.1    Vieira, J.W.2    Khoury, H.J.3    Lima, F.R.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.